First time here? Check out the Help page!
2018-03-14 08:28:08 -0500 | asked a question | A question about the example in Energyplus 8.7——ZoneCoupledKivaSlab.idf A question about the example in Energyplus 8.7——ZoneCoupledKivaSlab.idf ZoneCoupledKivaSlab.idf is a example Energyplus8 |
2018-03-13 10:58:40 -0500 | commented answer | Why both the heating and cooling load are reduced when decrease the thickness of ground slab in cold region? Thanks for your suggestion, I have used the foundation Kiva and the result is improved, I will go on adjusting. Many tha |
2018-03-13 03:07:59 -0500 | asked a question | Why both the heating and cooling load are reduced when decrease the thickness of ground slab in cold region? Why both the heating and cooling load are reduced when decrease the thickness of ground slad in cold region? When I used |
2018-03-12 09:18:31 -0500 | marked best answer | The problem about the setting of ground surface temperature When I define the ground surface temperature based on the handbook that 2C less than the indoor temperature, the thickness showed a positive correlation with Heating energy comsumption, and heat conductivity coefficient showed a negative correlation with heating energy in a severe cold region. It seems that the ground has a heating effect. That is abnormal, so dose anyone has encontered the some problem or how to change it. |
2018-03-07 09:15:10 -0500 | asked a question | The problem about the setting of ground surface temperature The problem about the setting of ground surface temperature When I define the ground surface temperature based on the h |
2017-11-07 09:50:41 -0500 | asked a question | Whose heating or cooling energy consumption is bigger, first floor or middle floor? Whose heating or cooling energy consumption is bigger, first floor or middle floor? Hey guys, I have a question about th |
2017-07-21 03:13:10 -0500 | asked a question | How to reduce the impact of SHGC on energy consumption How to reduce the impact of SHGC on energy consumption Recently, I made a sensitivity analysis on building energy heatin |
2017-06-07 04:18:55 -0500 | marked best answer | How to define the infiltration rate in a central zone which is composed by internal walls? The defination of infiltration is the outside air from the crack of building. So, how to set the infiltration rate in a central zone which is composed by internal walls. Theoretically, there is no direct outdoor air to go into this area, but the mixture of indoor and outdoor air. How about setting a smaller value than common situation? or set zero in this situation? |
2017-06-07 04:18:55 -0500 | received badge | ● Scholar (source) |
2017-06-01 08:48:34 -0500 | asked a question | Does anyone have seen the fatal error of Number of ObjectDef Numeric Args> Size of NumericArg array when apply the function of Geometry transform? Does anyone have seen the fatal error of Number of ObjectDef Numeric Args> Size of NumericArg array when apply the fu |
2017-05-31 07:51:46 -0500 | commented answer | How to define the infiltration rate in a central zone which is composed by internal walls? Thanks for your answer, but for a non-perimeter zone, how to define its infiltration (flow/zone) value. Have you ever se |
2017-05-29 09:55:12 -0500 | asked a question | How to define the infiltration rate in a central zone which is composed by internal walls? How to define the infiltration rate in a central zone which is composed by internal walls? The defination of infiltratio |
2017-05-29 09:52:04 -0500 | asked a question | How to define the infiltration flowrate in a central zone which is composed by internal wall? How to define the infiltration flowrate in a central zone which is composed by internal wall? The defination of infiltra |
2017-01-12 08:17:30 -0500 | commented answer | what is the relationship between zoneinfiltration design flow rate and designspecification:outdoor air? Thank you for the reply, but forgive that I'm not the HVAC major. I used ideal loads air system in my project, and I have to set the design specification : outdoor air. whether you mean that this OA is arise the mechanical ventilation and will result in the change of space cooling and heating. |
2017-01-12 06:59:09 -0500 | asked a question | what is the relationship between zoneinfiltration design flow rate and designspecification:outdoor air? For infiltration, it is the outdoor air from the crack of building envelop. But the define of design specification outdoor air is confused? Do they have any relationship? Many thanks |
