First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
gaofeng's profile - overview
overview
network
karma
followed questions
activity
225
karma
follow
Registered User
member since
2016-04-27 23:04:51 -0600
last seen
2018-03-19 19:57:33 -0600
todays unused votes
30
votes left
17
Questions
462
views
1
answer
3
votes
2017-01-27 14:52:38 -0600
Julien Marrec
A problem about model building in energyplus
energyplus
177
views
1
answer
2
votes
2017-01-12 08:00:14 -0600
Adam Hilton
what is the relationship between zoneinfiltration design flow rate and designspecification:outdoor air?
energyplus
infiltration
design-air-flow-rate
134
views
1
answer
2
votes
2018-03-13 04:53:24 -0600
Avi
Why both the heating and cooling load are reduced when decrease the thickness of ground slab in cold region?
energyplus
ideal-loads-air-system
199
views
1
answer
2
votes
2016-05-05 01:18:28 -0600
Waseem
How to see how much power I have saved due to the use of daylighting controls in E+?
energyplus
daylighting
281
views
1
answer
2
votes
2017-06-06 03:00:59 -0600
Julien Marrec
How to define the infiltration rate in a central zone which is composed by internal walls?
energyplus
infiltration
343
views
1
answer
1
vote
2017-07-21 09:00:13 -0600
BORM
How to reduce the impact of SHGC on energy consumption
energyplus
window
sensitivity-analysis
97
views
no
answers
1
vote
2017-11-07 09:50:41 -0600
gaofeng
Whose heating or cooling energy consumption is bigger, first floor or middle floor?
energyplus
ground-temperature
177
views
1
answer
1
vote
2018-03-11 15:01:14 -0600
Avi
The problem about the setting of ground surface temperature
energyplus
ground-temperature
179
views
no
answers
1
vote
2018-03-14 08:28:08 -0600
gaofeng
A question about the example in Energyplus 8.7——ZoneCoupledKivaSlab.idf
kiva
foundation
energyplus
157
views
1
answer
1
vote
2016-06-15 17:20:36 -0600
Adam Hilton
How to describe a opening between two zones in SU with legacy open studio
legacy-openstudio
air-wall
interior-wall
air-mixing
« previous
1
...
1
2
...
2
next »
2
Answers
1
Eplus unusual warning
0
Surface does not exist error
0
Votes
0
0
29
Tags
energyplus
× 23
infiltration
× 4
openstudio
× 2
daylighting
× 2
sketchup
× 2
trouble-shooting
× 2
zone-sizing
× 2
design-air-flow-rate
× 2
ideal-loads-air-system
× 2
ground-temperature
× 2
foundation
× 1
legacy-openstudio
× 1
error
× 1
air-mixing
× 1
warning
× 1
surface
× 1
wall
× 1
window
× 1
interior-wall
× 1
district-chilled-water
× 1
district-hot-water
× 1
air-wall
× 1
district-cooling
× 1
district-heating
× 1
energy
× 1
plus
× 1
opening
× 1
kiva
× 1
sensitivity-analysis
× 1
3
Badges
●
Student
×
1
How to see how much power I have saved due to the use of daylighting controls in E+?
●
Scholar
×
1
How to define the infiltration rate in a central zone which is composed by internal walls?
●
Teacher
×
1
Eplus unusual warning
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how