2022-03-01 14:01:02 -0500 | received badge | ● Popular Question (source) |
2019-06-23 10:51:49 -0500 | edited question | Simple AHU EnergyPlus Simple AHU EnergyPlus I'm quite new to Air systems in EnergyPlus and I'm trying to model a simple AHU, that should guara |
2019-06-23 04:24:11 -0500 | asked a question | Simple AHU EnergyPlus Simple AHU EnergyPlus I'm quite new to Air systems in EnergyPlus and I'm trying to model a simple AHU, that should guara |
2019-06-19 09:07:54 -0500 | edited question | LoadProfile:Plant in AirLoopHVAC LoadProfile:Plant in AirLoopHVAC Is it possible to use a LoadProfile:Plant object on the demand side of an AirLoopHVAC, |
2019-06-19 09:07:13 -0500 | asked a question | LoadProfile:Plant in AirLoopHVAC LoadProfile:Plant in AirLoopHVAC Is it possible to use a LoadProfile:Plant object on the demand side of an AirLoopHVAC, |
2018-12-04 10:38:30 -0500 | commented question | How can i create a jEPlus+EA project (project.jep file) and how to update an idf file? You need first to open jEPlus, load your idf, epw and rvx files, save the project as a .jep file, then open jEPlus+EA an |
2018-11-29 09:31:47 -0500 | received badge | ● Commentator |
2018-11-29 09:31:47 -0500 | commented question | how to perform multi-objective optimization with jEPlus? Did you have a look at jEPlus+EA? It's a tool where you input a jEPlus parametric model and it performs multi-objective |
2018-07-11 03:11:54 -0500 | commented question | Parametrics EnergyPlus? I think the question here is not about parametric or sensitivity analysis, but it is about how to parametrize input vari |
2018-07-11 02:50:32 -0500 | marked best answer | Air Loop Heating Load is zero I'm trying to get confidence with the AirLoopHVAC system (E+ 8.8), before applying it to complex models, so I built a simple 2 zone building, with an air loop served by a boiler and chiller, to supply conditioned air to both zones. You can find the model here. The heating load (as well as the autosized values for the hot water loop) is always zero. Probably there is some mistake in the setpoint definition. I checked the InputOutput and example files to see what kind of error I'm doing, but I couldn't find it. If anyone could have a look at it, it would be very helpful. |
2018-07-02 04:52:25 -0500 | marked best answer | How to include weather related objects in my parametric E+ model? I'm building a parametric E+ simulation using jEPlus. I want to include in each idf some weather-related objects (e.g. I want to change the HVAC availability schedule, depending on which weather file is used for that simulation). Any hints for doing that? Better using EPMacro or a python code? |
2018-07-02 04:44:57 -0500 | asked a question | Air Loop Heating Load is zero Air Loop Heating Load is zero I'm trying to get confidence with the AirLoopHVAC system (E+ 8.8), before applying it to c |
2018-07-02 04:03:51 -0500 | marked best answer | Adjacent heated zones in EP The building I'm modelling in EnergyPlus is adjacent to other heated buildings. I modeled the other buildings, as adjacent thermal zones (Net part of total floor area set to No in the Zone object), conditioned by an ideal air system. When I check the results, I see the consumption of the ideal air system included in the total consumption of my building. Is there a way to exclude it from total consumption, just like I am able to exclude its area from total building area? Or, would you better recommend to model it using Other Side Coefficients as boundary conditions? Update 01/04: I still have no solution of that problem. I need to model the adjacent zones as actual zones because I have internal windows to be taken into account. However I am still not able to exclude the energy consumption of the other zones from that of my building in the final report. Any suggestion would be highly appreciated. |
2018-07-02 04:03:51 -0500 | received badge | ● Scholar (source) |
2018-07-02 04:01:54 -0500 | received badge | ● Autobiographer |
2018-02-12 04:25:55 -0500 | answered a question | glass door in energy plus euclid There are 2 ways to model subsurfaces in E+: simplified and detailed. For the detailed mode you will use the Fenestratio |
2018-02-09 02:48:50 -0500 | received badge | ● Enthusiast |
2018-02-07 04:43:41 -0500 | answered a question | Guide/tutorial to prepare a thermal building geometry by sketchup to measure the inner temperature. I will assume you are going to use EnergyPlus or Open Studio for this model (please specify it). To build your geometry |
2018-02-05 09:35:55 -0500 | answered a question | using python code in E+ You can't insert python code in the E+ model, it's the reverse: you use python to edit the idf file and then call the E+ |
