qiulu's profile - activity

2019-01-25 17:26:55 -0500 commented answer How to control both CO2 concentration and ventilation schedule in EMS?

Thanks for your help!

2019-01-25 17:26:20 -0500 marked best answer How to control both CO2 concentration and ventilation schedule in EMS?

Hello, I would like to do natural ventilation based on both CO2 and ventilation schedule in EMS. And I have set two Sensors in EMS and set two programs. One is for CO2 concentration (above 1000 ppm, the window will open); and another one is a time schedule for venting (night ventilation). I would like to satisfy both conditions (CO2 concentration and time schedule) at the same time. However, it didn't work. The window can only follow one Program. I was wondering if someone could answer my question? Thanks very much!

2019-01-25 05:02:07 -0500 asked a question How to control both CO2 concentration and ventilation schedule in EMS?

How to control both CO2 concentration and ventilation schedule in EMS? Hello, I would like to do natural ventilation bas

2019-01-25 01:32:39 -0500 received badge  Supporter (source)
2019-01-23 23:40:54 -0500 commented answer How to use EMS to control natural ventilation depending of indoor CO2 concentration?

Thank you so much. It runs.

2019-01-23 19:54:39 -0500 marked best answer How to use EMS to control natural ventilation depending of indoor CO2 concentration?

Hello, I would like to do is when the CO2 reaches 1000 ppm, the window will open. And I used EMS set the C02 concentration of the zone as a sensor. However, there is always an error: "unique key name not found" in the file, showing on the following. I was wondering if anyone could tell me how to create a unique name in "EnergyManagementSystem: Sensor". Thanks in advance.

 ** Severe  ** Invalid Output:Variable or Output:Meter Index Key Name =CARBON DIOXIDE
   **   ~~~   ** For Output:Variable or Output:Meter = ZONE AIR CO2 CONCENTRATION
   **   ~~~   ** Entered in EnergyManagementSystem:Sensor=CO2_CONC
   **   ~~~   ** Unique Key Name not found.
   **  Fatal  ** Errors found in processing Energy Management System input. Preceding condition causes termination.
2019-01-23 19:54:38 -0500 received badge  Scholar (source)
2019-01-23 19:54:24 -0500 commented answer How to use EMS to control natural ventilation depending of indoor CO2 concentration?

Thank you so much. It works. Do you happen to know if EMS can do CO2 and Temperature in the same time? I did the progr

2019-01-23 09:22:38 -0500 received badge  Student (source)
2019-01-23 02:15:17 -0500 asked a question How to use EMS to control natural ventilation depending of indoor CO2 concentration?

How to use EMS to control natural ventilation depending of indoor CO2 concentration? Hello, I would like to do is when t