Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

JoshuaDMartin's profile - activity

2015-02-12 12:31:18 -0500 received badge  Supporter (source)
2015-01-28 16:04:21 -0500 received badge  Teacher (source)
2014-11-13 13:55:13 -0500 commented answer Has anyone had any trouble running the EnergyPlus reference building models provided on the DOE website?

Good point. This was not immediately apparent to my team and I when we were first learning about these reference models and the E+ .idf file structure.

2014-10-16 14:47:00 -0500 commented question Has anyone had any trouble running the EnergyPlus reference building models provided on the DOE website?

I ran into this with a few files if I remember correctly. It is easily fixed by adjusting the "!- Maximum Number of Warmup Days" under the "Building" Object," (should be line 81 of the .idf file) to a higher value. Try 30, review the error file and if you are still having issues try something like 100 or 1000. If you look at the error file, you will probably find out that the convergence limit error is for a space that is not directly conditioned, such as a closet, or bathroom. In my experience, this has not seemed to have a noticeable effect on the results output.