First time here? Check out the
Help
page!
Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Hi there! Please sign in
help
tags
users
badges
ALL
UNANSWERED
Ask Your Question
jaklloyd's profile - overview
overview
network
karma
followed questions
activity
237
karma
follow
Registered User
member since
2020-06-28 10:37:24 -0600
last seen
2023-12-01 02:07:54 -0600
todays unused votes
30
votes left
10
Questions
1k
views
2
answers
3
votes
2020-07-08 10:55:49 -0600
David Goldwasser
Cannot download components from BCL in OpenStudio Application, if downloaded direct from website how can I import them into the application?
openstudio
bcl
592
views
1
answer
3
votes
2020-12-02 11:06:44 -0600
David Goldwasser
How do I view the total heat transfer coefficient through surfaces in OpenStudio/EnergyPlus?
heat-transfer
energyplus
openstudio
output-variable
1k
views
1
answer
2
votes
2020-11-24 19:44:27 -0600
shorowit
How does EnergyPlus calculate floor U-values?
energyplus
u-factor
ground-heat-transfer
616
views
1
answer
2
votes
2020-08-18 05:04:58 -0600
jaklloyd
Using OpenStudio Results Measure as an 'always run measure' causes crash
openstudio-measure
please-use-existing-tags
688
views
1
answer
2
votes
2020-09-13 17:46:12 -0600
__AmirRoth__
OpenStudio - If I change the wall construction to be thicker on a base model, do I have to also change the geometry to match this?
openstudio
construction
geometry
536
views
1
answer
1
vote
2020-08-26 04:30:43 -0600
jaklloyd
Using BCL OpenStudio Results SI Measure causes simulation failure
openstudio
openstudio-measure
please-use-existing-tags
432
views
no
answers
1
vote
2020-11-11 12:52:11 -0600
jaklloyd
Can I use "Site:GroundTemperature:FCfactorMethod" as monthly ground temperature inputs for ground floor heat loss?
openstudio
ground-heat-transfer
ground-temperature
energyplus
267
views
1
answer
1
vote
2020-08-07 07:35:06 -0600
jaklloyd
Changing construction in openstudio application causes simulation to fail
openstudio
construction
construction-set
168
views
no
answers
1
vote
2020-11-08 09:29:06 -0600
jaklloyd
How can I create a construction with a user input specific u-value?
openstudio-measure
u-factor
construction
thermal-bridge
2
views
no
answers
no
votes
2020-07-10 08:53:14 -0600
jaklloyd
OpenStudio Application adiabatic walls create error in running energy simulation [deleted]
openstudio
adiabatic
boundary-condition
simulation
error
3
Answers
3
Using OpenStudio Results Measure as an 'always run measure' causes crash
2
Using BCL OpenStudio Results SI Measure causes simulation failure
2
Changing construction in openstudio application causes simulation to fail
4
Votes
4
0
23
Tags
openstudio
× 26
openstudio-measure
× 18
construction
× 13
please-use-exi...
× 12
energyplus
× 11
ground-heat-transfer
× 10
u-factor
× 9
geometry
× 6
ground-temperature
× 5
bcl
× 4
thermal-bridge
× 4
construction-set
× 3
output-variable
× 2
heat-transfer
× 2
slab
× 1
residential
× 1
aedg
× 1
boundary-condition
× 1
error
× 1
openstudio-sdk
× 1
openstudio-standards
× 1
simulation
× 1
adiabatic
× 1
8
Badges
●
Editor
×
1
How does EnergyPlus calculate floor U-values?
●
Supporter
×
1
Cannot download components from BCL in OpenStudio Application, if downloaded direct from website how can I import them into the application?
●
Student
×
1
Cannot download components from BCL in OpenStudio Application, if downloaded direct from website how can I import them into the application?
●
Popular Question
×
2
Cannot download components from BCL in OpenStudio Application, if downloaded direct from website how can I import them into the application?
How does EnergyPlus calculate floor U-values?
●
Self-Learner
×
1
Using OpenStudio Results Measure as an 'always run measure' causes crash
●
Teacher
×
1
Changing construction in openstudio application causes simulation to fail
●
Scholar
×
1
Cannot download components from BCL in OpenStudio Application, if downloaded direct from website how can I import them into the application?
●
Commentator
×
1
Using BCL OpenStudio Results SI Measure causes simulation failure
Site design and logo: Copyright © 2015 Big Ladder Software LLC. All rights reserved.
The
Unmet Hours
and
Big Ladder
names and logos are trademarks of Big Ladder Software LLC.
User contributions licensed under the
Creative Commons Attribution Share Alike 3.0 License
.
Powered by
Please note: Unmet Hours requires javascript to work properly, please enable javascript in your browser,
here is how