2021-04-16 00:39:58 -0500 | received badge | ● Famous Question (source) |
2017-12-11 02:43:46 -0500 | answered a question | VAV reheat coil behaving unexpectedly and leading to unmet hours VAV reheat coil undersizing in a known issue. One workaround could be to reduce Central Heating Design Supply Air Temper |
2017-10-29 05:00:55 -0500 | answered a question | SQLite query through Python returns strange variable name This is because strings retrieved from sqlite database are Unicode instead of UTF-8. Following changes should get rid of |
2017-10-27 03:41:48 -0500 | answered a question | constant outdoor air change fraction in E+ In addition to @mdahlhausen suggestion above, take a look at ZoneVentilation:DesignFlowRate |
2017-10-27 03:39:06 -0500 | answered a question | [E+] Difference between various ExternalInterface variables: in usage & fuctionality Refer to InputOutput Reference for ExternalInterface:Schedule, ExternalInterface:Actuator and ExternalInterface:Variable |
2017-10-27 03:35:15 -0500 | edited question | solve Error relating ChillerHeater in E+ solve Error relating ChillerHeater in E+ I made a idf file including ChillerHeater:Absoption:DirectFired. Error message |
2017-10-27 03:34:59 -0500 | answered a question | solve Error relating ChillerHeater in E+ This one probably requires opening an E+ issue. For the similar condition, though severe error is issued for chiller typ |
2017-10-23 22:17:53 -0500 | edited answer | Water Source Summary anomaly From OutputReportTabular.cc, totalWater = totalOnsiteWater + gatherMains + StorageChange; where gatherMains = Water Sup |
2017-10-23 13:03:51 -0500 | commented answer | Water Source Summary anomaly Tried to add some more information as to what I think is happening. StarvedVDot calculation is missing in the WaterUse.c |
2017-10-23 12:58:03 -0500 | edited answer | Water Source Summary anomaly From OutputReportTabular.cc, totalWater = totalOnsiteWater + gatherMains + StorageChange; where gatherMains = Water Sup |
2017-10-22 04:44:17 -0500 | edited answer | Water Source Summary anomaly From OutputReportTabular.cc, totalWater = totalOnsiteWater + gatherMains + StorageChange; where gatherMains = Water Sup |
2017-10-22 01:54:22 -0500 | commented answer | Water Source Summary anomaly Searching for keyword Mains Water Volume and Mains Supply Water Volume, in InputOutput Reference will show other report |
2017-10-20 13:38:29 -0500 | edited answer | IDFVersionUpdater using commandline IDFVersionUpdater can convert multiple files at once using *.lst file. Refer to AuxiliaryPrograms.pdf and search for sec |
2017-10-20 13:31:49 -0500 | edited answer | IDFVersionUpdater using commandline IDFVersionUpdater can convert multiple files at once using .lst file. Refer to AuxiliaryPrograms.pdf and search for sect |
2017-10-20 13:26:05 -0500 | commented answer | IDFVersionUpdater using commandline Several months ago, I had to convert 100s of 90.1 reference files from v8.4 to v8.7. And IDFVersionUpdater has been of g |
2017-10-20 08:11:24 -0500 | commented answer | IDFVersionUpdater using commandline If all the file names are defined in lst file, IDFVersionUpdater should be run only once to convert all of them from 8.4 |
2017-10-20 06:56:53 -0500 | answered a question | Water Source Summary anomaly From OutputReportTabular.cc, totalWater = totalOnsiteWater + gatherMains + StorageChange; where gatherMains = Water Sup |
2017-10-19 23:49:37 -0500 | answered a question | IDFVersionUpdater using commandline IDFVersionUpdater can convert multiple files at once using *.lst file. Refer to AuxiliaryPrograms.pdf and search for sec |
2017-10-16 22:35:51 -0500 | commented answer | Have you added a dish station to your quick-serve restaurant? If so, how did you specify the equipment? i.e. definitions and schedules? Unit of peak flow rate input is $m^3/s$ so it is independent of kitchen square footage. The area of kitchen in reference |
2017-10-16 22:35:39 -0500 | commented answer | Have you added a dish station to your quick-serve restaurant? If so, how did you specify the equipment? i.e. definitions and schedules? Unit of peak flow rate input is $$m^3/s$$ so it is independent of kitchen square footage. The area of kitchen in referen |
2017-10-16 22:34:54 -0500 | commented answer | Have you added a dish station to your quick-serve restaurant? If so, how did you specify the equipment? i.e. definitions and schedules? Unit of peak flow rate input is m^3/s so it is independent of kitchen square footage. The area of kitchen in reference f |
2017-10-14 13:19:43 -0500 | answered a question | Have you added a dish station to your quick-serve restaurant? If so, how did you specify the equipment? i.e. definitions and schedules? EnergyPlus example file RefBldgQuickServiceRestaurantNew2004_Chicago.idf can be referenced as shown below. WaterUse:E |
2017-10-12 05:25:10 -0500 | edited question | fluid type in EnergyPlus fluid type in EnergyPlus Hi! I want to make a plant loop consisting of WaterHeater:Mixed and Boiler:Steam. At PlantLoop |
2017-10-12 05:23:38 -0500 | answered a question | fluid type in EnergyPlus WaterHeater:Mixed and Boiler:Steam can not be on the same plant loop. Use and Source side nodes of WaterHeater:Mixed can |
