audunbul's profile - activity

2019-06-13 00:49:52 -0500 commented answer Batteries only charges to around 70 %

I added all battery report variables, but it only reported for the design day since the yearly simulation did not run be

2019-06-13 00:48:24 -0500 commented answer Batteries only charges to around 70 %

Good reasoning about the charging time. I had used the ShopWithPVandBattery example file when I set up my file. I tried

2019-05-25 07:45:17 -0500 asked a question Batteries only charges to around 70 %

Batteries only charges to around 70 % I am simulating an off-grid building with PV-battery system in Shanghai, where I e

2019-05-06 21:54:28 -0500 commented answer Can not access output variables for battery

Thanks, it was solved when I changed Buss Type to DirectCurrentWithInverterDCStorage

2019-04-25 19:53:26 -0500 commented answer Can not access output variables for battery

Thanks, I had overlooked it. I have it included now (I have added the picture of my ElectricLoadCenter:Distribution abov

2019-04-25 19:50:53 -0500 received badge  Editor (source)
2019-04-25 19:50:53 -0500 edited question Can not access output variables for battery

Can not access output variables for battery I get the following warning: The following Report Variables were requeste

2019-04-25 19:49:57 -0500 edited question Can not access output variables for battery

Can not access output variables for battery I get the following warning: The following Report Variables were requeste

2019-04-10 06:28:12 -0500 commented answer How to model an off-grid building?

Thanks for the reply! I read that IORef says the same as you: "All demand not met by available generator capacity (or st

2019-04-10 04:08:52 -0500 received badge  Supporter (source)
2019-04-10 04:08:13 -0500 commented answer Can not access output variables for battery

Thanks for the suggestions, I forgot to mention that I had turned on Output : Diagnostics, DisplayAdvancedReportV

2019-04-10 03:31:51 -0500 asked a question Can not access output variables for battery

Can not access output variables for battery I get the following warning: The following Report Variables were requeste

2019-03-04 13:26:28 -0500 received badge  Student (source)
2019-03-04 09:46:37 -0500 asked a question How to model an off-grid building?

How to model an off-grid building? I have added Generator:Photovoltaic, ElectricLoadCenter:Generators,ElectricLoadCenter