2017-10-22 04:17:42 -0500 | asked a question | I am using anys to create a heat exchanger containing parallel slabs. the heat exchanger is defined as a solid body i need it to be hollow to allow air flow. any ideas? I am using anys to create a heat exchanger containing parallel slabs. the heat exchanger is defined as a solid body i ne |
2017-03-13 03:52:44 -0500 | asked a question | I would like to use an Inorganic PCM that we will encapsulate using a polymer for water cooling. Any suggestion for a good PCM and a software for simulating results. We need the water to be cooled to 4 degrees from 50 degrees. In district cooling application |
2016-12-14 01:35:50 -0500 | commented question | heat gains through glazing more than losses in design builder The climate is in Austria,Graz. And yes the building is over heating even though we have natural ventilation of 1ach in summer |
2016-12-13 03:12:39 -0500 | asked a question | heat gains through glazing more than losses in design builder the window are distributed uniformly on each side of the single family house 4 on each side |
2016-12-13 01:18:56 -0500 | asked a question | Transmission losses very low using design builder I am simulating a single family house with roof the losses are low i compared with calculated results with same u-values. external wall u-value 0.24 and total heating demand for 156m² is only 17kWh/m². what could be the mistake? your help is highly appreciated |
2016-11-29 07:57:01 -0500 | asked a question | Transmission losses are not included in design builder simulation. Why? Am modeling a building GSHP 2 floors with 5 zones each. attached is the outputUnbenannt.PNG |
2016-11-28 05:38:55 -0500 | answered a question | I have an EMS file that runs with No erros but doesn't control the output I get correct results in energyplus but no change in designbuilder output |
2016-11-22 02:37:53 -0500 | asked a question | I have an EMS file that runs with No erros but doesn't control the output Schedule:Constant,Cycle,OnOff,1; AvailabilityManager:Scheduled, Packaged Rooftop Air Conditioner Availability Manager, Cycle; EnergyManagementSystem:Sensor, AptTemp, BLOCK1:ZONE1, Zone Mean Air Temperature; EnergyManagementSystem:Sensor, hSP, BLOCK1:ZONE1, Zone Thermostat Heating Setpoint Temperature; EnergyManagementSystem:Actuator, AvailSCH_Overwrite, Cycle, Schedule:Constant, Schedule Value; EnergyManagementSystem:ProgramCallingManager, Supervision, BeginTimestepBeforePredictor, HVAC_uncontolledloop_Supervision; EnergyManagementSystem:Program, HVAC_uncontolledloop_Supervision, SET Toffset = 4, IF AptTemp > (hSP - 0.01), SET AvailSCH_Overwrite = 0, ELSEIF AvailSCH_Overwrite == 0 && AptTemp >= (hSP - Toffset), SET AvailSCH_Overwrite = 0, ELSE, SET AvailSCH_Overwrite = 1, ENDIF;set.PNG |
2016-11-07 05:36:29 -0500 | asked a question | How to model core activation for a single zone using design builder When i choose internal source i can place the heating pipes after the first layer but i want the pipes embeded within the second layer. How? |
2016-10-20 07:06:09 -0500 | commented answer | Heating/cooling when out of the interval of acceptable temperatures But that only stops cooling and doesn't allow a range for heating so it will heat when ever the temp. is less than heating set point what if I want to maintain a room temp. of 22 to 25°C how to set the limit |
2016-10-20 02:42:22 -0500 | commented answer | How to set a deadband so while the zone air temperature is between 22 and 26°C the heating system is off.Am using designbuilder so maybe I can do this through an EMS file Thank you very much your comment is right but am still getting errors any idea why? |
2016-10-20 01:58:48 -0500 | commented question | How to set a deadband so while the zone air temperature is between 22 and 26°C the heating system is off.Am using designbuilder so maybe I can do this through an EMS file Hi, Thanks for commenting I have no cooling system i just want to maintain a temp. of 22-26 inside the room. Your Help is Appreciated |
2016-10-20 01:58:48 -0500 | received badge | ● Commentator |
2016-10-19 08:39:00 -0500 | received badge | ● Editor (source) |
2016-10-19 07:16:41 -0500 | asked a question | How to set a deadband so while the zone air temperature is between 22 and 26°C the heating system is off.Am using designbuilder so maybe I can do this through an EMS file |
2016-10-19 06:32:18 -0500 | commented answer | Inputting Temperature Driftpoints in EnergyPlus Did EMS work with you? if yes may you post the file here. Thank you. |
