2022-09-14 07:42:26 -0500 commented answer CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

Thank you very much for this detailed feedback. I'll try to fix all these mistakes. I won't hesitate to come back to you

2022-09-13 09:54:41 -0500 commented question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

There isn't a window in the building. I only putted doors that I defined with the section called "Doors".

2022-09-13 09:50:31 -0500 commented question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

Here you have the link to the Google Drive : https://drive.google.com/drive/folders/1q-qv9XsnrxL5f5_X54VhTpcj-z1JfRzY?us

2022-09-13 07:14:28 -0500 commented question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

Thank you for your answer Jason. I defined the floor and the ceiling for the zone called "ROOM"

2022-09-13 07:14:03 -0500 commented question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

I defined the floor and the ceiling for the zone called "ROOM"

2022-09-13 07:13:48 -0500 commented question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

I defined the flloor and the ceiling for the zone called "ROOM"

2022-09-13 07:12:54 -0500 commented question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

Thank you for your answer Denis . It is actually the case. How can I share you my IDF file ? I can't link a IDF from her

2022-09-13 07:12:20 -0500 commented question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

Thank you for your answer @denisbourgeois. It is actually the case. How can I share you my IDF file ? I can't link a IDF

2022-09-13 07:01:27 -0500 edited question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an

2022-09-13 07:01:27 -0500 received badge  Editor (source)
2022-09-12 03:13:16 -0500 asked a question CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an edge on one other surface.

CalculateZoneVolume: The Zone="ROOM" is not fully enclosed. To be fully enclosed, each edge of a surface must also be an

2022-09-07 09:32:33 -0500 received badge  Student (source)
2022-09-07 09:27:13 -0500 commented answer Thermal Comfort Reporting

Thank you very much for your answer ! I added a schedule named "Activity Level" that I forgot to add in the section "Sch

2022-09-06 09:46:09 -0500 marked best answer Thermal Comfort Reporting

Hello everyone ! I just started using EnergyPlus one month ago and I'm struggling a bit. I'm trying to run a simulation but I have this warning :

 ** Warning ** GetInternalHeatGains: People="ROOM PEOPLE", Activity Level Schedule Name values
**   ~~~   ** fall outside typical range [70,1000] W/person for Thermal Comfort Reporting.
**   ~~~   ** Odd comfort values may result; Schedule="OFFICE OCCUPANCY 2".
**   ~~~   ** Entered min/max range=[0.0,] W/person.1.0

I used the same schedules from the exemple AdultCenter2 given in the examples files.

Is there someone that has already had this kind of warning ? I tried to change the number of people and change the schedule but I can't solve the problem.

Thank you in advance for your help ! Samuel

2022-09-06 09:46:09 -0500 received badge  Scholar (source)
2022-09-06 08:58:06 -0500 asked a question Thermal Comfort Reporting

Thermal Comfort Reporting Hello everyone ! I just started using EnergyPlus one month ago and I'm struggling a bit. I'm t