2017-04-18 09:29:03 -0500 commented answer Heating and Cooling setpoint temperatures on Design Builder

Thank you for the shotscreens

2017-04-17 22:43:06 -0500 asked a question Heating and Cooling setpoint temperatures on Design Builder

Hi!

I would like to switch on my cooling and heating systems when the operative temperature is out of the range of comfortable temperatures (i.g from 20°C to 28°C). Is it possible to set the setpoint temperatures so that the heating will be required when the zone temperature is lower than 20°C and the cooling will be required when the zone temperature is higher than 28°C ?

2017-04-14 07:36:09 -0500 received badge  Teacher (source)
2017-04-06 22:02:24 -0500 commented question Thermal properties on Construction Data, Envelop Summary(output)

I've attached some screenshots. Thank you!

2017-04-06 21:51:29 -0500 answered a question Thermal properties on Construction Data, Envelop Summary(output)

image descriptionimage description Hi! I've attached two shoot screens about my question. The components wall are cement sand render, concrete block and cement/plaster/mortar - cement screed.

2017-04-06 11:20:30 -0500 asked a question Thermal properties on Construction Data, Envelop Summary(output)

I’ve been using Design Builder to simulate my Project. On construction model data tab, I set the number of layers, the materials and the material thickness for each layer. On the calculate tab, I got 2,95 for U-value (wich is in bold). However, when I run the simulation, I got for U-value two differents values : 4,23( U-factor with film) and 11, 59 (U-factor no Film). I got confused because my maximum wall U-value allowed is 3W/m2 and the output values are much higher. Wich one should I base on?

UPDATE

I've attached two shoot screens about my question. The components wall are cement sand render, concrete block and cement/plaster/mortar - cement screed.

image description

image description

2017-03-31 13:16:20 -0500 asked a question Edit calculation options data for simulation

I simulated my model on Design Builder by setting a specific period of time (from 19 feb to 23 feb) on the simulation calculation options to generate a comfort data for typical summer conditions. I have to simulate for typical winter conditions as well, however,the Edit Calculation Options panel does not appear so that I could edit the period of time to be simulated again. The simulation runs straight providing me output data from the previous period simulated. How I could possibly sort out this problem?

2017-03-30 18:14:31 -0500 received badge  Student (source)
2017-03-30 14:13:32 -0500 asked a question Simulating for typical summer and typical winter day

I would like to know how I can simulate a building using the Design Builder for a typical summer and winter day of a specific city. I've already got the climate date from the city. However, I don't know where I should enter with the data on Design Builder. Do I get the simulation separately for each condiction( typical summer and typical winter day) ?