2016-03-18 07:54:30 -0500 answered a question OS Ground Slab Pre-Processor Error

Thank you for your anwser. I'm not familiar with BCL, but I found an Energy Conservation Measure named "AEDG K12 - SlabAndBasement" that runs the EnergyPlus slab or basement pre-processor to calculate monthly ground temperatures. Here's the link : https://bcl.nrel.gov/node/82249

I will try that and come back to give some feedback.

2016-03-18 04:18:23 -0500 received badge  Supporter (source)
2016-03-17 12:54:41 -0500 received badge  Student (source)
2016-03-17 09:37:28 -0500 asked a question OS Ground Slab Pre-Processor Error

Hi everyone,

I'd like to apply the outside boundary condition "GroundSlabPreprocessorAverage" to a floor surface in OpenStudio (OS 1.10.5 and E+ V8.5). But the simulation fails, and I get this message in eplusout.err :

* Severe * BuildingSurface:Detailed="SURFACE 1", invalid Outside Boundary Condition="GROUNDSLABPREPROCESSORAVERAGE". * ~~~ * The ExpandObjects program has not been run or is not in your EnergyPlus.exe folder.

I tried to scan for tools but it didn't solve the problem. Any idea ?