2019-03-14 13:58:11 -0500 | asked a question | Single Stage Rooftop Unit with On/Off Fan? Single Stage Rooftop Unit with On/Off Fan? Hi All, I'm trying to use OpenStudio to create a rooftop unit having a cycli |
2019-02-12 09:01:51 -0500 | commented answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) Is there a physical/engineering explanation for this result? |
2019-02-11 18:10:15 -0500 | commented answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) They matched after setting the minimum limit to 99 |
2019-02-07 12:29:31 -0500 | commented answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) Big Picture: in most cases, the cooling energy does drop while using economizers, which is the expected outcome from usi |
2019-02-06 13:09:52 -0500 | commented answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) I set the minimum limit to 55 F (12.778 C), heating consumptions retrieved from the summary tables are as follows (GJ): |
2019-02-05 15:18:11 -0500 | commented answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) I compared both files, the economizer type was the only difference between the two. Like I said before, I'm using only |
2019-01-31 14:03:25 -0500 | commented answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) I'm running the same file 5 times using (eppy), inputs other than economizer type are fixed. High economizer limits are |
2019-01-31 13:20:09 -0500 | commented answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) Based on my understanding, heating consumption is going to differ from one timestep to the next based on the dynamic cha |
2019-01-31 11:55:30 -0500 | edited answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) I have created the suggested plot. It shows the volumetric air flow on the x-axis and the heating coil energy consumptio |
2019-01-31 11:54:56 -0500 | commented answer | Packaged Rooftop with air economizer and gas heating (question about heating consumption) I checked the supply air flow rate, it was exactly 0.982 m3/s for all economizer settings. I'll add the new plot to the |
2019-01-30 18:35:58 -0500 | received badge | ● Teacher (source) |
2019-01-30 17:23:22 -0500 | answered a question | Packaged Rooftop with air economizer and gas heating (question about heating consumption) I have created the suggested plot. It shows the volumetric air flow on the x-axis and the heating coil energy consumptio |
2019-01-27 09:44:13 -0500 | received badge | ● Student (source) |
2019-01-24 15:01:39 -0500 | asked a question | Packaged Rooftop with air economizer and gas heating (question about heating consumption) Packaged Rooftop with air economizer and gas heating (question about heating consumption) Hi all, I am solving a resear |