First time here? Check out the Help page!
2024-03-31 01:50:28 -0500 | received badge | ● Popular Question (source) |
2023-08-16 18:16:39 -0500 | commented answer | Creating OpenStudio Server for PAT Algorithmic Analysis Yeah i didnt realize the instructions were for linux... using the set command worked. I am one step closer to getting t |
2023-08-16 15:26:03 -0500 | commented answer | Creating OpenStudio Server for PAT Algorithmic Analysis When I try to run the command through the command prompt it says "export is not recognized as an internal or external co |
2023-08-15 15:59:47 -0500 | asked a question | Creating OpenStudio Server for PAT Algorithmic Analysis Creating OpenStudio Server for PAT Algorithmic Analysis Hello, I am trying to set up a remote server to run algorithmic |
2022-11-29 12:21:13 -0500 | received badge | ● Notable Question (source) |
2022-11-29 12:21:13 -0500 | received badge | ● Popular Question (source) |
2022-11-17 13:14:34 -0500 | commented question | Zone Level Humidification Control Yes, I have humidifying setpoint schedules on the thermal zone tab. The model fails with a fatal error stating that ther |
2022-11-17 13:11:14 -0500 | commented question | Sketchup file wont translate to openstudio file Can you upload sceenshots? Typically, you shouldn't be saving any openstudio geometry as a .skp file. |
2022-11-15 13:32:34 -0500 | commented question | Sketchup file wont translate to openstudio file Are you saving as a SketchUp file .skp or using the Openstudio extensions list to save as an Openstudio file .osm? |
2022-11-15 13:28:14 -0500 | asked a question | Zone Level Humidification Control Zone Level Humidification Control I am modeling a multizone AHU with zone level reheat and humidification in Openstudio. |
2021-10-21 12:56:43 -0500 | asked a question | Thermal energy storage Chilled Water Tank With multiple chillers Thermal energy storage Chilled Water Tank With multiple chillers I am modeling a central chilled water plant with a stra |
2021-08-31 17:31:06 -0500 | commented answer | Empty eplusout.err File I'm glad it worked. Good Luck with the rest of your project. |
2021-08-30 14:56:35 -0500 | commented answer | Empty eplusout.err File Hi Alejandro, You should add this as a comment rather than an answer. It turns out that the main reason this error wa |
2021-08-16 11:34:21 -0500 | commented answer | Producing chiller efficiency curves with limited manufacture information Thanks for the helpful input. I think that the data I have is not enough to develop all three performance curves that I |
2021-08-16 11:26:15 -0500 | edited question | Producing chiller efficiency curves with limited manufacture information Producing chiller efficiency curves with limited manufacture information I'm working on a chiller comparison for a chill |
2021-08-02 15:22:32 -0500 | asked a question | Producing chiller efficiency curves with limited manufacture information Producing chiller efficiency curves with limited manufacture information I'm working on a chiller comparison for a chill |
2021-08-02 15:22:25 -0500 | asked a question | Producing chiller efficiency curves with limited manufacture information Producing chiller efficiency curves with limited manufacture information I'm working on a chiller comparison for a chill |
2021-07-23 15:58:14 -0500 | commented question | Severe Error: Air Inlet and Air Outlet Node Name Missing Did you delete CHW/HW coils from an air loop but forget to remove them from a plant loop? |
2021-07-23 13:35:02 -0500 | commented question | Water Source Heat Pump Measures Not Working I did not, but there is another measure that did what I was trying to do. The NZEHVAC measure is able to replace the exi |
2021-06-30 17:00:58 -0500 | commented question | Water Source Heat Pump Measures Not Working Thanks for the documentation. I think I've narrowed it down to a section of the "run" method make_hot_water_plant = fa |
2021-06-30 15:25:57 -0500 | asked a question | Water Source Heat Pump Measures Not Working Water Source Heat Pump Measures Not Working I downloaded three OpenStudio WSHP measures from the BCL and they all seem t |
2021-06-25 15:54:40 -0500 | asked a question | Generic Condensing Boiler From BCL Generic Condensing Boiler From BCL How do I add the Generic Condensing Boiler Natural Gas Boiler Component from the BCL |
2021-06-22 17:45:11 -0500 | asked a question | Chilled Beam with DOAS Chilled Beam with DOAS I'm trying to become familiar with modeling different HVAC system types in OpenStudio that I am g |
2021-06-22 17:45:04 -0500 | asked a question | Chilled Beam with DOAS Chilled Beam with DOAS I'm trying to become familiar with modeling different HVAC system types in OpenStudio that I am g |
2021-06-04 13:37:23 -0500 | edited question | OpenStudio Convergence Error OpenStudio Convergence Error I'm working on a project for school using OpenStudio and am receiving several errors statin |
2021-06-03 15:43:49 -0500 | edited question | OpenStudio Convergence Error OpenStudio Convergence Error I'm working on a project for school using OpenStudio and am receiving several errors statin |
2021-06-03 15:41:12 -0500 | asked a question | OpenStudio Convergence Error OpenStudio Convergence Error I'm working on a project for school using OpenStudio and am receiving several errors statin |
