2022-03-01 14:01:02 -0500 received badge  Popular Question (source)
2019-06-23 10:51:49 -0500 edited question Simple AHU EnergyPlus

Simple AHU EnergyPlus I'm quite new to Air systems in EnergyPlus and I'm trying to model a simple AHU, that should guara

2019-06-23 04:24:11 -0500 asked a question Simple AHU EnergyPlus

Simple AHU EnergyPlus I'm quite new to Air systems in EnergyPlus and I'm trying to model a simple AHU, that should guara

2019-06-19 09:07:54 -0500 edited question LoadProfile:Plant in AirLoopHVAC

LoadProfile:Plant in AirLoopHVAC Is it possible to use a LoadProfile:Plant object on the demand side of an AirLoopHVAC,

2019-06-19 09:07:13 -0500 asked a question LoadProfile:Plant in AirLoopHVAC

LoadProfile:Plant in AirLoopHVAC Is it possible to use a LoadProfile:Plant object on the demand side of an AirLoopHVAC,

2018-12-04 10:38:30 -0500 commented question How can i create a jEPlus+EA project (project.jep file) and how to update an idf file?

You need first to open jEPlus, load your idf, epw and rvx files, save the project as a .jep file, then open jEPlus+EA an

2018-11-29 09:31:47 -0500 received badge  Commentator
2018-11-29 09:31:47 -0500 commented question how to perform multi-objective optimization with jEPlus?

Did you have a look at jEPlus+EA? It's a tool where you input a jEPlus parametric model and it performs multi-objective

2018-07-11 03:11:54 -0500 commented question Parametrics EnergyPlus?

I think the question here is not about parametric or sensitivity analysis, but it is about how to parametrize input vari

2018-07-11 02:50:32 -0500 marked best answer Air Loop Heating Load is zero

I'm trying to get confidence with the AirLoopHVAC system (E+ 8.8), before applying it to complex models, so I built a simple 2 zone building, with an air loop served by a boiler and chiller, to supply conditioned air to both zones. You can find the model here.

The heating load (as well as the autosized values for the hot water loop) is always zero. Probably there is some mistake in the setpoint definition. I checked the InputOutput and example files to see what kind of error I'm doing, but I couldn't find it. If anyone could have a look at it, it would be very helpful.

2018-07-02 04:52:25 -0500 marked best answer How to include weather related objects in my parametric E+ model?

I'm building a parametric E+ simulation using jEPlus. I want to include in each idf some weather-related objects (e.g. I want to change the HVAC availability schedule, depending on which weather file is used for that simulation). Any hints for doing that? Better using EPMacro or a python code?

2018-07-02 04:44:57 -0500 asked a question Air Loop Heating Load is zero

Air Loop Heating Load is zero I'm trying to get confidence with the AirLoopHVAC system (E+ 8.8), before applying it to c

2018-07-02 04:03:51 -0500 marked best answer Adjacent heated zones in EP

The building I'm modelling in EnergyPlus is adjacent to other heated buildings. I modeled the other buildings, as adjacent thermal zones (Net part of total floor area set to No in the Zone object), conditioned by an ideal air system. When I check the results, I see the consumption of the ideal air system included in the total consumption of my building. Is there a way to exclude it from total consumption, just like I am able to exclude its area from total building area? Or, would you better recommend to model it using Other Side Coefficients as boundary conditions?

Update 01/04: I still have no solution of that problem. I need to model the adjacent zones as actual zones because I have internal windows to be taken into account. However I am still not able to exclude the energy consumption of the other zones from that of my building in the final report. Any suggestion would be highly appreciated.

2018-07-02 04:03:51 -0500 received badge  Scholar (source)
2018-07-02 04:01:54 -0500 received badge  Autobiographer
2018-02-12 04:25:55 -0500 answered a question glass door in energy plus euclid

There are 2 ways to model subsurfaces in E+: simplified and detailed. For the detailed mode you will use the Fenestratio

2018-02-09 02:48:50 -0500 received badge  Enthusiast
2018-02-07 04:43:41 -0500 answered a question Guide/tutorial to prepare a thermal building geometry by sketchup to measure the inner temperature.

I will assume you are going to use EnergyPlus or Open Studio for this model (please specify it). To build your geometry

2018-02-05 09:35:55 -0500 answered a question using python code in E+

You can't insert python code in the E+ model, it's the reverse: you use python to edit the idf file and then call the E+

2018-01-29 02:48:47 -0500 commented answer Cooling tower outlet temperature error

Thank you, I will check that out.

