First time here? Check out the Help page!
2022-11-30 07:38:40 -0500 | received badge | ● Enthusiast |
2022-11-14 13:13:28 -0500 | edited question | Project Loose Geometry plugin bug in Open Studio Application Project Loose Geometry plug in bug Open Studio Application Hello, I have recently started to use the Openstudio Applic |
2022-11-14 13:12:13 -0500 | asked a question | Project Loose Geometry plugin bug in Open Studio Application Project Loose Geometry plug in bug Open Studio Application Hello, I have recently started to use the Openstudio Applic |
2022-11-14 13:12:07 -0500 | asked a question | Project Loose Geometry plug in bug Open Studio Application Project Loose Geometry plug in bug Open Studio Application Hello, I have recently started to use the Openstudio Applic |
2022-11-08 15:40:39 -0500 | edited question | [json.exception.type_error.304] cannot use at() with string [json.exception.type_error.304] cannot use at() with string Hello, I am using Open Studio Application 3.2.1 with Energ |
2022-11-08 15:40:39 -0500 | received badge | ● Editor (source) |
2022-11-08 15:40:13 -0500 | asked a question | [json.exception.type_error.304] cannot use at() with string [json.exception.type_error.304] cannot use at() with string Hello, I am using Open Studio Application 3.2.1 with Energ |
2021-04-27 06:58:30 -0500 | received badge | ● Supporter (source) |
2021-04-22 14:04:52 -0500 | marked best answer | Does Simple Glazing System include air films ? Hi everyone, I am using OpenStudio and the object WindowMaterial:SimpleGlazingSystem I have calculated the overall U value with WINDOW 7.7. Do i need to enter the U value with air films in that object or should I enter the U value without the air films ? According to the EngineeringReference the U value includes the film but when i look at the Report: Zone Component Load Summary at the section Fenestration Conduction in Estimated Heating Peak Load Components the value is lower than expected by around 20%, when the values for infiltration and exterior wall conduction are closed to what expected. I have noticed that the value in Fenestration Conduction varies with the wind speed value in the design day so i guess the issue comes from the air films. Or is there something else ? Thanks for your help |
2021-04-22 14:04:52 -0500 | received badge | ● Scholar (source) |
2021-04-09 08:36:12 -0500 | commented answer | Does Simple Glazing System include air films ? Thanks Keigo for your quick and detailed answer. I will look into it, maybe the shape and orientation of my building imp |
2021-04-07 17:00:55 -0500 | received badge | ● Student (source) |
2021-04-07 12:36:34 -0500 | asked a question | Does Simple Glazing System include air films ? Does Simple Glazing System include air films ? Hi everyone, I am using OpenStudio and the object WindowMaterial:Simple |