First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
TIMO TIMO E+'s profile - overview
overview
network
karma
followed questions
activity
11
karma
follow
Registered User
member since
2024-11-02 03:55:36 -0600
last seen
2024-11-04 07:32:08 -0600
todays unused votes
29
votes left
3
Questions
12
views
1
answer
1
vote
2024-11-04 02:38:24 -0600
PmP
Why is it that when I set the output variable as "Zone Thermal Comfort Fanger Model PPD" in the EnergyPlus output variable section, there are no related CSV results appearing after parameterized simulation through Jeplus?
jeplus
ppd
energyplus
thermal-comfort
output-variable
no
views
no
answers
no
votes
2024-11-04 06:25:27 -0600
TIMO TIMO E+
"Jeplus seems unable to simulate overhangs and similar structures at present. My E+ file contains overhang elements, but I couldn't find them when importing into Jeplus." [deleted]
overhang
11
views
no
answers
no
votes
2024-11-04 07:32:02 -0600
TIMO TIMO E+
If I want to simulate different air conditioning systems in jeplus
air-conditioner
jeplus
energyplus
parametric-analysis
1
Answer
0
how can I get results for 'annual energy consumption for heating and cooling due to sensible and latent loads'?
1
Vote
1
0
11
Tags
energyplus
× 4
jeplus
× 3
output-variable
× 3
thermal-comfort
× 2
ppd
× 2
designbuilder
× 1
ideal-loads-air-system
× 1
parametric-analysis
× 1
hvac-load
× 1
overhang
× 1
air-conditioner
× 1
3
Badges
●
Rapid Responder
×
1
how can I get results for 'annual energy consumption for heating and cooling due to sensible and latent loads'?
●
Editor
×
1
Why is it that when I set the output variable as "Zone Thermal Comfort Fanger Model PPD" in the EnergyPlus output variable section, there are no related CSV results appearing after parameterized simulation through Jeplus?
●
Student
×
1
Why is it that when I set the output variable as "Zone Thermal Comfort Fanger Model PPD" in the EnergyPlus output variable section, there are no related CSV results appearing after parameterized simulation through Jeplus?
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how