Zone volume is reported in the eio file. The data looks like this:

! <Zone Information>,Zone Name,North Axis {deg},Origin X-Coordinate {m},Origin Y-Coordinate {m},Origin Z-Coordinate {m},Centroid X-Coordinate {m},Centroid Y-Coordinate {m},Centroid Z-Coordinate {m},Type,Zone Multiplier,Zone List Multiplier,Minimum X {m},Maximum X {m},Minimum Y {m},Maximum Y {m},Minimum Z {m},Maximum Z {m},Ceiling Height {m},Volume {m3},Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall},Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST}, Floor Area {m2},Exterior Gross Wall Area {m2},Exterior Net Wall Area {m2},Exterior Window Area {m2}, Number of Surfaces, Number of SubSurfaces, Number of Shading SubSurfaces,  Part of Total Building Area
Zone Information, ZONE_01,0.0,0.00,0.00,0.00,10.05,15.05,2.00,1,1,1,0.00,20.10,0.00,30.10,0.00,4.00,4.00,2400.00,TARP,DOE-2,600.00,281.20,281.20,0.00,6,0,0,Yes
Zone Information, ZONE_02,0.0,0.00,0.00,0.00,50.15,15.05,6.00,1,1,1,20.10,80.20,0.00,30.10,4.00,8.00,3.98,7199.88,TARP,DOE-2,1799.97,721.60,721.60,0.00,6,0,0,Yes
Zone Information, ZONE_03,0.0,0.00,0.00,0.00,50.15,15.05,2.00,1,1,1,20.10,80.20,0.00,30.10,0.00,4.00,4.00,7199.88,TARP,DOE-2,1799.97,601.20,601.20,0.00,6,0,0,Yes