First time here? Check out the Help page!
2021-03-25 17:18:20 -0500 | received badge | ● Popular Question (source) |
2018-03-14 11:23:57 -0500 | commented answer | Warehouse space conditioned by fans - always on Thanks so much! |
2018-03-14 11:23:38 -0500 | marked best answer | Warehouse space conditioned by fans - always on Hello, This is a follow up to my previous post here I am trying to model an unconditioned warehouse space (no mechanical cooling, only fans combined with interlocked sidewall louvers). The fans are upblast fans and have a total combined capacity of 900,000 cfm (louvers on the sidewalls allow outside air back into the facility). These fans are constant volume and always on regardless of temperature. The issue I was running into following @Avi 's suggestion was I would get an error along the lines of "Severe * CalcMixedAirSetPoint: Missing reference temperature setpoint for Mixed Air Setpoint Manager " if I only used a mass flow setpoint manager and not a temperature set point. |
2018-03-14 11:23:38 -0500 | received badge | ● Scholar (source) |
2018-03-14 09:00:12 -0500 | commented answer | Warehouse space conditioned by fans - always on @avi, I really appreciate you taking a look. Two follow up questions: 1. How do I delete the setpoint manager?, and 2. D |
2018-03-13 08:42:06 -0500 | commented question | Warehouse space conditioned by fans - always on Strange, give this one a try |
2018-03-12 13:33:36 -0500 | commented question | Warehouse space conditioned by fans - always on @Avi, sure here is a dropbox link to the model (https://www.dropbox.com/s/5lg0wnr3elx...) Let me know if there is a bett |
2018-03-12 13:33:24 -0500 | answered a question | Warehouse space conditioned by fans - always on @avi, sure here is a dropbox link to the model (https://www.dropbox.com/s/5lg0wnr3elx59qf/Unmethours%20Model%20-%20pksmi |
2018-03-08 15:47:24 -0500 | asked a question | Warehouse space conditioned by fans - always on Warehouse space conditioned by fans - always on Hello, This is a follow up to my previous post here I am trying to mo |
2018-03-05 09:31:49 -0500 | commented answer | Modeling Warehouse With Only Fans @Avi, I have a question for you. When I run my model and have the setpoint manager control variable set to 'Mass Flow Ra |
2018-03-05 09:31:12 -0500 | commented answer | Modeling Warehouse With Only Fans @Avi, I have a question for you. When I run my model and have the setpoint manager control variable set to 'Mass Flow Ra |
2018-02-26 14:01:52 -0500 | commented answer | How to export graph from openstudio to excel? @David Goldwasser, does this provide the underlying data that was used to create the graphs? I'm after calculating the W |
2018-02-26 13:51:00 -0500 | commented answer | How to export graph from openstudio to excel? @David Goldwasser, does this provide the underlying data that was used to create the graphs? I'm after calculating the W |
2018-02-26 13:50:41 -0500 | commented answer | How to export graph from openstudio to excel? David, does this provide the underlying data that was used to create the graphs? I'm after calculating the WBGT for the |
2018-02-26 12:03:32 -0500 | received badge | ● Supporter (source) |
2018-02-26 12:03:05 -0500 | commented answer | How to export graph from openstudio to excel? I am trying to figure out the same thing, did you have any luck? |
2018-02-21 09:35:03 -0500 | commented answer | Modeling Warehouse With Only Fans Avi, thank you so much for your help and detailed response! I will give that a try and let you know if that works for my |
2018-02-17 10:55:10 -0500 | received badge | ● Student (source) |
2018-02-16 14:09:07 -0500 | asked a question | Modeling Warehouse With Only Fans Modeling Warehouse With Only Fans Hello, I am new to openstudio/energy plus. I am working on modeling a warehouse that i |