2020-05-13 15:36:52 -0500 | asked a question | IndoorAirQualityProcedure for DCV IndoorAirQualityProcedure for DCV Hi All, Is it possible to set demand controlled ventilation based on "IndoorAirQuality |
2020-04-16 12:39:59 -0500 | edited question | OpenStudio Measure: .setFixedWindowConstruction OpenStudio Measure: .setFixedWindowConstruction Hi all, what information should be provided for “const ConstructionBas |
2020-04-16 12:37:56 -0500 | asked a question | OpenStudio Measure: .setFixedWindowConstruction OpenStudio Measure: .setFixedWindowConstruction Hi all, what information should be provided for “const ConstructionBas |
2018-09-14 15:16:52 -0500 | commented question | Zero "Zone Air Terminal Outdoor Air Volume Flow Rate" on design days How can I check it? Actually on the same day (i.e. summer design day) in the annual simulation run, the "Zone Air Termin |
2018-09-14 15:14:57 -0500 | commented question | Zero "Zone Air Terminal Outdoor Air Volume Flow Rate" on design days How can I check it? Actually on the same day (i.e. summer design day), the "Zone Air Terminal Outdoor Air Volume Flow Ra |
2018-09-14 06:17:44 -0500 | commented question | Zero "Zone Air Terminal Outdoor Air Volume Flow Rate" on design days Actually there are internal heat gains from people, lights and so on. And indoor temperature is much higher than the coo |
2018-09-13 17:20:12 -0500 | asked a question | Zero "Zone Air Terminal Outdoor Air Volume Flow Rate" on design days Zero "Zone Air Terminal Outdoor Air Volume Flow Rate" on design days Hello All, Although I've set outdoor air method in |
2018-09-12 20:20:35 -0500 | commented question | zero cooling load on summer design day My terminal HVAC units are VAV boxed. I am using standard schedules (i.e. there are internal heating gains from people, |
2018-09-12 18:08:53 -0500 | commented question | zero cooling load on summer design day My terminal HVAC units are VAV boxed. I am using standard schedules (i.e. there are internal heating gains from people, |
2018-09-12 16:11:02 -0500 | answered a question | zero cooling load on summer design day VAV boxed. I am using standard schedules (i.e. there are internal heating gains from people, lights and electric equipme |
2018-09-12 12:44:17 -0500 | asked a question | zero cooling load on summer design day zero cooling load on summer design day Hello All, I am using autosizing for hvac calculations in EnergyPlus. It gives me |
2018-07-31 13:39:06 -0500 | asked a question | Heating equipment sizing and people load Heating equipment sizing and people load Hello All, Is the internal heat gain from occupants taken into account for heat |
2018-04-19 09:35:36 -0500 | asked a question | EnergyPlus EMS: internal variable EnegyPlus EMS: internal variable Hello All, I am trying to use EMS code to define electric equipment level. But it does |
2018-02-13 21:12:52 -0500 | commented answer | Export idf with EnergyPlus measures in OpenStudio Thank you Avi. |
2018-02-13 21:12:24 -0500 | commented question | Export idf with EnergyPlus measures in OpenStudio Thank you David. |
2018-02-12 14:36:56 -0500 | received badge | ● Student (source) |
2018-02-12 14:28:41 -0500 | asked a question | Export idf with EnergyPlus measures in OpenStudio Export idf with EnergyPlus measures in OpenStudio Hello All, I am running an EnergyPlus measure in OpenStudio. My model |