First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
katsuya.obara's profile - overview
overview
network
karma
followed questions
activity
2,085
karma
follow
Registered User
real name
katsuya obara
member since
2017-03-09 21:35:41 -0600
last seen
2022-05-22 22:18:07 -0600
location
Fukuoka, Japan
age, years
36
todays unused votes
30
votes left
93
Questions
1k
views
1
answer
7
votes
2017-08-22 03:06:16 -0600
Julien Marrec
Why chiller operate below minimum Part Load Ratio?
energyplus
chiller
650
views
1
answer
6
votes
2017-10-26 11:21:05 -0600
MJWitte
How maximum outdoor air flow rate is calculated in Controller:OutdoorAir?
energyplus
outdoor-air
air-flow
1k
views
1
answer
5
votes
2024-03-04 13:16:16 -0600
shorowit
Can we use epjson as input file to run energy simulation?
epjson
energyplus
521
views
1
answer
5
votes
2017-09-29 07:43:47 -0600
rraustad
VRF system shows high COP compared to specified COP
energyplus
vrf
39k
views
2
answers
5
votes
2017-11-25 11:44:12 -0600
aparker
Sequential load distribution scheme seems not working
energyplus
chiller
plant-equipment-operation
1k
views
1
answer
5
votes
2023-03-31 12:12:28 -0600
Keigo
Any way to open idf file without getting Out of memory error?
idf-editor
idd-file
energyplus
designbuilder
application-error
538
views
1
answer
4
votes
2018-08-23 14:38:12 -0600
taher.ahel
Cooling Tower is storing excess heat the majority of the time
energyplus
136
views
1
answer
3
votes
2020-03-06 09:19:07 -0600
Luis Lara
Any equivalent data with Annual peak cooling load in hourly data
ideal-loads-air-system
energyplus
508
views
2
answers
3
votes
2020-01-18 14:12:38 -0600
santoshphilip
Use Eppy to remove specified parameter
energyplus
eppy
684
views
no
answers
3
votes
2018-01-03 05:25:56 -0600
katsuya.obara
hot water system with heat pump and solar thermal
openstudio
service-hot-water
solar-thermal
solar-collector
« previous
1
...
1
2
3
4
5
...
10
next »
3
Answers
3
Why having unmet hour even though capacity is enough for VRF system?
2
Plant loop is not operated
1
DCV doesn't work [OA introduction doesn't decrease according to people occupant]
768
Votes
768
0
50
Tags
energyplus
× 91
openstudio
× 33
openstudio-measure
× 20
outdoor-air
× 15
chiller
× 9
plant-loop
× 8
dcv
× 7
cooling-tower
× 7
surface-matching
× 6
fan-coil-unit
× 6
plant-equipmen...
× 6
vrf
× 5
surface-intersecting
× 5
air-flow
× 4
eppy
× 4
ems
× 4
hvac-template
× 4
openstudio-standards
× 4
hvac
× 3
performance-curve
× 3
geometry
× 3
leed
× 3
vav
× 3
surface
× 3
pump
× 3
air-loop
× 3
availability-schedule
× 3
window
× 3
openstudio-sdk
× 3
electric-equipment
× 3
openstudio-cli
× 3
workflow
× 2
doas
× 2
lighting
× 2
unmet-hours
× 2
honeybee
× 2
designbuilder
× 2
output-report
× 2
economizer
× 2
setpoint-manager
× 2
district-cooling
× 2
osw-file
× 2
non-ascii-character
× 2
natural-ventilation
× 1
cooling-coil
× 1
ies-ve
× 1
appendix-g
× 1
sketchup
× 1
ashrae-90.1
× 1
heat-pump
× 1
12
Badges
●
Famous Question
×
1
Sequential load distribution scheme seems not working
●
Supporter
×
1
HVAC library missing in OS since updated to v2.1
●
Commentator
×
1
VAV doesn't introduce any OA once DCV is implemented
●
Enthusiast
×
1
●
Scholar
×
1
How the chiller performance curve affect to plant sizing calculation
●
Civic Duty
×
1
How to batch baseline models automatically?
●
Popular Question
×
7
Energy simulation without geometry
Sequential load distribution scheme seems not working
What could be the reason why terminal unit reduce cooling even though the zone cannot meet setpoint?
HVACTemplate:VAV doesn't introduce Outdoor Air
Any way to open idf file without getting Out of memory error?
Why chiller operate below minimum Part Load Ratio?
Can we use epjson as input file to run energy simulation?
●
Self-Learner
×
1
Why having unmet hour even though capacity is enough for VRF system?
●
Notable Question
×
2
What could be the reason why terminal unit reduce cooling even though the zone cannot meet setpoint?
Sequential load distribution scheme seems not working
●
Editor
×
1
VAV doesn't introduce any OA once DCV is implemented
●
Student
×
1
Failed simulation without getting severe / fatal error
●
Teacher
×
1
Plant loop is not operated
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how