First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get s tarted with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
xchen's profile - overview
overview
network
karma
followed questions
activity
743
karma
follow
Registered User
member since
2015-04-16 15:55:09 -0600
last seen
2021-01-14 10:42:28 -0600
location
United States of America
todays unused votes
30
votes left
31
Questions
527
views
1
answer
8
votes
2016-12-20 12:07:10 -0600
Eric Ringold
why is 90.1 Appendix G Baseline one system per floor
ashrae-90.1
appendix-g
hvac
544
views
3
answers
6
votes
2015-10-27 19:30:32 -0600
xchen
good tools for viewing energyplus output htm file
energyplus
output-report
63
views
no
answers
5
votes
2018-04-23 19:38:44 -0600
xchen
AedgK12SlabAndBasement measure not working
openstudio-measure
slab
ground-heat-transfer
aedg
151
views
1
answer
3
votes
2019-08-26 19:56:50 -0600
xchen
return air node enthalpy not matching plenum enthalpy
openstudio
output-variable
plenum
return-air
163
views
no
answers
3
votes
2018-06-15 18:21:42 -0600
xchen
radiant slab modeling w/ ground heat transfer
low-temperature-radiant
openstudio
slab
209
views
1
answer
3
votes
2020-07-22 11:49:31 -0600
David Goldwasser
openstudio space level schedule set not overwriting space type template
openstudio
space-type
internal-load
89
views
no
answers
2
votes
2019-05-08 20:32:16 -0600
xchen
VAV system supply air ACH setting with nighttime setback
openstudio
81
views
no
answers
2
votes
2019-02-19 12:40:19 -0600
shorowit
error removing four pipe active beams in os v26 and v27
openstudio
error
please-use-existing-tags
384
views
2
answers
2
votes
2017-09-02 09:46:34 -0600
GregWard
bsdf file and actual geometry
bsdf
radiance
daylighting
367
views
no
answers
2
votes
2019-03-25 13:46:05 -0600
xchen
AirLoop Component Sizing peak condition numbers
openstudio
energyplus
load-calculation
system-sizing
« previous
1
...
1
2
3
4
...
4
next »
6
Answers
3
good tools for viewing energyplus output htm file
2
"NR SBD Performance" calculation in Energy Pro
2
CBECC EnergyPlus Error in the Baseline, "Rated air volume flow rate per watt of rated total cooling capacity is out of range"
1
central heat pump heating and cooling energy all 0
1
return air node enthalpy not matching plenum enthalpy
1
Is there any way to set the actual supply air temperature hourly for FCU and OA?
16
Votes
16
0
50
Tags
openstudio
× 42
openstudio-measure
× 22
energyplus
× 21
cbecc-com
× 10
radiance
× 7
error
× 6
output-report
× 6
energypro
× 5
weather-file
× 5
sketchup2015
× 4
induction-terminal
× 4
hvac
× 3
doas
× 3
appendix-g
× 3
daylighting
× 3
code-compliance
× 3
ashrae-90.1
× 3
bsdf
× 3
space-type
× 3
internal-load
× 3
fan-coil-unit
× 3
heat-recovery-chiller
× 3
simulation-time
× 2
equest
× 2
ies-ve
× 2
slab
× 2
title-24
× 2
output-variable
× 2
plenum
× 2
elevator
× 2
batch-run
× 2
chiller-heater
× 2
return-air
× 2
savings-by-design
× 2
aedg
× 1
outdoor-air
× 1
fan
× 1
mechanical-ventilation
× 1
designbuilder
× 1
air-mixing
× 1
low-temperatur...
× 1
hvac-control
× 1
system-sizing
× 1
timestep
× 1
ashrae-62.1
× 1
ground-heat-transfer
× 1
load-calculation
× 1
daylighting-control
× 1
shading-control
× 1
please-use-exi...
× 1
8
Badges
●
Self-Learner
×
1
good tools for viewing energyplus output htm file
●
Scholar
×
1
openstudio sketchup plugin .skp model reopen
●
Supporter
×
1
Simulation period with measured Data
●
Enthusiast
×
1
●
Teacher
×
1
good tools for viewing energyplus output htm file
●
Critic
×
1
How to evaluate indoor comfort
●
Student
×
1
CBECC-Com DOAS dummy zone surface temperature out of bounds
●
Commentator
×
1
why is 90.1 Appendix G Baseline one system per floor
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how