Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

EnnaEnitsriK's profile - activity

2016-05-18 12:12:17 -0500 commented answer Adding extra thermal mass

Thanks!!! So smart and simple - how could I oversee that! Thanks!

2016-05-18 11:51:23 -0500 asked a question Adding extra thermal mass

Hi.

Is it possible in EnergyPlus to find an object that simply adds more thermal mass into a room?

2016-04-12 18:14:07 -0500 marked best answer Where do I set the room-air-model in OS?

Does anyone know where or if I can change the room-air-model in OpenStudio? I know how to change it in IDF-editor for EnergyPlus, but does the feature exist in OS?

2016-04-12 18:07:47 -0500 marked best answer How does energyplus read idf-files?

Hi

How does energyplus read idf-files? Does the order of e.g. materials, constructions, building information ect. matter in terms of energyplus (EP-launch) understanding the idf-file?

Thanks in advance!

/Anne

2016-04-12 18:04:37 -0500 marked best answer How important are the structure of tabs in OS?

I'm trying mostly to use OS for indoor climate simulation, and in that matter, I would like to know more about which of the tabs are most important...

I can se tab "Thermal Zone" have the zone equipment where I can define ventilation, heating, cooling and so on. Then do I need to add anything to the tab "HVAC system"?? I'm a little confused on that.

As well, whats the importance of the "facility" tab?

2016-04-12 18:01:22 -0500 marked best answer Is it possible to use the "Ideal Air Loads" in tab "Thermal Zone" instead of defining an HVAC-system, if calculating only for room temperature and surface temperatures in a room using OpenStudio?

I want to calculate the room temperature during a year in a room, so to speak a thermal indoor climate analysis (i don't care about energy use), and I think the HVAC-system-tab/air-loop-settings in OpenStudio is too advanced for my case - So is it possible to instead just use the "Ideal air loads"-button? Does anybody have a bad experience with this?

2016-03-29 03:04:22 -0500 commented answer How to model a (independent) heating source in EnergyPlus?

Thanks a lot for the opportunity but I made it work finally :)

2016-03-27 07:28:40 -0500 commented answer How to model a (independent) heating source in EnergyPlus?

continued: Do you agree? Or did I completely misunderstand the objects way of working?

2016-03-27 07:27:58 -0500 commented answer How to model a (independent) heating source in EnergyPlus?

Hey again - I hope it's alright to come back to you with a question :) I've tried to add a ZoneControl:Thermostat:OperativeTemperature object, but I get more (1021) hours below 21 degrees then before (774).. Originally I have IdealLoadAirSystem, Thermostat, duelsetpoint, design specification outdoor air, a equipment list and the connection (referring to the objects IdealLoadAirSystem requires).. but thats all needed according to what I can read from the webpage bigladder, it says: "Zone Control:Thermostatic and related set point objects also need to be included in the input file."

2016-03-26 05:08:36 -0500 commented answer How to model a (independent) heating source in EnergyPlus?

I'll read more about that object thanks! :)

2016-03-26 04:27:14 -0500 commented answer How to control the supply inlet temperature in IdealLoadAirSystem-object?

Okay, i'll try to look into making an airloop. Thanks! :) If I use OS and look at an exported idf-file from an OS-file with VAV-system, would it then be possible to know which and how many objects I need to make the air-loop correct? In your opinion :)

2016-03-26 04:22:11 -0500 commented answer How to model a (independent) heating source in EnergyPlus?

Alright :) thanks for answers!

2016-03-25 07:59:09 -0500 commented answer How to model a (independent) heating source in EnergyPlus?

Thank you for the advise and the link! I just read about "Other Equipment" in the input/output-reference, but I couldn't find a field where to define a setpoint for minimum room temperature.. Is that just me misunderstanding the object, or is that how it works?

2016-03-25 07:56:19 -0500 commented answer How to model a (independent) heating source in EnergyPlus?

Yes I very much want to, and I also do so. But from the results I can see operative room temperature at 20,5C e.g... which does not make sense to me...

2016-03-25 07:55:30 -0500 received badge  Editor (source)
2016-03-25 07:54:58 -0500 commented question How to control the supply inlet temperature in IdealLoadAirSystem-object?

