First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
Debayan93's profile - overview
overview
network
karma
followed questions
activity
121
karma
follow
Registered User
member since
2021-05-03 04:36:42 -0600
last seen
2023-02-23 09:33:57 -0600
todays unused votes
30
votes left
15
Questions
473
views
1
answer
2
votes
2021-05-25 12:11:09 -0600
Debayan93
Swapping Unitary Water cooling coil with the DX coil
designbuilder
dehumidification
humidity-control
dx-coil
air-handling-unit
109
views
no
answers
1
vote
2022-02-14 13:22:45 -0600
Debayan93
Undersizing HVAC templates based on autosized values [closed]
energyplus
designbuilder
autosizing
hvac
hvac-sizing
185
views
1
answer
1
vote
2022-12-14 16:32:40 -0600
santoshphilip
Running Eppy (E+) on a web server
eppy
geomeppy
energyplus
server
website
301
views
1
answer
1
vote
2021-05-03 11:00:25 -0600
Debayan93
Setting different heating/cooling setpoint temperatures and humidification/dehumification setpoints over the year
designbuilder
humidity-control
setpoint
setpoint-manager
140
views
1
answer
1
vote
2021-09-08 09:18:25 -0600
rraustad
Humidistat controlled heating (Conservation Heating)
designbuilder
humidity-control
setpoint
99
views
no
answers
1
vote
2021-05-09 14:12:42 -0600
Debayan93
Understanding of energy consumption and corresponding utility [closed]
designbuilder
heating-system
vav
air-handling-unit
1k
views
1
answer
1
vote
2021-07-22 02:08:15 -0600
Debayan93
Relative Humidity control in DesignBuilder
designbuilder
humidity-control
dehumidifier
hvac-template
humidification
186
views
no
answers
1
vote
2022-03-20 13:58:53 -0600
Debayan93
How to model a green facade in DesignBuilder
green-facade
green-roof
designbuilder
energyplus
revit
278
views
no
answers
1
vote
2022-07-04 14:20:51 -0600
Debayan93
Dehumidification issue (Water Cooled System, DesignBuilder)
designbuilder
dehumidification
humidity-control
autosizing
water-cooled-chiller
83
views
1
answer
1
vote
2022-02-21 10:01:05 -0600
Debayan93
Extremely high HVAC nominal capacity than hourly loads [closed]
designbuilder
energyplus
hvac
autosizing
hvac-load
« previous
1
...
1
2
...
2
next »
1
Answer
0
Solar Irradiance [TMY vs Actual data]
0
Votes
0
0
49
Tags
designbuilder
× 27
energyplus
× 12
humidity-control
× 12
autosizing
× 7
hvac
× 6
dehumidification
× 5
eppy
× 4
setpoint
× 4
humidification
× 4
hvac-template
× 4
dehumidifier
× 4
hvac-load
× 4
output-report
× 3
output-variable
× 3
setpoint-manager
× 3
air-handling-unit
× 3
dx-coil
× 3
infiltration
× 2
ventilation
× 2
cooling
× 2
mechanical-ventilation
× 2
air-loop
× 2
energyplus-wea...
× 2
weather-file
× 2
solar-radiation
× 2
water-cooled-chiller
× 2
sizing
× 1
unmet-hours
× 1
vav
× 1
python
× 1
revit
× 1
schedule
× 1
ems
× 1
thermostat
× 1
heating-system
× 1
heating-load
× 1
cooling-load
× 1
zone-hvac
× 1
hvac-sizing
× 1
website
× 1
solar-collector
× 1
heating
× 1
green-roof
× 1
geomeppy
× 1
ahu
× 1
level-of-detail
× 1
server
× 1
dhw
× 1
green-facade
× 1
6
Badges
●
Enthusiast
×
1
●
Popular Question
×
1
Relative Humidity control in DesignBuilder
●
Editor
×
1
Swapping Unitary Water cooling coil with the DX coil
●
Commentator
×
1
Extremely high HVAC nominal capacity than hourly loads
●
Organizer
×
1
Humidistat controlled heating (Conservation Heating)
●
Student
×
1
Setting different heating/cooling setpoint temperatures and humidification/dehumification setpoints over the year
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how