jt1234's profile - activity

2023-12-07 06:38:22 -0500 asked a question Add ChillerElectricEIR to tertiary loop

Add ChillerElectricEIR to tertiary loop I'm trying to revive an old OpenStudio measure I wrote from a few years back tha

2020-11-04 08:31:21 -0500 commented question OpenStudio for Florida Building Code Compliance

I realize that this post is a bit dated, but I was wondering if there is any recent clarity on whether OpenStudio and/or

2020-05-01 14:09:11 -0500 answered a question Unable to start PAT Local Server

We found a temporary solution, but it looks like this issue is driven by an incorrect JavaScripCore file reference in th

2020-05-01 12:17:59 -0500 commented question Unable to start PAT Local Server

After doing some investigative work, it appears the issue comes about after upgrading to macOS Catalina. The PAT still w

2020-04-30 15:17:58 -0500 commented question Unable to start PAT Local Server

Same result with V3.0.

2020-04-29 18:59:06 -0500 asked a question Unable to start PAT Local Server

Unable to start PAT Local Server There are several of us at my firm that have been unable to initiate the Parametric Ana

2019-03-19 05:49:15 -0500 received badge  Enthusiast
2019-03-07 10:13:23 -0500 asked a question EnergyPlus Simulation Run Time Diagnostics

EnergyPlus Simulation Run Time Diagnostics I realize there are lots of posts and documents related to EPlus simulation t

2018-11-26 13:20:14 -0500 asked a question Heating airflow sizing for AirTerminal:SingleDuct:VAV:Reheat

Heating airflow sizing for AirTerminal:SingleDuct:VAV:Reheat I have a 100% OA airloop with several dozen zone level AirT

2018-09-21 09:59:26 -0500 commented answer Can the Duct E+ object be used to make a AirLoop demand-side bypass?

I'm curious if this was ever resolved? I'm currently struggling to find a reasonable way to account for a demand-side by

2018-09-20 05:55:50 -0500 commented answer Pump Pressure Rise EMS Actuator

In one example I'm working to mimic a scenario where a constant flow condenser water pump bypasses specific equipment at

2018-09-04 14:50:52 -0500 asked a question Pump Pressure Rise EMS Actuator

Pump Pressure Rise EMS Actuator The EMS Guide doesn't define the 'Pump Pressure Rise' actuator and its not entirely clea

2018-08-08 09:46:33 -0500 commented question Series Chiller - Continuous Pump Operation

The condenser water pumps ("cw pumps") are the where I'm seeing the issue. This issue isn't specific to one particular p

2018-08-01 05:48:21 -0500 asked a question Series Chiller - Continuous Pump Operation

Series Chiller - Continuous Pump Operation I'm working with OpenStudio v2.6 / EPlus V8.9. I'm setting up a primary only,

2018-07-17 15:39:58 -0500 commented answer Zone Level Humidifier

It appears this example file is setup to show a system level humidifier attached to an air loop that serves multiple zon

2018-07-17 09:57:35 -0500 commented answer Zone Level Humidifier

I have successfully developed measures for other projects that inject IDF text, but I haven't had success figuring out h

2018-07-17 09:57:04 -0500 commented answer Zone Level Humidifier

I have successfully developed measures for other projects that inject IDF text, but I haven't had success figuring out h

2018-07-17 07:01:00 -0500 asked a question Zone Level Humidifier

Zone Level Humidifier I have a multi-zone VAV air loop with ~25 independent zones modeled in OpenStudio/EP. Approximatel

2018-07-11 10:59:20 -0500 commented question EPlus ComponentCost:LineItem error - failed to match against any enum values

I had success running the model without that measure included so there is clearly something that is no longer compatible

2018-07-11 05:12:46 -0500 commented question EPlus ComponentCost:LineItem error - failed to match against any enum values

@Dustinl Are you running the 'Set Output Table to IP Units' sidecar measure by any chance when the error occurs?

2018-07-11 05:12:46 -0500 received badge  Commentator
2018-06-28 12:54:07 -0500 received badge  Teacher (source)
2018-06-28 12:48:26 -0500 answered a question Indoor Pool using EnergyPlus

Looks like its related to this: https://github.com/NREL/EnergyPlus/is... Autosizing doesn't seem to work with this syst

2018-06-26 09:15:14 -0500 commented question Indoor Pool using EnergyPlus

Looks like its related to this: https://github.com/NREL/EnergyPlus/issues/6763 Autosizing doesn't seem to work with thi

2018-06-26 09:06:44 -0500 commented question Indoor Pool using EnergyPlus

Related to this? https://github.com/NREL/EnergyPlus/issues/6763 I tired hardcoding a flow at the pump, but didn't try a

2018-06-26 08:48:21 -0500 asked a question Indoor Pool using EnergyPlus

Indoor Pool using EnergyPlus I'm working to setup a standard indoor pool system in EP following the 5ZoneSwimmingPool ex

2018-05-08 09:13:47 -0500 commented question Limit to Quantity of Chillers in EnergyPlus

I just tried, but received an error. It does look like EnergyPlus may have an equipment limit on the PlantEquipmentList:

2018-05-08 08:41:45 -0500 commented question Limit to Quantity of Chillers in EnergyPlus

Jason - I just sent you an IDF file. As I was compiling this test model I think I determined the underlying issue. Durin

2018-05-07 06:19:38 -0500 asked a question Limit to Quantity of Chillers in EnergyPlus

Limit to Quantity of Chillers in EnergyPlus Using OpenStudio I occasionally come across large data centers with chiller

2018-04-06 10:46:56 -0500 asked a question EPlus ComponentCost:LineItem error - failed to match against any enum values

EPlus ComponentCost:LineItem error - failed to match against any enum values I took an existing OpenStudio v2.4 project

2018-03-01 11:41:17 -0500 asked a question Free Cool HX with HeatExchanger:FluidToFluid

Free Cool HX with HeatExchanger:FluidToFluid I'm modeling a basic chilled water free-cooling setup that has worked in pa

2018-02-14 12:22:17 -0500 commented question Illuminance Map coordinates and lengths shift after reloading

link text Download link for the model files. I simplified the file a bit, but you should still see the same recurring i

2018-02-13 14:35:49 -0500 commented question Illuminance Map coordinates and lengths shift after reloading

Additional updates. This issue remains unresolved and I'm seeing the same issue with OpenStudio v2.4.

2017-10-20 11:07:44 -0500 commented answer Radiance measure fails at end of simulation

The partial run file directory is >12GB so I don't think a transfer is an option. However, I think you're absolutely

2017-10-20 06:34:15 -0500 commented question Radiance measure fails at end of simulation

I'm now thinking this may be a size issue. I ran a lesser quality run and the simulation gets further along (creates mos

2017-10-19 18:55:55 -0500 asked a question Radiance measure fails at end of simulation

Radiance measure fails at end of simulation I have a very large Radiance simulation (19k calculation points) that I'm ru

2017-10-18 14:27:45 -0500 commented question Illuminance Map coordinates and lengths shift after reloading

As of now I'm only seeing this issue when I save and reload within the SU plugin. I've tried to replicate the issue usin

2017-10-18 08:38:07 -0500 commented question Illuminance Map coordinates and lengths shift after reloading

I'm not sure if this helps, but here is an example of an Illuminance Map object after it was first created (left) and j

2017-10-17 19:41:02 -0500 received badge  Student (source)
2017-10-17 16:45:16 -0500 asked a question Illuminance Map coordinates and lengths shift after reloading

Illuminance Map coordinates and lengths shift after reloading I'm trying to add a series of Illuminance Maps and dayligh