2018-01-27 05:40:59 -0500 edited question On/off chillers EnergyPlus

On/off chillers EnergyPlus I'm modelling a chilled water loop with EnergyPlus. I used WaterUse:Equipment to model the ch

2018-01-27 04:54:13 -0500 commented question Cooling tower outlet temperature error

I added the temperature plot. Shouldn't I expect the inlet and outlet temperature of the cooling tower to be independent

2018-01-27 04:52:09 -0500 edited question Cooling tower outlet temperature error

Cooling tower outlet temperature error I'm modelling a water cooled chiller loop in EnergyPlus. I set the cooling tower

2018-01-26 09:36:00 -0500 asked a question Cooling tower outlet temperature error

Cooling tower outlet temperature error I'm modelling a water cooled chiller loop in EnergyPlus. I set the cooling tower

2018-01-24 10:58:47 -0500 commented answer On/off chillers EnergyPlus

Thank you! Indeed I had to force mains water temperature with a schedule to close the cycle, but with LoadProfile it's m

2018-01-24 06:13:19 -0500 asked a question On/off chillers EnergyPlus

On/off chillers EnergyPlus I'm modelling a chilled water loop with EnergyPlus. I used WaterUse:Equipment to model the ch

2018-01-19 07:58:22 -0500 received badge  Supporter (source)
2018-01-05 02:45:39 -0500 commented answer Adjacent heated zones in EP

Ok so I need to subtract it. I was just hoping to find a way to do it in the input phase, without any post-processing. I

2018-01-04 10:32:00 -0500 edited question Adjacent heated zones in EP

Adjacent heated zones in EP The building I'm modelling in EnergyPlus is adjacent to other heated buildings. I modeled th

2017-12-11 04:20:52 -0500 answered a question determining heating and cooling in peak conditions

You can do both with one simulation, just adding 2 SizingPeriod:DesignDay objects, one for winter and one for summer. Th

2017-12-11 03:55:31 -0500 asked a question Adjacent heated zones in EP

Adjacent heated zones in EP The building I'm modelling in EnergyPlus is adjacent to other heated buildings. I modeled th

2017-12-01 08:46:06 -0500 received badge  Teacher (source)
2017-12-01 07:44:25 -0500 edited answer How to include weather related objects in my parametric E+ model?

Just in case someone will need it, I solved the problem in this way: I wrote a python script (as suggested by Yi Zhang),

2017-12-01 06:01:30 -0500 edited answer How to include weather related objects in my parametric E+ model?

Just in case someone will need it, I solved the problem in this way: I wrote a python script (as suggested by Yi Zhang),

2017-12-01 06:01:30 -0500 received badge  Editor (source)
2017-12-01 06:00:54 -0500 answered a question How to include weather related objects in my parametric E+ model?

Just in case someone will need it, I solved the problem in this way: I wrote a python script (as suggested by Yi Zhang),

2017-12-01 04:34:44 -0500 commented question How to include weather related objects in my parametric E+ model?

I'm going to try that. Thanks for your help!

2017-11-30 06:01:06 -0500 commented question How to include weather related objects in my parametric E+ model?

As for now they are static group of objects. I was thinking that Python should read the job name and, depending on the n

2017-11-29 10:50:52 -0500 commented question How to include weather related objects in my parametric E+ model?

Doing it maually is definitely an option (I just have 3-5 different climates, each one having a related group of objects

2017-11-28 07:36:29 -0500 asked a question How to include weather related objects in my parametric E+ model?

How to include weather related objects in my parametric E+ model? Hi all! I'm building a parametric E+ simulation using

2017-11-27 04:19:23 -0500 answered a question How to calculate the heat flux from boundaries in E+

Have you tried with Output:Variable "Surface Inside Face Conduction Heat Transfer Rate" ?

2017-11-24 11:51:12 -0500 commented question Error with thermostatic control EnergyPlus8.8

No, I'm using a VRF air to air heat pump (reference example file: DOASDXCOIL_wADPBFMethod.idf ). I get the same error in

2017-11-24 11:16:43 -0500 edited question Error with thermostatic control EnergyPlus8.8

Error with thermostatic control EnergyPlus8.8 I'm having a bit of a problem in thermostatic control of a Heat Pump (Ener

2017-11-24 08:49:56 -0500 received badge  Student (source)
2017-11-21 13:11:19 -0500 asked a question Error with thermostatic control EnergyPlus8.8

Error with thermostatic control EnergyPlus8.8 Hi there! I'm having a bit of a problem in thermostatic control of a Heat