First time here? Check out the Help page!
2020-10-01 05:12:58 -0500 | marked best answer | Difference between Ideal Loads Supply Air Total Cooling Rate and District Cooling at peak Version: EnergyPlus 8.7 Buidling: a little shop with one conditioned thermal zone (ZONE1) and one unconditioned attic. HVAC Template : Ideal Load Air System. When I sum, hour per hour during over the year, the output "ZONE1:Zone Ideal Loads Supply Air Total Cooling Rate[W]" , I get the same value as the one of "District Cooling [kWh]" of the Annual Building Utility Performance Summary, which seems consistent. But the maximum value, over the year, of the output "ZONE1:Zone Ideal Loads Supply Air Total Cooling Rate[W]" does not correspond to the "District Cooling [W]" at peak in the Demand End Use Components Summary, which does not seem consistent. What is the right value to be considered in order to determine the cooling loads of the HVAC system ? - maximum of "ZONE1:Zone Ideal Loads Supply Air Total Cooling Rate[W]" OR - "District Cooling [W]" at peak. |
2019-11-15 08:57:39 -0500 | received badge | ● Notable Question (source) |
2019-11-15 08:57:39 -0500 | received badge | ● Popular Question (source) |
2018-07-17 15:15:51 -0500 | asked a question | Difference between Ideal Loads Supply Air Total Cooling Rate and District Cooling at peak Difference between Ideal Loads Supply Air Total Cooling Rate and District Cooling at peak Version: EnergyPlus 8.7 Buidl |
2018-01-21 08:40:19 -0500 | commented question | ERROR using Euclid for Sketchup when loading climate file Yes of course: http://www.labeee.ufsc.br/sites/default/files/arquivos_climaticos/2015/BRA_SP_Sao.Paulo.837810_INMET.zip |
2018-01-19 12:46:00 -0500 | asked a question | ERROR using Euclid for Sketchup when loading climate file ERROR using Euclide for Sketchup when loading climate file Hello, I am using the following the pluggin Euclide for Sket |
2017-11-24 08:50:52 -0500 | received badge | ● Student (source) |
2017-11-22 05:54:07 -0500 | commented question | Energy balance - Thermal zone without HVAC I donĀ“t think so, beacause the space is not conditioned and the help precises "When specified, the Zone Component Loads |
2017-11-21 14:31:30 -0500 | received badge | ● Organizer (source) |
2017-11-21 14:30:58 -0500 | edited question | Energy balance - Thermal zone without HVAC Energy balance - Thermal zone without HVAC I would like to get the energy balance of a thermal zone without HVAC (only w |
2017-11-21 14:30:42 -0500 | edited question | Energy balance - Thermal zone without HVAC Energy balance - Thermal zone without HVAC I would like to get the energy balance of a thermal zone without HVAC (only w |
2017-11-21 14:30:42 -0500 | received badge | ● Editor (source) |
2017-11-21 14:29:49 -0500 | edited question | Energy balance - Thermal zone without HVAC Energy balance - Thermal zone without HVAC I would like to get the energy balance of a thermal zone without HVAC (only w |
2017-11-21 13:32:06 -0500 | asked a question | Energy Balance - thermal zone without HVAC Energy Balance - thermal zone without HVAC I would like to get the energy balance of a thermal zone without HVAC (only w |
2017-11-21 13:32:06 -0500 | asked a question | Energy balance - Thermal zone without HVAC Energy balance - Thermal zone without HVAC I would like to get the energy balance of a thermal zone without HVAC (only w |