Question-and-Answer Resource for the Building Energy Modeling Community
Get started with the Help page
Ask Your Question

Revision history [back]

You have to create an object in Output:VariableDictionary class with Key Field value being IDF to make sure .rdd (Report Data Dictionary) and .mdd (Meter Data Dictionary) files are created during simulation. Hope this helps.