Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

kwon1579's profile - activity

2023-05-12 13:16:52 -0500 marked best answer How do I turn on/off PTAC at right temperature?

C:\fakepath(4).png
https://tinyurl.com/energyplusQ
Please refer to the photo and file above (part of my EnergyPlus)

How do I make my PTAC/Thermostat so that it turns on when thermostat temperature is out of range and turns off during the range of given deadband? I feel like I am doing something wrong on "Scheduling" but not sure how to include "Temperature" in that ScheduleCompact. If this is possible, would you mind showing me the example?

2023-05-12 13:16:52 -0500 received badge  Scholar (source)
2023-05-05 17:43:23 -0500 commented answer How do I turn on/off PTAC at right temperature?

thank soooooo much and sorry but how do I fix this....? * Severe * GetZoneAirSetpoints: Could not find ThermostatSet

2023-05-05 16:14:24 -0500 commented answer How do I turn on/off PTAC at right temperature?

Sorry this also (Severe error) * Severe * ZoneHVAC:PackagedTerminalAirConditioner "PTAC DX CLG ELEC HTG" * ~~

2023-05-05 16:12:21 -0500 commented answer How do I turn on/off PTAC at right temperature?

that gives me this error :/ * Fatal * GetPTUnit: Errors found in getting input. ...Summary of Errors that led t

2023-05-05 15:36:21 -0500 asked a question What is the output variable for Electricity Usage in kWh or kW?

What is the output variable for Electricity Usage in kWh or kW? Hi, I am currently using ZoneHVAC:PackagedTerminalAirCo

2023-05-05 14:42:43 -0500 commented answer How do I turn on/off PTAC at right temperature?

No I have ZoneControl:Thermostat if you visit the tinyurl it will show you PNG is just part of it

2023-05-04 17:15:46 -0500 asked a question How do I turn on/off PTAC at right temperature?

How do I turn on/off PTAC at right temperature? C:\fakepath(4).png https://tinyurl.com/energyplusQ Please refer to the

2023-05-04 13:05:07 -0500 edited question [EnergyPlus] ZoneHVAC:PTAC never turns off (in deadband)

[EnergyPlus] ZoneHVAC:PTAC never turns off (in deadband) Right now, I am using ZoneHVAC:PTAC with ThermostatSetpoint:Dua

2023-05-04 13:05:07 -0500 received badge  Editor (source)
2023-05-04 13:04:10 -0500 asked a question [EnergyPlus] ZoneHVAC:PTAC never turns off (in deadband)

[EnergyPlus] ZoneHVAC:PTAC never turns off (in deadband) Right now, I am using ZoneHVAC:PTAC with ThermostatSetpoint:Dua

2023-05-04 12:54:22 -0500 commented answer [EnergyPlus] ThermostatSetpoint:DualHeatingCooling

when I changed Schedule:Constant,Always On Discrete hvac_library,OnOff hvac_library,1; this to zero to turn off, it gave

2023-05-04 12:51:41 -0500 received badge  Supporter (source)
2023-05-04 12:51:34 -0500 commented answer [EnergyPlus] ThermostatSetpoint:DualHeatingCooling

is there no way to tell them "run when above 20C"?

2023-05-04 12:48:27 -0500 commented answer [EnergyPlus] ThermostatSetpoint:DualHeatingCooling

The Always On Discrete hvac_library is name of the Schedule: Schedule:Constant,Always On Discrete hvac_library,OnOff hv

2023-05-04 12:44:51 -0500 commented answer [EnergyPlus] ThermostatSetpoint:DualHeatingCooling

the output values of "PTAC DX CLG ELEC HTG:Zone Packaged Terminal Air Conditioner Total Cooling Energy J" and "PTAC DX C

2023-05-04 12:35:39 -0500 asked a question [EnergyPlus] ThermostatSetpoint:DualHeatingCooling

[EnergyPlus] ThermostatSetpoint:DualHeatingCooling Right now, I am using ZoneHVAC:PTAC with ThermostatSetpoint:DualHeati

2021-07-31 12:55:57 -0500 received badge  Student (source)
2021-07-27 07:45:42 -0500 asked a question Is there any way to manually edit the Zone Air Temperature?

Is there any way to manually edit the Zone Air Temperature? Right now I am using Energy Plus. I am just conducting a sim