2017-10-11 18:32:23 -0500 | received badge | ● Notable Question (source) |
2017-10-09 01:28:21 -0500 | edited answer | How humidity is controled in HVACTemplate:System:VAV Running simulation for one day of summer and winter each would show whether CoolReheat control is actually working or no |
2017-10-09 01:26:03 -0500 | answered a question | How humidity is controled in HVACTemplate:System:VAV Running simulation for one day of summer and winter each would show whether CoolReheat control is actually working or no |
2017-10-07 00:58:18 -0500 | answered a question | EMS Actuator using nodal values Erl variable names in EnergyManagementSystem:GlobalVariable object should not match with any other erl variable name. Ma |
2017-10-01 01:59:25 -0500 | answered a question | primary-secondary heating EnergyPlus PlantLoop object has input field Common Pipe Simulation which specifies a primary secondary configuration. Th |
2017-09-27 13:08:36 -0500 | answered a question | Severe errors when "migrating" jeplus job from energyplus 8.5 to 8.7 Two new input fields are added in ZoneCapacitanceMultiplier:ResearchSpecialobject in v8.7. Original v8.5 idf should be t |
2017-09-27 02:29:30 -0500 | answered a question | Outdoor Air Reset for Domestic Water Heater Supply Water Setpoint A workaround is as follows: EnergyManagementSystem:Program, myTempManager, !- Name SET myTempControl=(-2/3)* Outd |
2017-09-11 03:09:34 -0500 | edited answer | Zone Contaminant Source or Sink CO2 Gain seems to be wrong Following code snippet shows how these output variables are calculated for ( Loop = 1; Loop <= TotCO2Gen; ++Loop |
2017-09-11 03:06:14 -0500 | answered a question | Zone Contaminant Source or Sink CO2 Gain seems to be wrong Following code snippet shows how these output variables are calculated for ( Loop = 1; Loop <= TotCO2Gen; ++Loop |
2017-09-08 05:28:36 -0500 | answered a question | Calculating Power, Capacity, and COP from Chiller Curves Reporting above outputs at detailed frequency as opposed to hourly would show better comparison. Available capacity is c |
2017-07-23 10:06:29 -0500 | answered a question | How to generate the Chiller:Electric:ReformulatedEIR curves? This link provides modified version of curve fit tool that comes with EnergyPlus installation. It can be used to generat |
2017-07-20 22:24:18 -0500 | commented answer | How can I model SetpointManager:Warmest, with a variable Maximum Setpoint Temperature? You are right. Warmest SPM sets zone air flow rate before EMS updates the setpoint. To accomplish your above goals, I wo |
2017-07-20 05:19:22 -0500 | answered a question | How can I model SetpointManager:Warmest, with a variable Maximum Setpoint Temperature? You probably have to write a combination of EMS and warmest SPM to get this working. Snippet below may provide some help |
2017-06-09 15:02:37 -0500 | received badge | ● Popular Question (source) |
2017-03-20 06:59:31 -0500 | commented question | EnergyPlus schedules and daylight savings time My understanding is that E+ applies daylight saving time when either of these conditions are met a) if epw file has |
2017-02-17 03:18:46 -0500 | commented question | Error: ** Severe ** ProcessSurfaceVertices: Divider area exceeds glazed opening for window... Divider area is calculated as follows. Since Surface.Multiplier = 1, for HorDividers=0, VertDividers = 6, DivArea = 1.08 (as you correctly calculated). and for HorDividers=6, VertDividers = 0, DivArea = 23.4. (seems incorrect and is what E+ is calculating) Debugging idf with E+ source code or posting link to actual idf will help in seeing what is going on inside E+. |
2016-12-16 06:01:02 -0500 | commented question | Trying to find a complete object list for E+ @NickC, This excel tool parses the Energy+.idd and print out all the objects along with their required input fields. I could only do limited testing so if you find any issue while using this tool, please do let me know. All objects and required input fields for E+ versions 7.2, 8.0, 8.1, 8.2, 8.3, 8.4, 8.5, and 8.6 are also in the spreadsheet. Looks like in v 8.6, "required-field" special comment is removed from a lot of input fields. |
2016-12-15 19:43:50 -0500 | commented question | Trying to find a complete object list for E+
|
2016-12-06 20:42:16 -0500 | commented question | Temps differ for adjacent nodes |
2016-12-02 20:43:05 -0500 | received badge | ● Organizer (source) |
2016-12-02 20:36:10 -0500 | edited question | Temps differ for adjacent nodes Dear UMH folk, My EnergyPlus heating loop has two adjacent nodes that, in my mind, should have identical properties. One node is the supply side outlet node, the other is the demand side inlet node. I've confirmed via IDF review and SVG file that they are indeed adjacent ... but they have temperatures differing by several degrees C. That doesn't make sense to me. Can one of you shed some light on why that might occur? p.s., Simple, single hot water boiler loop with outdoor reset control |
2016-12-02 20:35:23 -0500 | answered a question | Temps differ for adjacent nodes |
2016-07-21 13:00:04 -0500 | commented answer | Default Condenser Loop Tower and Evaporative Fluid Cooler Design water flow rate Refer to note in the idd for |