First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
edixon16's profile - overview
overview
network
karma
followed questions
activity
368
karma
follow
Registered User
member since
2015-12-08 10:38:39 -0600
last seen
2020-01-09 13:34:23 -0600
todays unused votes
30
votes left
10
Questions
1k
views
1
answer
9
votes
2017-03-21 09:24:20 -0600
Aaron Boranian
How to model regeneration desiccant wheel on DOAS
openstudio
desiccant
dehumidification
doas
energyplus
522
views
1
answer
4
votes
2018-05-08 18:34:00 -0600
efrainpuerto
Hot Gas Reheat in OpenStudio
openstudio
heating-coil
reheat
1k
views
2
answers
4
votes
2016-04-19 16:07:52 -0600
Chris Jones
how do I determine U-factor for spandrel for LEED energy model?
leed
1k
views
1
answer
3
votes
2017-05-16 11:18:46 -0600
edixon16
How to model process cooling with ASHRAE 90.1 App G Baseline system 5 or 6
ashrae-90.1
appendix-g
process-load
525
views
1
answer
3
votes
2016-01-21 10:56:54 -0600
Chris Jones
OpenStudio and Radiance lighting schedule export
radiance
openstudio
schedule
daylighting
lighting
245
views
no
answers
3
votes
2016-02-03 13:11:43 -0600
edixon16
central heat pump with one chiller heater [closed]
energyplus
heat-pump
chiller-heater
607
views
1
answer
3
votes
2016-01-25 12:13:37 -0600
edixon16
node assignment errors in E+
energyplus
node-connection
255
views
1
answer
2
votes
2017-08-31 11:04:00 -0600
MatthewSteen
Problem with modeling the InletSideMixer AirTerminal with a FCU ZoneHVAC in OpenStudio
fan-coil-unit
openstudio
277
views
2
answers
1
vote
2016-01-21 14:31:55 -0600
rpg777
Radiance simulation fails in OpenStudio v1.9.4
radiance
openstudio
error
617
views
2
answers
1
vote
2017-12-12 20:46:10 -0600
bbrannon4
Which software can model a low temp VAV with PFP boxes.
equest
energyplus
ies-ve
vav
trane-trace
2
Answers
2
Radiance simulation fails in OpenStudio v1.9.4
1
Output Variable for Single Object in OS
5
Votes
4
1
28
Tags
openstudio
× 15
radiance
× 8
energyplus
× 6
daylighting
× 5
lighting
× 5
schedule
× 5
leed
× 3
error
× 3
doas
× 2
appendix-g
× 2
ashrae-90.1
× 2
dehumidification
× 2
heating-coil
× 2
reheat
× 2
fan-coil-unit
× 2
node-connection
× 2
process-load
× 2
desiccant
× 2
equest
× 1
ies-ve
× 1
heat-pump
× 1
openstudio-measure
× 1
vav
× 1
bcl
× 1
output-variable
× 1
material
× 1
trane-trace
× 1
chiller-heater
× 1
9
Badges
●
Teacher
×
1
Radiance simulation fails in OpenStudio v1.9.4
●
Editor
×
1
Radiance simulation fails in OpenStudio v1.9.4
●
Scholar
×
1
node assignment errors in E+
●
Supporter
×
1
node assignment errors in E+
●
Commentator
×
1
●
Student
×
1
Hot Gas Reheat in OpenStudio
●
Critic
×
1
how do I determine U-factor for spandrel for LEED energy model?
●
Organizer
×
1
node assignment errors in E+
●
Popular Question
×
3
How to model process cooling with ASHRAE 90.1 App G Baseline system 5 or 6
How to model regeneration desiccant wheel on DOAS
how do I determine U-factor for spandrel for LEED energy model?
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how