MA_Meilleur's profile - activity

2018-07-16 11:02:45 -0600 edited question Does ideal loads consider light/equiment heat gains

Does ideal loads consider light/equiment heat gains I have an openstudio V2.5.1 large office model in cold climate (heat

2018-07-16 08:37:26 -0600 asked a question Does ideal loads consider light/equiment heat gains

Does ideal loads consider light/equiment heat gains I have an openstudio V2.5.1 large office model in cold climate (heat

2018-05-24 09:46:54 -0600 edited question Heat recovery Chiller - Central Heat Pump System

Heat recovery Chiller - Central Heat Pump System I'm trying to incorporate a heat recovery chiller between my condensing

2018-05-23 18:02:04 -0600 edited question Heat recovery Chiller - Central Heat Pump System

Heat recovery Chiller - Central Heat Pump System Hi guys, I'm trying to incorporate a heat recovery chiller between my c

2018-05-23 18:02:04 -0600 received badge  Editor (source)
2018-05-23 17:40:57 -0600 edited question Heat recovery Chiller - Central Heat Pump System

Heat recovery Chiller - Central Heat Pump System Hi guys, I'm trying to incorporate a heat recovery chiller between my c

2018-05-23 14:44:30 -0600 asked a question Heat recovery Chiller - Central Heat Pump System

Heat recovery Chiller - Central Heat Pump System Hi guys, I'm trying to incorporate a heat recovery chiller between my c

2018-05-14 15:40:59 -0600 commented answer Lights Sensible Heat Addition - Return Air Fraction

That's interesting... I would of though that a fraction of the heat gains from the lights would be lost in the plenum an

2018-05-14 12:51:29 -0600 commented answer Lights Sensible Heat Addition - Return Air Fraction

@Eric Ringold, any idea why even with the version 2.5.1, adding a return air fraction does not have an impact on 'Lights

2018-05-10 15:33:15 -0600 received badge  Teacher (source)
2018-05-10 10:02:06 -0600 answered a question Lights Sensible Heat Addition - Return Air Fraction

Quick update, I have downloaded OS V2.5.1, the 'Return Air Fraction box' is now available under 'Lights Definitions'. I

2018-05-09 12:20:44 -0600 commented answer Lights Sensible Heat Addition - Return Air Fraction

Great to know thanks ! By curiosity, what measure would you use in that context ?

2018-05-09 11:23:41 -0600 asked a question Lights Sensible Heat Addition - Return Air Fraction

Lights Sensible Heat Addition - Return Air Fraction Hi guys, I'm modeling an office building with multiple levels on OS

2017-10-15 18:39:37 -0600 received badge  Student (source)
2017-10-15 12:13:59 -0600 marked best answer Electrical equipment latent/radiant fraction heating impact

Greetings,

I'm fine tuning my residential home model, and I noticed something strange while playing with the radiant/latent fraction in the electrical equipment objects:

Adding latent and radiant heat to the object must contribute in reducing the heating load, but it seams to do the opposite, it increases the heating load and reduces the cooling load.

Am I understanding this wrong ? Thank you for your help !

2017-10-15 12:13:59 -0600 received badge  Scholar (source)
2017-10-14 19:37:44 -0600 asked a question Electrical equipment latent/radiant fraction heating impact

Electrical equipment latent/radiant fraction heating impact Greetings, I'm fine tuning my residential home model, and

2017-10-14 09:16:33 -0600 received badge  Supporter (source)