First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
Denis Bourgeois's profile - overview
overview
network
karma
followed questions
activity
2,831
karma
follow
Registered User
member since
2020-09-18 09:55:34 -0500
last seen
2024-10-30 09:30:42 -0500
website
http://www.rd2.ca
location
Québec,
todays unused votes
30
votes left
2
Questions
528
views
1
answer
10
votes
2022-06-12 18:06:10 -0500
Denis Bourgeois
... on (major) thermal bridging and derating of surface constructions
thermal-bridge
openstudio-measure
envelope
279
views
no
answers
3
votes
2023-10-03 12:38:27 -0500
Denis Bourgeois
… 90.1 2022 requirements for linear thermal bridges
thermal-bridge
tbd
ashrae-90.1
ecb
heat-transfer
155
Answers
5
Two Different construction for one wall ?
5
How do you start OpenStudio Application on Mac OS X?
5
U-Value for Simple Glazing in OpenStudio Results
4
How to consider the impact of shading devices on ventilation?
4
Where can I find the material RoofVegetation in OpenStudio?
4
Seasonal thermostat setpoints / EnergyPlus
4
... on (major) thermal bridging and derating of surface constructions
4
State of Practice for Thermal Bridges
3
OS: Retrieve/edit ZoneHVACIdealLoadsAirSystem from thermal zone
3
OpenStudio: Set UnitConversion to JtoKWH when generating idf
« previous
1
...
1
2
3
4
5
...
16
next »
515
Votes
515
0
50
Tags
energyplus
× 239
openstudio
× 203
openstudio-application
× 123
geometry
× 51
openstudio-measure
× 49
construction
× 44
openstudio-sdk
× 33
severe-error
× 30
sketchup
× 27
error
× 24
openstudio-ske...
× 23
installation
× 18
output-variable
× 18
thermostat
× 17
thermal-bridge
× 17
ground-heat-transfer
× 16
ashrae-90.1
× 14
swimming-pool
× 13
designbuilder
× 13
material
× 13
photovoltaic
× 13
mac-os
× 12
warning
× 12
window
× 12
interior-wall
× 12
ground-temperature
× 12
heat-transfer
× 12
energy-consumption
× 12
natural-ventilation
× 11
shading
× 11
hvac-control
× 11
heating-load
× 11
energy-loads
× 11
output-report
× 10
solar-radiation
× 10
floorspace.js
× 10
application-error
× 10
commercial-pro...
× 10
plant-loop
× 9
surface
× 9
insulation
× 9
parametric-analysis
× 9
baseline
× 9
grid
× 9
building-envelope
× 9
appendix-g
× 8
cooling-load
× 8
energyplus-exa...
× 8
air-wall
× 8
air-source-heat-pump
× 8
12
Badges
●
Scholar
×
1
... on (major) thermal bridging and derating of surface constructions
●
Enthusiast
×
1
●
Student
×
1
... on (major) thermal bridging and derating of surface constructions
●
Associate Editor
×
1
AirChanges/Hour in EnergyPlus
●
Commentator
×
1
What's the best way to add thermal bridges in OpenStudio?
●
Nice Question
×
1
... on (major) thermal bridging and derating of surface constructions
●
Self-Learner
×
1
... on (major) thermal bridging and derating of surface constructions
●
Teacher
×
1
How does EnergyPlus receive shortwave radiation values for the exterior energy balance?
●
Rapid Responder
×
102
How does EnergyPlus receive shortwave radiation values for the exterior energy balance?
EnergyPlus Model Library
How to enable air stratification in EnergyPlus?
Does thermal emissivity and solar absorptance matter for all layers?
How to get all OS objects and their members?
How to model daylighting control in pilotis
Finding R-values of constructions in OpenStudio
How to simulate a certain floor of a building
State of Practice for Thermal Bridges
U-Value for Simple Glazing in OpenStudio Results
Ground coupling - small building floor slab
Issue with internal source construction in OpenStudio
Openfoam wind pressure coefficients values with Openstudio?
How to add "Air wall" in open studio?
How do I view results on mac
How to use EnergyPlus to model a neighborhood (several buildings)?
ASHRAE 90.1 Addenda enforcement
I am trying to model a framed wall. can anyone please explain how this type of wall is modeled in energyplus? please see attached pic for reference. This is a traditional wall found in the Himalayan region made of stone, rubble and wooden frames.
Cannot compute outward normal for vertices surface
CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.
Ground slab insulation studies for commercial buildings?
How OpenStudio works with U-factor, R-value, thermal bridges?
