First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
designbuilderknowledge's profile - overview
overview
network
karma
followed questions
activity
243
karma
follow
Registered User
member since
2016-10-06 08:03:29 -0600
last seen
2017-10-28 13:35:54 -0600
todays unused votes
30
votes left
14
Questions
156
views
1
answer
3
votes
2017-03-13 07:51:25 -0600
banicu
I would like to use an Inorganic PCM that we will encapsulate using a polymer for water cooling. Any suggestion for a good PCM and a software for simulating results.
phase-change-material
165
views
1
answer
3
votes
2016-11-28 05:38:55 -0600
designbuilderknowledge
I have an EMS file that runs with No erros but doesn't control the output
designbuilder
ems
691
views
2
answers
3
votes
2016-10-12 18:00:36 -0600
Ivan Korolija
I want a site with constant temperature and 0 solar radiation how to edit weather files
designbuilder
weather-file
105
views
1
answer
2
votes
2016-12-15 02:13:20 -0600
Dave
Transmission losses very low using design builder
designbuilder
heating-load
815
views
2
answers
2
votes
2016-10-20 08:48:08 -0600
Ivan Korolija
How to set a deadband so while the zone air temperature is between 22 and 26°C the heating system is off.Am using designbuilder so maybe I can do this through an EMS file
designbuilder
setpoint
ems
energyplus
103
views
1
answer
1
vote
2016-11-08 15:56:16 -0600
ericringold
How to model core activation for a single zone using design builder
designbuilder
radiant-heating
166
views
1
answer
1
vote
2016-10-18 04:21:47 -0600
designbuilderknowledge
I have set the heating setpoint to 26°C yet when I simulate it stops at 20°C in designbuilder
designbuilder
zone-temperature
setpoint
139
views
no
answers
1
vote
2017-10-22 04:17:42 -0600
designbuilderknowledge
I am using anys to create a heat exchanger containing parallel slabs. the heat exchanger is defined as a solid body i need it to be hollow to allow air flow. any ideas?
ansys
geometry
heat-exchanger
353
views
1
answer
1
vote
2016-12-15 02:33:38 -0600
Dave
heat gains through glazing more than losses in design builder
designbuilder
glazing
295
views
1
answer
1
vote
2016-10-06 08:04:35 -0600
designbuilderknowledge
how to create a single zone with 3 interior walls and a single exterior wall using design builder
designbuilder
« previous
1
...
1
2
...
2
next »
2
Answers
1
I have an EMS file that runs with No erros but doesn't control the output
1
I have set the heating setpoint to 26°C yet when I simulate it stops at 20°C in designbuilder
7
Votes
7
0
21
Tags
designbuilder
× 23
setpoint
× 10
zone-temperature
× 8
energyplus
× 6
ems
× 5
thermostat
× 4
openstudio
× 3
glazing
× 2
geometry
× 1
thermal-mass
× 1
schedule
× 1
error
× 1
hvac-control
× 1
heat-exchanger
× 1
radiant-heating
× 1
heating-load
× 1
zone-hvac
× 1
phase-change-material
× 1
design
× 1
weather-file
× 1
ansys
× 1
5
Badges
●
Teacher
×
1
I have set the heating setpoint to 26°C yet when I simulate it stops at 20°C in designbuilder
●
Editor
×
1
How to set a deadband so while the zone air temperature is between 22 and 26°C the heating system is off.Am using designbuilder so maybe I can do this through an EMS file
●
Student
×
1
how to create a single zone with 3 interior walls and a single exterior wall using design builder
●
Commentator
×
1
How to set a deadband so while the zone air temperature is between 22 and 26°C the heating system is off.Am using designbuilder so maybe I can do this through an EMS file
●
Supporter
×
1
when adding a water radiator in a single zone is it possible to specify on which wall the radiator is placed
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how