2021-11-16 10:25:59 -0500 commented question Adding real-time weather data to running simulation and continuing computation instead of restarting the simulation

@Aaron Boranian I actually have encountered those before asking my question. But it looks like those do not have an inpu

2021-11-16 10:25:35 -0500 commented question Adding real-time weather data to running simulation and continuing computation instead of restarting the simulation

@Aaron I actually have encountered those before asking my question. But it looks like those do not have an input for wea

2021-11-15 08:07:06 -0500 asked a question Adding real-time weather data to running simulation and continuing computation instead of restarting the simulation

Adding real-time weather data to running simulation and continuing computation instead of restarting the simulation Let'

2019-09-10 03:09:47 -0500 edited question EnergyPlus Error Temperature & Relative Humidity Out of Bounds when using Window Blinds

EnergyPlus Error Temperature & Relative Humidity Out of Bounds when using Window Blinds I have a perfectly working s

2019-09-10 02:59:33 -0500 edited question EnergyPlus Error Temperature & Relative Humidity Out of Bounds when using Window Blinds

EnergyPlus Error Temperature & Relative Humidity Out of Bounds when using Window Blinds I have a perfectly working s

2019-09-10 02:58:11 -0500 edited question EnergyPlus Error Temperature & Relative Humidity Out of Bounds when using Window Blinds

EnergyPlus Error Temperature & Relative Humidity Out of Bounds when using Window Blinds I have a perfectly working s

2019-09-10 02:55:30 -0500 asked a question EnergyPlus Error Temperature & Relative Humidity Out of Bounds when using Window Blinds

EnergyPlus Error Temperature & Relative Humidity Out of Bounds when using Window Blinds I have a perfectly working s

2019-08-19 20:27:13 -0500 commented answer Warmup convergence

So for the "history in the thermal mass", the final conditions of the thermal mass in the warm up will be used for the a

2019-08-10 06:14:31 -0500 commented answer Warmup convergence

Can you give me an intuition on this matter? I have read this one and I can't seem to follow. I want to understand how

2019-08-10 06:14:06 -0500 commented answer Warmup convergence

Can you give me an intuition on this matter? I have read this one and I can't seem to follow. I want to understand how

2019-06-26 01:37:44 -0500 asked a question Warmup convergence

Warmup convergence I tried to read the EnergyPlus documentation on page 12. I can't seem to understand what is the purpo

2018-12-26 11:21:15 -0500 asked a question Absorbed radiation

Absorbed radiation What does this mean? in the calculation of "Absorbed Radiation". This is found in the engineering r

2018-11-06 19:03:51 -0500 received badge  Supporter (source)
2018-11-06 05:54:41 -0500 asked a question How does a light shelf model work in EnergyPlus?

How does a light shelf model work in EnergyPlus? Does light shelf work like a shading object limiting solar energy to hi

2018-03-13 07:04:14 -0500 edited question How should I model occupancy in school?

How should I model occupancy in school? I am planning to model occupancy in rooms of our school and would like to know h

2018-03-13 07:04:14 -0500 received badge  Editor (source)
2018-03-13 06:49:29 -0500 edited question How should I model occupancy in school?

How should I model occupancy in school? I am planning to model occupancy in rooms of our school and would like to know h

2018-03-13 06:48:35 -0500 asked a question How should I model occupancy in school?

How should I model occupancy in school? I am planning to model occupancy in rooms of our school and would like to know h

2018-03-13 04:43:42 -0500 commented answer What is the minimum time step of the weather data file to have the minimum error?

Right now, we still creating baseline model for our school building here. The model is hopefully for retrofits. We wante

2018-03-13 01:52:28 -0500 commented answer What is the minimum time step of the weather data file to have the minimum error?

Yes. I have check auxiliary programs, if 1 hour resolution is not valid then we will opt using the weather converter fro

2018-03-12 23:11:23 -0500 asked a question What is the minimum time step of the weather data file to have the minimum error?

What is the minimum time step of the weather data file to have the minimum error? I saw an available weather data file t

2018-02-26 09:42:34 -0500 commented answer What causes OpenStudio Model in SketchUp to only show wireframes?

However, I saw a link from the links you have posted and it says to open the ruby console before opening the openstudio

2018-02-26 07:03:42 -0500 received badge  Student (source)
2018-02-26 00:36:32 -0500 commented answer What causes OpenStudio Model in SketchUp to only show wireframes?

I have checked the links. Now, it is still in wireframe. I didn't use WWR and surface matching (which I eventually wil

2018-02-25 16:47:34 -0500 asked a question What causes OpenStudio Model in SketchUp to only show wireframes?

What causes OpenStudio Model in SketchUp to only show wireframes? My OpenStudio model in SketchUp was properly saved and