Why ZoneHVAC:Baseboard:RadiantConvective:Water has an air loop?
Some beginner's doubts
Will EnergyPlus update the heat flow values of building envelopes when changing their R-values?
Suelo radiante en OpenStudio (Radiant floor in OpenStudio)
not fully enclosed and heating load
This sub surface was not in the same plane as its base surface.
Inconsistent crash without error log
Check convexity, surface is non-convex? interzone surface area and same number of layers
negative zone volume and Total wall area by ASHRAE 90.1 definition
LS-D vs SS-D vs SV-A reports in equest
Energyplus retrieving instantaneous energy consumption
What is the solution for the openstudio error for cogeneration measure fail
Open Studio Ruby code - getting the existing HVAC air loop template
User Defined Plant Maximum Loading Capacity Override
invalid blank Outside Boundary Condition Object
I need to find correct vertex and starting coordinates values
Question about the relation between Number of people and multipliers
How to Set a Building Story Default Construction Set to None
Effect of No Mass Materials
Defining thermal Zones
Can i draw different ceiling height in the same floor on openstudio application?
Add blinds to open studio
natural ventilation in ECB
AirChanges/Hour in EnergyPlus
Assembly U-factor, SHGC and VT are not calculated correctly
How do you start OpenStudio Application on Mac OS X?
change the solar absorptance of roof outermost layer based on outdoor dry bulb temperature
Basic drawing problem
Zone air supply temperature
Defining solar power / solar heat flux
openstudio-sketchup-plugin
Indoor Swimming Pool temperature
Creating multiple zones when importing gbxml file in openstudio
Add photovoltaics inside OpenStudio
Error with consumptions and outside temperature
transfer surplus electricity in the house to power grid
Error after importing EnergyPlus Example IDF into OSM
Could someone please send me an openstudio (.osm) file including building energy measurement parameters?
defining 'setback temperature' for HVAC
Heat pipe system OpenStudio
Heat gain and heat loss by time of day from windows in each room of the house
Two Different construction for one wall ?
Horizontal ground heat exchanger
Can I reinstall OpenStudio?
HVAC Systems - Radiant Floor
Where can I find the installed OpenStudio in my computer?
Seasonal thermostat setpoints / EnergyPlus
Some questions about error about schedule
Can i use Ems to change the area of a fenestration or a transmittance of a glazing material during the calculation process?
What are the solutions for modeling natural ventilation in summer?
Unclear GitHub page OpenStudio
Boundary Conditions with above floors
The surface has an edge that is either not an edge on another surface or is an edge on three or more surfaces
How to solve "ProcessScheduleInput: ..." problems?
Modeling Adjacent Walls with Different Materials
Why do I get 'Cooling Design Supply Air Temperature=[25.00]' and 'Heating Design Supply Air Temperature=[20.00]' severe errors? ?
What is the solution to the SWIG error in this simulation run? I tried adding two measures Add Meter and ExportMetertoCSV.
How to consider the impact of shading devices on ventilation?
How do we define the shading impact of adjacent buildings on the building of interest in EnergyPlus/OpenStudio?
How do I incorporate a green wall into my model, using OpenStudio?
Any idea why these errors show up when I load my .osm file?
where is the default contruction?
is OpenStudio BPI 1200 and/or BPI 2400 compliant?
Where are Example Files?
how to check idf geometry and construction
Scheduled %RH with simple HVAC settings? (DesignBuilder)
water use equipment space OS-3.7.0 vs. OSApp-1.7.0
OpenStudio: Set UnitConversion to JtoKWH when generating idf
AllSummaryAndSizingPeriod Measure
Ground Heat Exchanger Simulation Issue in OpenStudio Model Version Discrepancy
Simulation failed to run, with exit code 1, please help , i have been getting this error.
json files of DOE prototype buildings in open studio?
Problem with Open Studio results, zone air temperature
Error "EnergyPlus returned a non-zero exit code (1). Check the stdout-energyplus log"
How can I model a hot water radiator in OpenStudio?
a gap between two zones or with the shade surface
where did my OS toolbar go on SketchUP?
Why does my simulation show error "Polyhedron is not enclosed in original testing. Trying to add missing colinear points."
OS: Retrieve/edit ZoneHVACIdealLoadsAirSystem from thermal zone
Determine "Effective thickness of cavity behind exterior baffle"
●
Civic Duty
×
1
Time of Peak is not in Timestep increments
●
Supporter
×
1
Difference of n50 and infiltration rate
●
Editor
×
1
... on (major) thermal bridging and derating of surface constructions
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how