Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

timotius.kelvin's profile - activity

2020-07-13 03:00:52 -0500 commented question control chiller compressor speed using schedule on EnergyPlus?

@Ag maybe the Compressor Flow Rate Schedule Name

2020-07-02 00:37:39 -0500 edited question control chiller compressor speed using schedule on EnergyPlus?

control chiller compressor speed using schedule How I control chiller compressor speed (RPM) using schedule?

2020-07-02 00:37:15 -0500 edited question control chiller compressor speed using schedule on EnergyPlus?

control chiller compressor speed using schedule How I control chiller compressor speed (RPM) using schedule?

2020-07-01 09:46:59 -0500 commented question control chiller compressor speed using schedule on EnergyPlus?

I only using energyplus 9.2 software.

2020-07-01 06:48:55 -0500 asked a question control chiller compressor speed using schedule on EnergyPlus?

control chiller compressor speed using schedule how i control chiller compressor speed using schedule

2020-05-08 09:45:49 -0500 edited question Control Pump Mass Flow Rate

Control Pump Mass Flow Rate I want to control the pump mass flow rate using HVACTemplate:Plant:ChilledWaterLoop with inp

2020-05-08 09:44:54 -0500 edited question Control Pump Mass Flow Rate

Control Pump Mass Flow Rate show different result I want to control the pump mass flow rate using HVACTemplate:Plant:Chi

2020-05-08 09:44:09 -0500 edited question Control Pump Mass Flow Rate

Control Pump Mass Flow Rate I want to control the pump mass flow rate using HVACTemplate:Plant:ChilledWaterLoop with inp

2020-05-08 09:43:36 -0500 edited question Control Pump Mass Flow Rate

Control Pump Mass Flow Rate I want to control the pump mass flow rate using HVACTemplate:Plant:ChilledWaterLoop with inp

2020-05-08 09:28:35 -0500 edited question Control Pump Mass Flow Rate

Control Pump Mass Flow Rate I want to control the pump mass flow rate using HVACTemplate:Plant:ChilledWaterLoop with inp

2020-05-08 08:26:22 -0500 edited question how to model on/off chiller but I only model my chiller using HVACTemplate

how to model on/off chiller but I only model my chiller using HVACTemplate I'm modelling a chilled water loop with Energ

2020-05-08 08:22:59 -0500 asked a question Control Pump Mass Flow Rate

Control Pump Mass Flow Rate I want to control the pump mass flow rate using HVACTemplate:Plant:ChilledWaterLoop with inp

2020-05-08 07:39:37 -0500 commented answer Initial value of "zone mean temperature"

Thanks a lot. Its really works too! It easy and simple

2020-05-08 07:39:23 -0500 commented answer Initial value of "zone mean temperature"

Thanks a lot. Its really works too! It easy and simple but I think it is kinda cheat the system though.

2020-05-08 07:19:36 -0500 answered a question Error in running BCVTB with E+

maybe u should look for energyplus file on BCVTB platform. try looking the file "variable.cfg" at your e+ folder. make

2020-05-06 09:36:20 -0500 edited question how to model on/off chiller but I only model my chiller using HVACTemplate

how to model on/off chiller but I only model my chiller using HVACTemplate I'm modelling a chilled water loop with Energ

2020-05-06 09:34:22 -0500 asked a question how to model on/off chiller but I only model my chiller using HVACTemplate

how to model on/off chiller but I only model my chiller using HVACTemplate I'm modelling a chilled water loop with Energ

2020-04-29 09:45:05 -0500 marked best answer Initial value of "zone mean temperature"

How to set initial value of "zone mean temperature" in Energy+. regardless of HVAC Availability schedule, zone infiltration, occupancy and weather file.

I want Energy+ start the simulate with initial zone mean room temperature at 28 Celsius.

What i get is Energy+ start it by initial 26.6 Celsius (begin simulation) maybe because of my HVAC Availability schedule.

Is there any way I can set the initial value "zone mean temperature" in Energy+?

2020-04-29 09:45:05 -0500 received badge  Scholar (source)
2020-04-29 09:44:59 -0500 commented answer Initial value of "zone mean temperature"

Thanks a lot. Its really works too! It easy and simple but I think it is kinda cheat the system though. It looks stupi

2020-04-29 09:44:56 -0500 commented answer Initial value of "zone mean temperature"

Thanks a lot! this is the information that I need. it's kinda troublesome to fill the warmup calculations just to get

2020-04-28 00:47:03 -0500 received badge  Editor (source)
2020-04-28 00:47:03 -0500 edited question Initial value of "zone mean temperature"

Initial value of "zone mean temperature" How to set initial value of "zone mean temperature" in Energy+. regardless of H

2020-04-26 04:22:48 -0500 asked a question Initial value of "zone mean temperature"

Initial value of "zone mean temperature" How to set initial value of "zone mean temperature" in Energy+. regardless of H

2020-04-26 04:22:41 -0500 asked a question Initial value of "zone mean temperature"

Initial value of "zone mean temperature" How to set initial value of "zone mean temperature" in Energy+. regardless of H

2020-04-26 01:37:35 -0500 commented question Thermostat Schedule Set

maybe you should check your "system availabilty schedule name" in your HVACTemplate. Make sure it is suit with the "sche

2020-04-25 13:12:21 -0500 received badge  Student (source)
2020-04-24 08:38:19 -0500 asked a question How to know the process energy plus controls the HVAC system using "zone thermostat control"?

how to know the process energy plus controls the HVAC system using "zone thermostat control"? I am doing chiller control

2020-04-24 04:01:29 -0500 received badge  Supporter (source)