2023-12-12 11:44:30 -0500 | commented question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" Yes, I removed HVAC systems prior to (using a measure). I have tried positing a link to my dropbox. |
2023-12-12 11:41:07 -0500 | edited question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" I'm running OpenStudio on one of the |
2023-12-12 09:25:10 -0500 | commented question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" Sorry not too familiar, used the wrong version, the SDK version I'm on is 3.6.1 - also forgot to note that I added the E |
2023-12-12 09:24:40 -0500 | commented question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" Sorry not too familiar, used the wrong version, the SDK version I'm on is 3.6.1 - also forgot to note that I added the E |
2023-12-12 09:23:34 -0500 | edited question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" I'm running OpenStudio on one of the |
2023-12-12 09:18:19 -0500 | edited question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" I'm running OpenStudio on one of the |
2023-12-12 09:17:26 -0500 | edited question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" I'm running OpenStudio on one of the |
2023-12-11 15:17:56 -0500 | commented question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" added the images, as you can see, the District totals are far greater than the Heating and Cooling Requirements. |
2023-12-11 15:16:55 -0500 | edited question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" I'm running OpenStudio on one of the |
2023-12-11 15:13:22 -0500 | edited question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" I'm running OpenStudio on one of the |
2023-11-27 09:38:16 -0500 | received badge | ● Student (source) |
2023-11-27 09:23:59 -0500 | asked a question | OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" OpenStudio Results Report - "Energy Use" values significantly higher than "End Use" I'm running OpenStudio on one of the |
2023-10-17 15:23:22 -0500 | commented question | Window U-factor improvements - increase window heat gain? Thanks!, that makes sense to me, I was focused on the energy transmitted, but ignored the absorbed radiation that would |
2023-10-13 17:12:55 -0500 | commented question | Window U-factor improvements - increase window heat gain? For U-value from 4.24 to 2.04 - Increases in cooling seen throughout the entire year besides July, from 4.24 to 1.70 - |
2023-10-13 17:12:49 -0500 | commented question | Window U-factor improvements - increase window heat gain? I ran another simulation, and compared to the similar question. Holding SHGC constant , improving U-value I get the fo |
2023-10-13 09:03:26 -0500 | commented question | Window U-factor improvements - increase window heat gain? Using Energy Plus through Open Studio, exporting report "envelope_and_internal_load_breakdown_report" |
2023-10-13 09:03:20 -0500 | edited question | Window U-factor improvements - increase window heat gain? Window U-factor improvements - increase window heat gain? Curious, For a large office prototype model, 20 stories, 38% |
2023-10-12 09:04:26 -0500 | asked a question | U-value improvements, increases cooling load? U-value improvements, increases cooling load? Curious, For a large office prototype model, 20 stories, 38% fenestration |
2023-10-12 09:04:22 -0500 | asked a question | Window U-factor improvements - increase window heat gain? Window U-factor improvements - increase window heat gain? Curious, For a large office prototype model, 20 stories, 38% |