2023-08-10 04:27:52 -0500 | marked best answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? I used the calculation method (UHFcalc) available in EnergyPlus to calculate the g-function response factors of the ground heat exchangers. I would like to know if there is any possible way to know the values of response factors calculated and results from using this method in energyPlus. Thank you, Regards, Kamar |
2023-08-09 13:52:03 -0500 | commented answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? Thank you very much for your help. I found the file .glhe Many thanks, Best regards, Kamar |
2023-08-09 10:32:54 -0500 | commented answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? Yes, sure. Here it is. https://drive.google.com/file/d/1T6jyA48Ak9JH8vcx18f1v0m0k1cZ9vVs/view?usp=drive_link Thank you i |
2023-08-09 10:14:57 -0500 | commented answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? I have run the older file anyway in the new version 23.1 of EP and the warning disappears. However, no eplusout.glhe was |
2023-08-09 10:04:57 -0500 | commented answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? Thank you. I installed this new version 23.1 but the file updater is not converting the older version to the new one. It |
2023-08-09 10:03:40 -0500 | commented answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? Thank you. I installed this new version 23.1 but the file updater is not the new one. Tt requests me to install new Add- |
2023-08-09 09:35:55 -0500 | commented answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? I am using 9.6.0 version of EP |
2023-08-09 07:30:26 -0500 | commented answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? Hi, I have run it again and this warning appears: The following lines are "Unused Objects". These objects are in the i |
2023-08-09 07:12:54 -0500 | commented answer | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? Thank you for your answer. Where this file should appear. Actually I am not seeing it in the output files. I added an ob |
2023-08-05 08:23:37 -0500 | received badge | ● Student (source) |
2023-08-04 09:52:28 -0500 | asked a question | Is there any way to know the g-function response factors calculated automatically using EnergyPlus? Is there any way to know the g-function response factors calculated automatically using EnergyPlus? I used the calculati |
2023-05-22 05:22:50 -0500 | commented answer | Anyone can explain how the common pipe and why is used in the plant loop? The warnings are the following: GetSpecificHeatGlycol: Temperature is out of range (too low) for fluid [WATER-GLYCOL MI |
2023-05-22 04:31:41 -0500 | commented answer | Anyone can explain how the common pipe and why is used in the plant loop? Thank you very much for your answer. In fact, I do not know what the common pipe does but after adding it I have warni |
2023-05-22 04:29:16 -0500 | marked best answer | Anyone can explain how the common pipe and why is used in the plant loop? Is there an example of the examples of energyplus files with a common pipe so I can see an example of implement it in the plant loops. Many thanks in advance, Kamar |
2023-05-19 11:40:34 -0500 | asked a question | Anyone can explain how the common pipe and why is used in the plant loop? Anyone can explain how the common pipe and why is used in the plant loop? Is there an example of the examples of energyp |
2023-05-10 15:42:42 -0500 | commented answer | Ground source heat pump system operation Thank you for your answer. In fact, it is not the goal of my model. |
2023-05-10 09:42:48 -0500 | commented answer | Ground source heat pump system operation I have tried to check them all and solved all the warning and errors of the model. However, when I enable the ASHRAE 55 |
2023-05-10 02:52:23 -0500 | commented answer | Ground source heat pump system operation Thank you very much for your answer. My last question, how can I validate my model? As a mechanical engineer what aspec |
2023-05-07 14:25:51 -0500 | received badge | ● Supporter (source) |
2023-05-07 13:33:11 -0500 | commented answer | Ground source heat pump system operation Regarding the previous question, the inlet and the outlet water temperature of the heat pump which are presented in the |
2023-05-07 13:26:44 -0500 | commented answer | Ground source heat pump system operation Thank you for your answer. I have corrected the model previously following your previous helpful comments, but I am st |
2023-05-07 06:34:40 -0500 | marked best answer | Ground source heat pump system operation I am running a model of ground source heat pump system with central forced air system in EnergyPlus, and I am obtaining the following inlet and outlet temperature curves of the heat pump cooling and heating component. How can I verify if it is working well?.! It seems strange that the inlet temperature and the outlet temperature does not match when the heat pump is not operating. Here it is a link for the two pictures and the model if anyone can help. https://drive.google.com/drive/folder... Many thanks in advance. |
2023-05-07 06:34:40 -0500 | received badge | ● Scholar (source) |
2023-05-07 06:34:29 -0500 | commented answer | Ground source heat pump system operation Many thanks for your answer. In fact, I was looking at the temperature at the system nodes 30, 31, 32 and 33 which are t |
2023-05-06 11:06:18 -0500 | asked a question | Ground source heat pump system operation Ground source heat pump system operation I am running a model of ground source heat pump system with central forced air |
2023-04-23 10:30:43 -0500 | commented question | Vertical BHE effect on heat pump system efficiency I am still obtaining unexpected results when changing the ground thermal conductivity, the length of the boreholes and t |
2023-04-23 10:30:14 -0500 | commented question | Vertical BHE effect on heat pump system efficiency I am still obtaining unexpected results when changing the ground thermal conductivity, the length of the boreholes and t |
2023-04-22 11:56:34 -0500 | commented question | Vertical BHE effect on heat pump system efficiency I am still obtaining unexpected results when changing the ground thermal conductivity, the length of the boreholes and t |
2023-04-22 11:53:25 -0500 | commented answer | How to model borehole ground heat storage/recovery in EnergyPlus Yes thank you. I will post my model there. |
2023-04-21 11:04:31 -0500 | commented answer | How to model borehole ground heat storage/recovery in EnergyPlus Dear Aaron, I am having some unexpected results when changing the ground thermal conductivity, the length of the boreho |
2023-04-21 11:04:02 -0500 | commented answer | How to model borehole ground heat storage/recovery in EnergyPlus Dear Aaron, I am having some unexpected results when changing the ground thermal conductivity, the length of the boreho |
2023-04-19 11:14:12 -0500 | commented answer | Vertical BHE effect on heat pump system efficiency Adding to this, my borehole field is not regular at all. And I do not know if the software you recommended are able to c |
2023-04-19 11:13:49 -0500 | commented answer | Vertical BHE effect on heat pump system efficiency Adding to this, my borehole field is not regular at all. And I do not know if the software you recommended are able to c |
2023-04-19 11:12:29 -0500 | commented answer | Vertical BHE effect on heat pump system efficiency Thank you Greg for your answer. In fact, I am requesting EnergyPlus (EP) to calculate the G-function response factors us |