When I've encountered this error I've been able to fix it by increasing the Fraction Lost. If only 5% the electric equipment load is converted to waste heat, then I would set the fraction lost to 0.95 and the remaining heat fractions to 0, which will result in a convective fraction of 0.05 to the zone.