2024-02-28 11:53:44 -0500 | commented answer | System design days for climate changes Got it. How did you check that in the WeatherShift files? The files that I work with are standard TMY CSV files and I'm |
2024-02-28 11:25:10 -0500 | commented answer | System design days for climate changes The link doesn't work for me and says "Forbidden You don't have permission to access / on this server." Not sure if it's |
2024-02-28 11:22:44 -0500 | commented answer | System design days for climate changes I'm not quite sure what you mean by spatial resolution, but they either use the location provided through the uploaded E |
2024-02-23 21:38:30 -0500 | edited answer | System design days for climate changes I use the future weather files generated by WeahterShift. You can upload your EPW file and define the climate change sce |
2024-02-23 21:37:38 -0500 | answered a question | System design days for climate changes I use the future weather files generated by WeahterShift. You can upload your EPW file and define the climate change sce |
2022-04-08 05:11:55 -0500 | received badge | ● Popular Question (source) |
2021-06-16 09:44:03 -0500 | commented question | Energy consumption compare to between VRF and Fan Coil System Didn't have a chance to check them in detail. Haven't noticed anything yet. Now that you made the files available, I hop |
2021-06-14 13:21:02 -0500 | commented question | Energy consumption compare to between VRF and Fan Coil System Please also share the fan coil model. |
2021-06-14 11:20:44 -0500 | commented question | Energy consumption compare to between VRF and Fan Coil System Share the file if you can. That might help. |
2021-05-06 14:58:16 -0500 | commented answer | BEopt how to select multiple heat pumps? So it's not about MSHP sizing. No, the software shows both heating and cooling loads for MSHP. If you are adding a heati |
2021-05-06 12:27:54 -0500 | commented answer | BEopt how to select multiple heat pumps? That number shows both heating and cooling for your heat pumps. You cannot get the heat pump's heating load separately. |
2021-05-05 14:24:14 -0500 | commented answer | BEopt how to select multiple heat pumps? If they are identical and cover the same floor area, then all you need to do is to split it in half. If the floor area i |
2021-05-05 11:52:18 -0500 | answered a question | BEopt how to select multiple heat pumps? If by multiple heat pumps, you are referring to more than one heating/cooling system for a single building/zone, then, a |
2021-05-05 11:52:18 -0500 | received badge | ● Rapid Responder (source) |
2021-03-24 12:06:12 -0500 | asked a question | Does EnergyPlus change windows' properties for different environmental conditions? Does EnergyPlus change windows' properties for different environmental conditions? The U-factor, SHGC, etc., are typical |
2021-03-18 10:54:15 -0500 | received badge | ● Rapid Responder (source) |
2021-03-18 10:54:15 -0500 | answered a question | creating wall fan in energyplus I think you are referring to a ceiling fan. You can watch this brief tutorial to learn more about the modeling process: |
2020-08-21 08:43:45 -0500 | answered a question | Calibrating utility data when there are owner and tenant bills If you are modeling the whole building, then you should definitely add the apartment units to common areas. However, you |
2020-06-24 15:05:25 -0500 | received badge | ● Necromancer (source) |
2020-06-24 15:05:22 -0500 | marked best answer | EnergyPlus executable file generated from source code doesn't work I'm using EnergyPlus 8.6.0 source code available on GitHub to generate an executable EP file. After following all the steps in wiki page (https://github.com/NREL/EnergyPlus/wi...), there are a few issues and confusions here. 1- The executable file generated by visual studio doesn't work properly. The window gets closed immediately after running and nothing happens afterward. I have also set the "energyplus" in visual studio as the "StartUp Project". 2- I'm not sure how the EP-Launch and IDFEditor come into play while all the new compiled files are in a separate folder (under "Build", in my case). Are they still linked? If yes, then what is the new energyplus.exe file that is generated by Visual Studio for? ... If no, then how exactly are they going to be helpful? 3- Even if I run the EP-Launch or IDFEditor it returns an error that says "MSCOMCTL.OCX is missing or invalid". btw, I use Windows and don't have administrative access on this computer. I'm not sure if I need full access to be able to do this process properly or not. I appreciate your opinions or ideas on any of these questions. |
2020-05-27 17:43:20 -0500 | commented answer | Can't find OpenStudio.exe on new version installation (v3.0) Not sure where you found that date. Here are the latest release notes for April 2020. |
2020-05-27 13:18:11 -0500 | commented answer | Run simulation problem https://www.dropbox.com/s/m9xv0uq4i1xggsq/cube%20b%C3%A9ton%20v9%20-%20revised.osm?dl=0 You probably need to update your |
2020-05-27 11:41:07 -0500 | commented answer | Run simulation problem https://www.dropbox.com/s/m9xv0uq4i1xggsq/cube%20b%C3%A9ton%20v9%20-%20revised.osm?dl=0 You probably need to update your |
2020-05-27 11:40:53 -0500 | commented answer | Run simulation problem https://www.dropbox.com/s/m9xv0uq4i1xggsq/cube%20b%C3%A9ton%20v9%20-%20revised.osm?dl=0 You probably need to update your |
2020-05-27 11:40:06 -0500 | commented answer | Run simulation problem https://www.dropbox.com/s/m9xv0uq4i1xggsq/cube%20b%C3%A9ton%20v9%20-%20revised.osm?dl=0 |
