2021-06-24 00:03:48 -0500 asked a question blind can not stop heat escape

blind can not stop heat escape Hello, I am modeling a automatic interior venetian blind for a small office. I notice whe

2021-06-15 10:38:17 -0500 marked best answer Daylight control only activate in office hour

In InputOutputReference guide, there is "1.15.1.1.4 Field: Availability Schedule Name". However, I am not able to find it in the SketchUp plugin. Is it only for E+ not OS? Not sure how we can schedule the daylight control. For example, I only want the daylight control to be activated between 8am-6pm to get desired light level. After office hour, even if the room is dark I don't need the electric light to get that level and it should be kept off. Is there a way to do that? Thanks.

2021-06-14 19:01:49 -0500 commented answer Daylight control only activate in office hour

Awesome. Thanks Aaron!

2021-06-14 18:57:11 -0500 commented question Can not find heating/cooling schedule

Thanks David. I probably purged schedules before the space types long time ago. Now even with the measure, the unused it

2021-06-14 15:15:33 -0500 asked a question Can not find heating/cooling schedule

Can not find heating/cooling schedule Hello, I am using Ideal Air Load with cooling/heating schedule for thermostat. How

2021-06-14 14:52:08 -0500 commented answer Daylight control only activate in office hour

Thanks Aaron! Your suggestion makes sense to me. However, I can not find availability schedule input in OS or SketchUp P

2021-06-14 13:09:42 -0500 asked a question Daylight control only activate in office hour

Daylight control only activate in office hour In InputOutputReference guide, there is "1.15.1.1.4 Field: Availability Sc

2021-04-05 09:50:55 -0500 received badge  Student (source)
2021-03-14 09:26:37 -0500 commented answer Components and Space Type and Construction Set Wizard for ASHRAE 90.1-2013 in OpenStudio

Ok I find that I can modify the parameters of the walls/floors/roofs to meet ASHRAE 2013 standard. The overall U-value c

2021-03-13 14:38:35 -0500 marked best answer Components and Space Type and Construction Set Wizard for ASHRAE 90.1-2013 in OpenStudio

Hello, I am new here. I have couple of questions about the Space Type and Construction Set Wizard for 90.1-2013.

  1. The "Space Type and Construction Set Wizard for ASHRAE 90.1-2013" is not in Sketchup plugin so I try to download it in the OS. I think the download measure directly inside OS has a glitch. It shows nothing under ""whole building" but I am able to download Space Type and Construction Set Wizard from the website. My OS version is openstudioapplication-1.1.1-alpha.

  2. I have the Space Type and Construction Set Wizard measure successfully loaded in OS (thanks to this post) and a new Construction Sets is created showing 90.1-2013. However, the constructions show up under this Construction Set look suspecious. For example, under Interior Surface Constructions I now have "Typical Interior Wall" and "Typical Interior Floor". But other constructions from BCL component have specific label with them like "ASHRAE 189.1-2009 EXTWall Mass ClimateZone 1-8". I am thinking maybe the Space Type and Construction Set Wizard just generate a 90.1-2013 construction set, but not actual constructions/components? I can't find components which labeled as ASHRAE 90.1-2013 on BCL either. Where can I find them? I've read some posts that they were underdevelopment but I am not sure if it is still the case.

Thanks everyone.

2021-03-13 14:38:35 -0500 received badge  Scholar (source)
2021-03-13 14:38:27 -0500 received badge  Supporter (source)
2021-02-28 19:05:18 -0500 commented answer Components and Space Type and Construction Set Wizard for ASHRAE 90.1-2013 in OpenStudio

Thanks David. How about the exterior parts? Walls: Typical Insulated Exterior Mass Wall R-14.08 Floors: Typical Insula

2021-02-26 08:40:02 -0500 asked a question Components and Space Type and Construction Set Wizard for ASHRAE 90.1-2013 in OpenStudio

Components and Space Type and Construction Set Wizard for ASHRAE 90.1-2013 in OpenStudio Hello, I am new here. I have co

2021-02-25 08:43:45 -0500 commented question Building Component Library Slow or Unresponsive

Hello, I am also trying to download components directly inside OS but it does not responding. The progress bar at the bo