First time here? Check out the Help page!
2020-12-14 12:52:19 -0500 | received badge | ● Famous Question (source) |
2020-03-24 23:17:23 -0500 | asked a question | OpenStudio: Export Schedules as CSV? OpenStudio: Export Schedules as CSV? Hi, Is there a way to export/look at the various schedules that are in a model in |
2020-01-03 21:37:25 -0500 | received badge | ● Notable Question (source) |
2020-01-03 21:37:25 -0500 | received badge | ● Popular Question (source) |
2019-10-29 15:58:53 -0500 | commented question | Beopt Report Output Error By the way, this was in the multifamily mode. Haven't had this issue in single family mode. |
2019-10-25 19:03:37 -0500 | asked a question | Beopt Report Output Error Beopt Report Output Error Hi, I've never had this issue before and it seems to have come up just now - error while runn |
2018-10-29 12:54:51 -0500 | commented answer | Lighting Profile/Schedule in BEopt Thank you so much for your assistance and your help, Eric! |
2018-10-28 21:37:13 -0500 | asked a question | Lighting Profile/Schedule in BEopt Lighting Profile/Schedule in BEopt Hello, I was wondering why the BEopt lighting schedule seems to be different from th |
2018-10-12 14:22:44 -0500 | commented answer | Setting Electric Heat Lockout Temperature in BEopt Thank you for your reply, Eric! Trying to model heat pumps in cold climates is challenging, and locking out the strip he |
2018-10-12 14:15:25 -0500 | asked a question | Dual Fuel Heat Pump in BEopt? Dual Fuel Heat Pump in BEopt? It seems that the only way to model an air-source heat pump is with electric supplemental |
2018-10-12 14:03:58 -0500 | asked a question | Setting Electric Heat Lockout Temperature in BEopt Setting Electric Heat Lockout Temperature in BEopt Hello, I was wondering regarding the correct way to set the lockout |
2018-10-01 10:09:15 -0500 | received badge | ● Student (source) |
2018-10-01 09:12:03 -0500 | asked a question | How to see autosized capacity BEopt? How to see autosized capacity BEopt? Was wondering how to see the autosized equipment capacity in BEopt. It was previous |
2018-10-01 09:11:58 -0500 | asked a question | Calculated values in beopt Calculated values in beopt Hello, Was wondering if you could clarify why the calculated R-assembly values are not showi |
2018-10-01 09:11:49 -0500 | asked a question | BEopt: What is the autosized heating capacity for heat pump? BEopt: What is the autosized heating capacity for heat pump? When modeling an ASHP, it seems the only place that I can f |