2018-01-29 02:48:47 -0500 | commented answer | Cooling tower outlet temperature error Thank you, I will check that out. |
2018-01-27 05:40:59 -0500 | edited question | On/off chillers EnergyPlus On/off chillers EnergyPlus I'm modelling a chilled water loop with EnergyPlus. I used WaterUse:Equipment to model the ch |
2018-01-27 04:54:13 -0500 | commented question | Cooling tower outlet temperature error I added the temperature plot. Shouldn't I expect the inlet and outlet temperature of the cooling tower to be independent |
2018-01-27 04:52:09 -0500 | edited question | Cooling tower outlet temperature error Cooling tower outlet temperature error I'm modelling a water cooled chiller loop in EnergyPlus. I set the cooling tower |
2018-01-26 09:36:00 -0500 | asked a question | Cooling tower outlet temperature error Cooling tower outlet temperature error I'm modelling a water cooled chiller loop in EnergyPlus. I set the cooling tower |
2018-01-24 10:58:47 -0500 | commented answer | On/off chillers EnergyPlus Thank you! Indeed I had to force mains water temperature with a schedule to close the cycle, but with LoadProfile it's m |
2018-01-24 06:13:19 -0500 | asked a question | On/off chillers EnergyPlus On/off chillers EnergyPlus I'm modelling a chilled water loop with EnergyPlus. I used WaterUse:Equipment to model the ch |
2018-01-19 07:58:22 -0500 | received badge | ● Supporter (source) |
2018-01-05 02:45:39 -0500 | commented answer | Adjacent heated zones in EP Ok so I need to subtract it. I was just hoping to find a way to do it in the input phase, without any post-processing. I |
2018-01-04 10:32:00 -0500 | edited question | Adjacent heated zones in EP Adjacent heated zones in EP The building I'm modelling in EnergyPlus is adjacent to other heated buildings. I modeled th |
2017-12-11 04:20:52 -0500 | answered a question | determining heating and cooling in peak conditions You can do both with one simulation, just adding 2 SizingPeriod:DesignDay objects, one for winter and one for summer. Th |
2017-12-11 03:55:31 -0500 | asked a question | Adjacent heated zones in EP Adjacent heated zones in EP The building I'm modelling in EnergyPlus is adjacent to other heated buildings. I modeled th |
2017-12-01 08:46:06 -0500 | received badge | ● Teacher (source) |
2017-12-01 07:44:25 -0500 | edited answer | How to include weather related objects in my parametric E+ model? Just in case someone will need it, I solved the problem in this way: I wrote a python script (as suggested by Yi Zhang), |
2017-12-01 06:01:30 -0500 | edited answer | How to include weather related objects in my parametric E+ model? Just in case someone will need it, I solved the problem in this way: I wrote a python script (as suggested by Yi Zhang), |
2017-12-01 06:01:30 -0500 | received badge | ● Editor (source) |
2017-12-01 06:00:54 -0500 | answered a question | How to include weather related objects in my parametric E+ model? Just in case someone will need it, I solved the problem in this way: I wrote a python script (as suggested by Yi Zhang), |
2017-12-01 04:34:44 -0500 | commented question | How to include weather related objects in my parametric E+ model? I'm going to try that. Thanks for your help! |
2017-11-30 06:01:06 -0500 | commented question | How to include weather related objects in my parametric E+ model? As for now they are static group of objects. I was thinking that Python should read the job name and, depending on the n |
2017-11-29 10:50:52 -0500 | commented question | How to include weather related objects in my parametric E+ model? Doing it maually is definitely an option (I just have 3-5 different climates, each one having a related group of objects |
2017-11-28 07:36:29 -0500 | asked a question | How to include weather related objects in my parametric E+ model? How to include weather related objects in my parametric E+ model? Hi all! I'm building a parametric E+ simulation using |
2017-11-27 04:19:23 -0500 | answered a question | How to calculate the heat flux from boundaries in E+ Have you tried with Output:Variable "Surface Inside Face Conduction Heat Transfer Rate" ? |
2017-11-24 11:51:12 -0500 | commented question | Error with thermostatic control EnergyPlus8.8 No, I'm using a VRF air to air heat pump (reference example file: DOASDXCOIL_wADPBFMethod.idf ). I get the same error in |
2017-11-24 11:16:43 -0500 | edited question | Error with thermostatic control EnergyPlus8.8 Error with thermostatic control EnergyPlus8.8 I'm having a bit of a problem in thermostatic control of a Heat Pump (Ener |
2017-11-24 08:49:56 -0500 | received badge | ● Student (source) |
2017-11-21 13:11:19 -0500 | asked a question | Error with thermostatic control EnergyPlus8.8 Error with thermostatic control EnergyPlus8.8 Hi there! I'm having a bit of a problem in thermostatic control of a Heat |