Yes, I want to keep the inlet temperature at e.g. 21C, but the amount of air coming into the room to go from e.g. 2/hr to 4/hr when a cooling load occurs. Does that make sense? :)

2016-03-25 07:52:17 -0500 commented question How to model a (independent) heating source in EnergyPlus?

Does not* sorry!!

2016-03-24 07:43:06 -0500 asked a question How to control the supply inlet temperature in IdealLoadAirSystem-object?

I'm using the IdealLoadAirSystem-object in energyplus, and can see from the results, that when my internal gains increases (and I then get a cooling demand), the heating of my supply inlet temperature stops and then the room receives unheated outdoor-air e.g. at 4C.

This makes sense since IdealLoadAirObject tries to stick to the thermostat setpoint temperature (21C), but instead of decreasing the inlet temperature, I want to increase the supply air rate. How to do this? 1) Can IdealLoadAirSystem do this via specific settings, or 2) do I have to add another/new HVAC-opbejct?

The calculation is 100% thermal.

2016-03-24 06:15:00 -0500 asked a question How to model a (independent) heating source in EnergyPlus?

In energyplus, can one add an object that simply insures that the room temperature is never below a minimum?

Like a node from which heat is flowing into the zone.. Convection, radiation, both or just one, i'm not looking for surface temperature, just room temperature.

The zoneHVACbaseboard types does not work for me..

2016-03-15 15:04:03 -0500 commented answer Design Specification ZoneHVAC Sizing Object Name in ZoneHVAC:IdealLoadAirSystem

Great, I think I've got it now - thanks so much!

2016-03-15 13:09:55 -0500 commented answer Can I import a new (updated) IDF-file (my geometry) into an existing OS-file where a IDF-file already has been imported?

Okay.. :) Now I tried the three measures from the BCL, but every time I get an error that somethings (primarily construction names and material names) is missing, and so I can see in the in.idf that OS tries to make. The Name-fields/lines are empty, but the IDF that I in different ways are trying to get in, has alle the names.. I's that a typical error, or should I keep trying to find other measures?

2016-03-15 13:06:54 -0500 marked best answer Design Specification ZoneHVAC Sizing Object Name in ZoneHVAC:IdealLoadAirSystem

In EP-launch I have investigated the "ZoneHVAC:IdealLoadAirSystem" and the last field is the "Design Specification ZoneHVAC Sizing Object Name".

What does it mean for the "ZoneHVAC:IdealLoadAirSystem"'s way of working, if I activate the last field by writing a name (and of course also have specified/defined this name in a "Design Specification ZoneHVAC Sizing")??

Is it okay to not fill out this last field?

2016-03-15 13:05:24 -0500 commented answer Design Specification ZoneHVAC Sizing Object Name in ZoneHVAC:IdealLoadAirSystem

Thanks for elaborating! Just to be sure; When you write "...you could use the Design Specification Zone HVAC Sizing object...", are you then referring to the other option for defining max flow rate for cooling and heating via the fields within the actual IdealLoadAirSystem-object?

2016-03-15 10:17:07 -0500 commented answer Design Specification ZoneHVAC Sizing Object Name in ZoneHVAC:IdealLoadAirSystem

Oh great! But how does that fit with the IdealAirLoadSystem-object being a "not-sizing"-object?

2016-03-15 10:17:07 -0500 received badge  Commentator
2016-03-15 08:04:28 -0500 commented answer Can I import a new (updated) IDF-file (my geometry) into an existing OS-file where a IDF-file already has been imported?

Thanks!! Do you know if the measures you linked works with OS 1.10.0? - I can see that som of the files has e.g. OS 1.6.0 in their names..

2016-03-15 07:29:47 -0500 edited question Can I import a new (updated) IDF-file (my geometry) into an existing OS-file where a IDF-file already has been imported?

Hi.

I have an OS-model, which I started up by importing a IDF-file with my geometry. Now I have an updated version of the geometry and therefore an updated IDF-file. But when I try to import the updated IDF-file into my OS-model, OS wants me to save and close my model and makes a new model with the updated IDF-file. But then all my settings are to be entered again?? :s

How can I import a IDF-model into an existing OS-model?

I have tried doing it by using SketchUp as the geometry (in stead of a IDF-file), and this I can keed updating, and the OS-file just adds more and more as I wanted, without deleting anything I made :) .. But I'm not interested in using sketchup as my geometry-base. My geometry is in a IDF-file...