2024-01-31 09:29:35 -0500 | asked a question | Heat Recovery Not Working Heat Recovery Not Working I have heat recovery set up on my DOAS air loop. But when I look at the html report, it is |
2022-08-05 00:08:21 -0500 | commented answer | Dehumidification Not Working for DX Two Stage With Humidity Control Ah! Can't believe I missed that. The measure runs now |
2022-07-27 23:11:59 -0500 | commented answer | Dehumidification Not Working for DX Two Stage With Humidity Control Ah! Can't believe I missed that. The measure runs now but not seeing a reduction in RH in the zone. |
2022-07-27 21:47:34 -0500 | commented answer | Dehumidification Not Working for DX Two Stage With Humidity Control Thanks Eric. I appreciate the thorough walkthrough of the steps. I hate to impose more but I am still getting an error |
2022-07-26 21:00:23 -0500 | commented answer | Dehumidification Not Working for DX Two Stage With Humidity Control Thanks Eric! I am admittedly a noob when it comes to utilizing measures.... I have had experience running them in OS but |
2022-07-26 00:00:26 -0500 | edited question | Dehumidification Not Working for DX Two Stage With Humidity Control Dehumidification Not Working for DX Two Stage With Humidity Control I am running a simulation using DX Two Stage With Hu |
2022-07-26 00:00:26 -0500 | received badge | ● Editor (source) |
2022-07-25 23:58:04 -0500 | asked a question | Dehumidification Not Working for DX Two Stage With Humidity Control Dehumidification Not Working for DX Two Stage With Humidity Control I am running a simulation using DX Two Stage With Hu |
2022-07-19 17:33:54 -0500 | commented answer | Peak Heating vs Boiler Sizing Yes, there is only one boiler for the entire high rise. The boiler capacity is as listed, and is about 8x the size of th |
2022-07-13 20:11:28 -0500 | asked a question | Peak Heating vs Boiler Sizing Peak Heating vs Boiler Sizing I am running a large parametric simulation of different ECMs using Openstudio/Energy Plus |
2022-07-13 20:11:20 -0500 | asked a question | Peak Heating vs Boiler Sizing Peak Heating vs Boiler Sizing I am running a large parametric simulation of different ECMs using Openstudio/Energy Plus |
2021-01-24 11:14:23 -0500 | received badge | ● Student (source) |
2021-01-23 17:45:45 -0500 | asked a question | How can I add WSHP coils on DOAS Open Studio? How can I add WSHP coils on DOAS Open Studio? I have been using WSHP as zone equipment, but is there a way to add WSHP c |