2021-05-25 17:40:50 -0500 | commented question | Not creating eplusout.end file I ran the in.idf and eplaunch crashed and didn't generate an eplusout.err file. This is the same issue that I was having |
2021-05-25 16:54:20 -0500 | commented question | Not creating eplusout.end file I am experiencing a similar issue. Did you have any luck in getting this resolved? |
2021-05-08 17:33:43 -0500 | marked best answer | Empty eplusout.err File Hello, I'm working on a OpenStudio Energy Model as a school project. My team and I have finished most of the model but received different errors that prevented the simulation from running. Using this forum as a resource, we were able to work through most if the errors that we received, but after running the model the last time, the .err file was blank and the model failed to run. I am unsure where to go next. What could be the reason for the .err file to be left blank? The model is a two story classroom/laboratory building. We are using Ideal Air loads for the initial analysis. |
2021-05-07 15:43:51 -0500 | commented question | Empty eplusout.err File Just sent it. Thank you! |
2021-05-07 12:55:23 -0500 | asked a question | Empty eplusout.err File Empty eplusout.err File Hello, I'm working on a OpenStudio Energy Model as a school project. My team and I have finish |
2021-04-13 19:31:02 -0500 | edited question | OpenStudio Design Day Conditions OpenStudio Design Day Conditions Can I change the design day to 1% annual cumulative frequency dry-bulb and wet-bulb te |
2021-04-13 19:29:51 -0500 | commented answer | OpenStudio Design Day Conditions Thanks for the information! My workaround was to just make a custom design day based on the weather file, however there |
2021-04-13 19:20:42 -0500 | marked best answer | OpenStudio Design Day Conditions Can I change the design day to 1% annual cumulative frequency dry-bulb and wet-bulb temperatures for cooling conditions? When I import a .ddy file the default cooling design day conditions are set to .4%. Is there a way to change this? or does the temperature, humidity, wind solar, etc. data for the 1% design condition have to be entered manually in a custom design day? My workaround was to just make a custom design day based on the weather file, however there was some confusion on what to enter for the "Humidity Indicating Conditions At Maximum Dry Bulb" for the Enthalpy "Humidity Indicating Type" design day. The weather file has the value in J/kg. When I looked up the conversion for IP units it says that it should be in BTU/lb (as expected), but the autocalculated values in this field are not calculated using the J/kg to BTU/lb conversion factor found in the Eplus documentation |
2021-04-07 18:16:31 -0500 | asked a question | OpenStudio Design Day Conditions OpenStudio Design Day Conditions Can I change the design day to 1% annual cumulative frequency dry-bulb and wet-bulb te |
2021-03-31 19:51:06 -0500 | asked a question | Cooling Energy by Load Type Cooling Energy by Load Type Does OpenStudio have the capability to categorize annual cooling energy by heat load type? W |
2021-03-31 19:09:59 -0500 | marked best answer | Air Wall Zone Mixing not compatible with new version of OpenStudio? I am modeling a warehouse that is a single space but needs to be broken into multiple thermal zones. I have created the space and zones and have downloaded the Air Wall Zone Mixing measure from the BCL. When I go to apply the measure from the apply measure now window, the modeler description and input fields are empty. Is this an issue with the new version of OpenStudio? I am using OpenStudio Application version 1.1.0 and openstudio SDK version 3.1.0. The measure says its compatible with OS versions 2.8 and later. |
2021-03-31 18:49:22 -0500 | commented answer | Air Wall Zone Mixing not compatible with new version of OpenStudio? Thanks! I am able to apply the measure now, however after applying the measure and running the simulation I get severe e |
2021-03-30 15:59:07 -0500 | asked a question | Air Wall Zone Mixing not compatible with new version of OpenStudio? Air Wall Zone Mixing not compatible with new version of OpenStudio? I am modeling a warehouse that is a single space but |
2021-01-21 13:17:10 -0500 | asked a question | How to Model Water Cooled Package Unit How to Model Water Cooled Package Unit Hello, I am trying to model A medium sized office building that has a small dat |
2020-11-01 22:04:29 -0500 | received badge | ● Popular Question (source) |
2020-10-26 17:20:26 -0500 | commented question | Sketchup Doesn't Recognize OpenStudio Model Unfortunately, the issue persist even after updating to v1.1.0 on both the OpenStudio Application and the SketchUp plugi |
2020-10-26 10:58:37 -0500 | commented question | Sketchup Doesn't Recognize OpenStudio Model I have the OpenStudio and Sefaira Plugins installed, but I have disabled Sefaira. I will give version 1.1.0 a try and le |
2020-10-19 10:33:46 -0500 | commented question | Sketchup Doesn't Recognize OpenStudio Model Whenever I open an OpenStudio model through Sketchup, its always by first opening a new sketchup model and then using th |
2020-10-16 12:02:32 -0500 | commented question | Sketchup Doesn't Recognize OpenStudio Model I am saving using the Extensions / OpenStudio / Save OSM .I am able to open the model directly through the openstudio ap |