2016-10-19 03:56:10 -0500 | commented question | Thermostat Schedule Set hello Ivan, thank you for such detailed info I tried running the EMS file I have no errors but it's not effecting my simulation results. Any ideas why? Your help is much appreciated |
2016-10-18 10:52:23 -0500 | received badge | ● Teacher (source) |
2016-10-18 04:21:47 -0500 | answered a question | I have set the heating setpoint to 26°C yet when I simulate it stops at 20°C in designbuilder I changed to simple HVAC data and it works now |
2016-10-18 02:06:39 -0500 | asked a question | I have set the heating setpoint to 26°C yet when I simulate it stops at 20°C in designbuilder The system strats at 0°C and continues heating until 20 not 26 the setback temperature is also 26 as i didn't include an occupancy schedule |
2016-10-14 05:46:05 -0500 | commented question | Fatal Error- "GetSysAvailManagerInputs: Errors found in input. Preceding condition(s) cause termination" Any luck? as am having the same issue |
2016-10-14 01:24:28 -0500 | commented answer | Heating/cooling when out of the interval of acceptable temperatures what if i don't have a cooling system and i just want heating to stop at 26°C but no cooling. Thank you for your time. |
2016-10-13 02:09:39 -0500 | commented answer | How to set the starting temperature inside the zone and the range of comfortable temperatures in design builder I get severe errors and its not simulating |
2016-10-13 02:08:52 -0500 | commented answer | How to set the starting temperature inside the zone and the range of comfortable temperatures in design builder BeginTimestepBeforePredictor, HVAC_uncontolledloop_Supervision; EnergyManagementSystem:Program, HVAC_uncontolledloop_Supervision, SET Toffset = 1.00, IF AptTemp > (hSP - 0.01) && AptTemp < (hSP + 0.01), SET AvailSCH_Overwrite = 0, ELSEIF AvailSCH_Overwrite == 0 && AptTemp >= (hSP - Toffset) && AptTemp <= (hSP + Toffset), SET AvailSCH_Overwrite = 0, ELSE, SET AvailSCH_Overwrite = 1, ENDIF; |
2016-10-13 02:08:40 -0500 | commented answer | How to set the starting temperature inside the zone and the range of comfortable temperatures in design builder if i try using the Ems file for my case Schedule:Constant,Cycle,OnOff,1; ! New schedule object AvailabilityManager:Scheduled, ! Updated Availability Manager Packaged Rooftop Air Conditioner Availability Manager, Cycle; EnergyManagementSystem:Sensor, AptTemp, Thermal Zone 1, Zone Mean Air Temperature; EnergyManagementSystem:Sensor, hSP, Thermal Zone 1, Zone Thermostat Heating Setpoint Temperature; EnergyManagementSystem:Actuator, AvailSCH_Overwrite, Cycle, Schedule:Constant, Schedule Value; EnergyManagementSystem:ProgramCallingManager, Supervision, |
2016-10-13 01:14:20 -0500 | commented answer | How to set the starting temperature inside the zone and the range of comfortable temperatures in design builder Thank you for answering but is there a way to do it directly with designbuilder without exporting to energyplus. |
2016-10-12 09:24:23 -0500 | asked a question | How to set the starting temperature inside the zone and the range of comfortable temperatures in design builder I want my Zone to start at 22c and heat until the zone temperature is 26c then the sys switches off until the zone temperature is 22 and so on |
2016-10-11 07:25:00 -0500 | asked a question | I want a site with constant temperature and 0 solar radiation how to edit weather files I try weather data analysis but when i want to convert my edited csv file back to epw it says unknown source and the program terminates |
2016-10-10 02:54:33 -0500 | received badge | ● Supporter (source) |
2016-10-07 07:00:20 -0500 | commented answer | how to create a single zone with 3 interior walls and a single exterior wall using design builder Thank you that was very useful |
2016-10-07 06:54:20 -0500 | asked a question | when adding a water radiator in a single zone is it possible to specify on which wall the radiator is placed am looking at the thermal mass and the position is important |
2016-10-07 02:29:11 -0500 | asked a question | When I want to choose Heating design days the icon is frozen I have tried at building level, zone level, and site level. |
2016-10-06 19:35:04 -0500 | received badge | ● Student (source) |
2016-10-06 09:17:50 -0500 | asked a question | how to create a single zone with 3 interior walls and a single exterior wall using design builder it sets the walls to exterior by default |