2024-01-31 09:29:35 -0500 asked a question Heat Recovery Not Working

Heat Recovery Not Working I have heat recovery set up on my DOAS air loop. But when I look at the html report, it is

2022-08-05 00:08:21 -0500 commented answer Dehumidification Not Working for DX Two Stage With Humidity Control

Ah! Can't believe I missed that. The measure runs now

2022-07-27 23:11:59 -0500 commented answer Dehumidification Not Working for DX Two Stage With Humidity Control

Ah! Can't believe I missed that. The measure runs now but not seeing a reduction in RH in the zone.

2022-07-27 21:47:34 -0500 commented answer Dehumidification Not Working for DX Two Stage With Humidity Control

Thanks Eric. I appreciate the thorough walkthrough of the steps. I hate to impose more but I am still getting an error

2022-07-26 21:00:23 -0500 commented answer Dehumidification Not Working for DX Two Stage With Humidity Control

Thanks Eric! I am admittedly a noob when it comes to utilizing measures.... I have had experience running them in OS but

2022-07-26 00:00:26 -0500 edited question Dehumidification Not Working for DX Two Stage With Humidity Control

Dehumidification Not Working for DX Two Stage With Humidity Control I am running a simulation using DX Two Stage With Hu

2022-07-26 00:00:26 -0500 received badge  Editor (source)
2022-07-25 23:58:04 -0500 asked a question Dehumidification Not Working for DX Two Stage With Humidity Control

Dehumidification Not Working for DX Two Stage With Humidity Control I am running a simulation using DX Two Stage With Hu

2022-07-19 17:33:54 -0500 commented answer Peak Heating vs Boiler Sizing

Yes, there is only one boiler for the entire high rise. The boiler capacity is as listed, and is about 8x the size of th

2022-07-13 20:11:28 -0500 asked a question Peak Heating vs Boiler Sizing

Peak Heating vs Boiler Sizing I am running a large parametric simulation of different ECMs using Openstudio/Energy Plus

2022-07-13 20:11:20 -0500 asked a question Peak Heating vs Boiler Sizing

Peak Heating vs Boiler Sizing I am running a large parametric simulation of different ECMs using Openstudio/Energy Plus

2021-01-24 11:14:23 -0500 received badge  Student (source)
2021-01-23 17:45:45 -0500 asked a question How can I add WSHP coils on DOAS Open Studio?

How can I add WSHP coils on DOAS Open Studio? I have been using WSHP as zone equipment, but is there a way to add WSHP c