2020-02-02 16:54:19 -0500 answered a question How to aggregate PV panels to different zones - DesignBuilder or E+

Hi, DesignBuilder doesn't allow you to allocate/connect electricity generated from PV system to any thermal zone. What i

2019-12-04 05:04:46 -0500 received badge  Teacher (source)
2019-12-04 04:54:33 -0500 commented answer Advice on modelling irregular bulkhead in DesignBuilder

Hi Jadin, Thanks for the images, that clarify a lot of things. DesignBuilder detects those ceilings as walls since they

2019-12-02 03:19:38 -0500 answered a question Advice on modelling irregular bulkhead in DesignBuilder

Hi Jadin, If DesignBuidler detects a surface as internal then it means both sides of that wall are adjoining zones. It c

2019-12-02 03:19:19 -0500 answered a question Severe error (Error parsing "Schedule:Day:Interval") when running the idf file.

Try including the word 'until' in the time. For example: until: 00:15,

2019-11-08 12:06:57 -0500 commented answer DX:SingleSpeed Heating Coil - Heating Capacity

Hi Aaron, Thanks.

2019-11-07 15:58:57 -0500 marked best answer DX:SingleSpeed Heating Coil - Heating Capacity

Hi, I have a building model with Packaged Terminal Heat Pump. I want to use EMS to change the DX cooling / heating coil capacity. In the .edd file I found the Actuator for the cooling coil total cooling capacity:

"EnergyManagementSystem:Actuator Available,1LEVEL1:T3WEST PTHP DX COOLING COIL,Coil:Cooling:DX:SingleSpeed,Autosized Rated Total Cooling Capacity,[W]"

But I can't find the equivalent Actuator for the heating coil. Does anyone know what is the equivalent for heating coil? Or how to change the heating capacity?

Thanks.

2019-11-07 15:58:57 -0500 received badge  Scholar (source)
2019-11-07 08:50:28 -0500 asked a question DX:SingleSpeed Heating Coil - Heating Capacity

DX:SingleSpeed Heating Coil - Heating Capacity Hi, I have a building model with Packaged Terminal Heat Pump. I want to u