2020-05-26 16:20:25 -0500 | edited answer | Run simulation problem You should connect your space(s) to the thermal zone (s). Select the 'Spaces' tab, go to 'My Model', open the 'Thermal Z |
2020-05-26 15:57:35 -0500 | answered a question | Run simulation problem You should connect your space(s) to the thermal zone (s). Select the 'Spaces' tab, go to 'My Model', open the 'Thermal Z |
2020-05-25 12:47:04 -0500 | commented question | Run simulation problem @Mathias, you can email me the files, but sharing it on Dropbox or similar cloud storage is a better option because othe |
2020-05-24 23:14:42 -0500 | commented question | Run simulation problem You can share the error file or maybe the whole OpenStudio model. I can take a look at it. |
2020-05-19 23:49:23 -0500 | commented answer | I am using Openstudio 3.0 PAT application and when I am trying to run the tool with Energyplus measure, It is saying completely fail but i cannot see any error or warning message, and when I run it without energyplus measure it runs smoothly. All the downloaded measures are saved under this address: C:\Users\<name>\BCL You can find which folder contains y |
2020-05-19 23:19:27 -0500 | commented answer | I am using Openstudio 3.0 PAT application and when I am trying to run the tool with Energyplus measure, It is saying completely fail but i cannot see any error or warning message, and when I run it without energyplus measure it runs smoothly. I confirm that after changing FuelOil#1 and FuelOil#2 to FuelOilNo1 and FuelOilNo2, respectively, in the IDF file, the s |
2020-05-19 00:54:37 -0500 | commented question | I am using Openstudio 3.0 PAT application and when I am trying to run the tool with Energyplus measure, It is saying completely fail but i cannot see any error or warning message, and when I run it without energyplus measure it runs smoothly. I haven't used this E+ measure before, but I can take a look at your model if you could share it. |
2020-05-19 00:27:35 -0500 | answered a question | I read Openstudio 3.0 does not comes wit PAT, we need to install it separately. I have followed the instruction to download it and now I am not able to install it. Can somebody help me with this? You can download the application in here. It is called "OpenStudio PAT Release". There is no need to download the SDK un |
2020-05-19 00:26:58 -0500 | commented answer | Can't find OpenStudio.exe on new version installation (v3.0) You can download the application in here. It is called "OpenStudio PAT Release". There is no need to download the SDK un |
2020-05-16 23:23:48 -0500 | answered a question | Can't find OpenStudio.exe on new version installation (v3.0) Since April, the OpenStudio's application development and maintenance are transitioned to third parties. You can find mo |
2020-04-10 23:06:19 -0500 | commented answer | BEopt PV generation difference between site and source outputs Thanks, Eric! That makes sense. So, that black line in BEopt's outputs for source energy use shows an equivalent/virtual |
2020-04-10 22:54:10 -0500 | marked best answer | BEopt PV generation difference between site and source outputs The simulation outputs for PV electricity generation are different between source and site energy use. I see that the same conversion factor for electricity (i.e., 3.150) is applied to PV generation. Are we assuming that the PV output is fed to the grid and then fed back to the building? Even in that case, I think only the portion related to the transmission loss should be applied as opposed to the whole 3.150, which includes other factors such as inefficiencies in burning the fossil fuels. |
2020-04-08 00:42:49 -0500 | asked a question | BEopt PV generation difference between site and source outputs BEopt PV generation difference between site and source outputs The simulation outputs for PV electricity generation are |
2019-08-07 18:11:42 -0500 | commented answer | BeOpt sanity check: Energy savings with external insulation The last two models. I left the last model as the highly-insulated option and reduced the insulation in the other model. |
2019-08-06 17:52:44 -0500 | answered a question | BeOpt sanity check: Energy savings with external insulation Adam, there are a few things about your model that might be affecting the outputs. 1- The unmet loads are significantl |
2019-07-03 16:41:50 -0500 | commented answer | Demand response in BEopt Interesting! Thanks! |
2019-07-03 14:58:35 -0500 | marked best answer | Demand response in BEopt Where can I find the algorithm used in BEopt for Demand Response? I would like to know how it uses the average or max temperature to control the appliances/HVAC system. |
2019-07-03 14:58:34 -0500 | commented answer | Demand response in BEopt I see. Thanks for the clarification. Is there a method by which I can implement more complicated algorithms? Because the |
2019-07-03 14:42:42 -0500 | commented answer | Demand response in BEopt Yes, I have reviewed that page but I'm still confused about it. Let's say, I'm using a weather file for a climate zone o |
2019-07-03 13:50:17 -0500 | asked a question | Demand response in BEopt Demand response in BEopt Where can I find the algorithm used in BEopt for Demand Response? I would like to know how it u |
2019-06-06 09:21:33 -0500 | commented answer | BEOpt keeps saying there is no heating equipment or no cooling equipment when I have specified it I assume you are in the "Parametric" mode. You can switch to the "Design" mode and then right click on the "My Design" t |