ADD's profile - activity

2017-11-29 19:19:59 -0500 commented answer Why does DCV increase CO2 levels?

I didn't know that , thank you so much

2017-11-28 11:02:07 -0500 commented answer Why does DCV increase CO2 levels?

Yes, I had the same problem no matter what I defined for setpoint schedule. I will try to apply your suggestion, too. Th

2017-11-28 11:01:59 -0500 commented answer Why does DCV increase CO2 levels?

Yes, I had the same problem no matter what I defined for setpoint schedule. I will try to apply your suggestion, too. Th

2017-11-28 10:58:45 -0500 edited question Why does DCV increase CO2 levels?

Why does DCV increase CO2 levels? I have a secondary school which needs to be ventilated based on CO2 levels in EnergyPl

2017-11-26 18:04:54 -0500 edited question Why does DCV increase CO2 levels?

Why does DCV increase CO2 levels? I have a secondary school which needs to be ventilated based on CO2 levels. I have tri

2017-11-26 18:04:30 -0500 edited question Why does DCV increase CO2 levels?

Why does DCV increase CO2 levels? I have a secondary school which needs to be ventilated based on CO2 levels. I have tri

2017-11-26 18:03:25 -0500 commented question Why does DCV increase CO2 levels?

Thanks for your answer. I replied your question as an answer.

2017-11-26 18:01:57 -0500 answered a question Why does DCV increase CO2 levels?

CO2 setpoint is 400ppm as dimentionless schedule, Co2 outdoor emission is 400 ppm which I defined as minimum emissio

2017-11-26 17:46:07 -0500 edited question Why does DCV increase CO2 levels?

Why does DCV increase CO2 levels? I have a secondary school which needs to be ventilated based on CO2 levels. I have tri

2017-11-26 17:45:59 -0500 edited question Why does DCV increase CO2 levels?

Why does DCV increase CO2 levels? I have a secondary school which needs to be ventilated based on CO2 levels. I have tri

2017-11-25 20:58:05 -0500 edited question Why does DCV increase CO2 levels?

Why does DCV increase CO2 levels? I have a secondary school which needs to be ventilated based on CO2 levels. I have tri

2017-11-25 20:57:19 -0500 asked a question Why does DCV increase CO2 levels?

Why does DCV increase CO2 levels? I have a secondary classroom which needs to be ventilated based on CO2 levels. I have

2017-09-18 15:44:00 -0500 commented answer Implementation of electrochromic window in OpenStudio

I have gone through that EMS example for Thermochromic glazing to understand the idea behind EMS. I will try your steps.

2017-09-14 12:00:15 -0500 commented question Implementation of electrochromic window in OpenStudio

I want to model 4 steps depending upon SHGC.

2017-09-08 11:21:07 -0500 edited question Implementation of electrochromic window in OpenStudio

Implementation of electrochromic window in OpenStudio I have searched unmet hours to find a way for modeling of dynamic

2017-09-08 11:21:05 -0500 edited question Implementation of electrochromic window in OpenStudio

Implementation of thermochromic window in OpenStudio I have searched unmet hours to find a way for modeling of dynamic g

2017-08-24 16:55:05 -0500 asked a question Implementation of electrochromic window in OpenStudio

Implementation of thermochromic window in OpenStudio Hi everyone, I have searched unmet hours to find a way for modeling

2017-08-07 12:50:02 -0500 commented question Humidity Capacity Multiplier @Open Studio Software

Thanks for response. I appreciate

2017-08-07 12:49:44 -0500 commented question Humidity Capacity Multiplier @Open Studio Software

it is Open Studio software

2017-08-07 12:49:14 -0500 commented answer IDF file to OSM -error with HVAC reversion

Thanks. Actually I am trying to not stay in energyplus. So as to do that, I need to find way to import everything from

2017-08-07 12:46:44 -0500 commented answer IDF file to OSM -error with HVAC reversion

Actually I am trying to not stay in energyplus. So as to do that, I need to find way to import everything from energyPlu

2017-08-04 12:33:22 -0500 asked a question IDF file to OSM -error with HVAC reversion

IDF file to OSM -error with HVAC reversion I am working on PNNL prototype buildings which include all idf files created

2017-04-01 12:25:31 -0500 received badge  Supporter (source)
2017-03-29 12:59:35 -0500 received badge  Student (source)
2017-03-29 11:51:44 -0500 commented question Humidity Capacity Multiplier @Open Studio Software

it is Open Studio software

2017-03-29 11:51:20 -0500 received badge  Editor (source)
2017-03-29 09:31:00 -0500 asked a question Humidity Capacity Multiplier @Open Studio Software

Humidity capacity is a function of construction materials and indoor furniture. I mean what you have in your zone like wood construction for walls or ceramic tile which have different moisture absorbance capacity is really important to deal with this value. But there is only one section to change that value for all structure we have. How is application of different Humidity capacity multipliers for each zones possible if I want to use for each zones which have different materials?