2017-01-04 17:02:21 -0500 | asked a question | How to understand district cooling and heating and Zone Total cooling and Heating Energy Sorry to ask a primary question. I simulate the building model using Ideal loads air system with outdoor air. In the beginning, I considered the districting cooling and heating energy as the cooling and heating energy requirements. However, when I sum all zones cooling and heating energy (Output:Variable:Zone Ideal Loads Zone Total Cooling Energy),the result has a big difference from district cooling and heating as follow. I can understand the zone total cooling energy is bigger than district cooling because the outdoot air.But in the winter, the outdoor air should also enlarges the zone total heating energy which ought to bigger than district heating. However the result is opposite. In additional, If the district cooling and heating is the heating and cooling energy requirements, then how to statistics each zone' s heating and cooling energy requirements. |
2016-12-29 07:33:22 -0500 | commented answer | How to solve the warnings as follow? Thank you for your helps, rely on your suggestions, I have solved my problems |
2016-12-25 09:37:45 -0500 | asked a question | How to solve the warnings as follow? The error report show that,
Any suggestion is appreciative |
2016-12-22 06:16:43 -0500 | asked a question | How to solve the big difference bwtween district cooling and heating? I use the ideal air loads system to siumlate the building load, the result shows a big difference between district cooling and heating as follow: There no big apparent unreasonable sets in the model, So whether this difference arises from the ideal air loads system? |
2016-12-19 08:26:10 -0500 | asked a question | A fatal error in energyplus I used openstudio to build the building model and simulate in energyplus, but this project has some errors as follow: * Severe * IP: IDF line~13 Multiple occurrences of Unique Object=Version * Severe * IP: Other miscellaneous errors found in input * Severe * IP: Out of "range" values and/or blank required fields found in input * Fatal * IP: Errors occurred on processing IDF file. Preceding condition(s) cause termination. I'm a new user, so if anyone could give me some advices, many thanks. |
2016-12-15 03:25:52 -0500 | commented answer | A problem about model building in energyplus Thank you for your help, I will change it and check the result. But I always have another question for thermal zone. That is whether I can set two zones which locate in different storeys into a same thermal, or I can just set the zone in same storey to the same thermal zones. |
2016-12-14 11:00:26 -0500 | asked a question | A problem about model building in energyplus When I run the simulation in E+, there is always a warning as follows: I want to know how I can fix this problem? |
2016-05-09 08:17:01 -0500 | asked a question | How to define a virtual interface which has the funcation of air exchange and transparency between two zone in E+? In fact ,there is a opening between two zones in my model, and I hope this opening has the funcation of air exchange and transparency. So, I draw a open area in SU between two zones, but the result is unsatisfactory. So I want to know how to modify this model to make the result more reasonable. |
2016-05-07 15:07:32 -0500 | received badge | ● Teacher (source) |
2016-05-07 06:59:45 -0500 | answered a question | Surface does not exist error I had met this situation before, you need redraw the you model, maybe there are some problems from your drawing method which conflicts with OS' s drawing language. |
2016-05-07 06:44:45 -0500 | commented answer | What do you need to know about surfaces in contact with the ground, when modeling in Open Studio? It doesn‘t matter in OS, I think, because you can change the details in E+ |
2016-05-07 06:30:14 -0500 | answered a question | Eplus unusual warning In my view, you can try to reset the maximum surface convection heat transfer coefficient value to the default value 1000. I'm not sure whether this method can solve your problem, just a suggestion. |
2016-05-07 06:21:53 -0500 | commented answer | How to see how much power I have saved due to the use of daylighting controls in E+? Thanks for your help. I will try your suggestion as soon as possible. |
2016-05-05 11:44:48 -0500 | received badge | ● Student (source) |
2016-05-05 00:11:16 -0500 | asked a question | How to see how much power I have saved due to the use of daylighting controls in E+? Recently, I make an example to analyze the atrium energy performance. One of my tasks is to study the effect of daylighting on lighting energy performance, and I set the parameter according to the examples in E+. But I can't find the maeningful result from the output.Maybe there are some errors in my setup, but I'm not sure about it. So, I ask this question here.(Ps. the targrt zone is ad5 |
2016-04-28 08:39:13 -0500 | asked a question | How to describe a opening between two zones in SU with legacy open studio Sometimes, there is no internal wall between two zones, but just a opening. So, how to describe this are in SU with legacy open studio. Though I can draw this situation in SU software, I'm not sure whether this method accord with the principle of software |