kbk78's profile - activity

2023-05-15 13:29:42 -0500 received badge  Popular Question (source)
2022-06-24 12:06:13 -0500 asked a question Listing of coils allowed in air loop

Listing of coils allowed in air loop Is there a listing of coils allowed in a central air loop. I am trying replace the

2022-03-30 09:56:29 -0500 asked a question SetpointManager:MixedAir Reference node name in Blow-through fan placement

SetpointManager:MixedAir Reference node name in Blow-through fan placement I am trying to setup a blow-through vav airha

2019-10-16 14:07:04 -0500 asked a question Equipment Sizing report differences

Equipment Sizing report differences Could someone provide the differences between the "Equipment Summary", "HVAC Sizing

2019-10-07 11:52:25 -0500 commented answer Specifiying cooling coil and baseboard heater capacity

Are there any plans to address this in the near future.

2019-05-08 10:54:00 -0500 commented answer Transitioning PNNL prototype IDF files to EnergyPlus 9.1.0?

@mike765 you will need to install energyplus version 8.9 and use the version updater that comes with it. Then use versio

2019-05-06 16:05:18 -0500 received badge  Teacher (source)
2019-05-03 18:47:29 -0500 answered a question Transitioning PNNL prototype IDF files to EnergyPlus 9.1.0?

I see that version 9.1.0 has trouble transitioning some older version EnergyPlus Files. But the transition works fine wi

2019-04-12 09:39:52 -0500 commented answer How to determine custom chiller performance curves with correct coefficients?

What should we do for the partload ratio curve EIRFPLR. Also can the chilled water supply temperature remain constant he

2019-04-02 09:14:37 -0500 asked a question Hot water loop load reset

Hot water loop load reset What is the best way to simulate a Loads reset option so as to supply at the lowest temperatur

2018-12-06 16:16:23 -0500 asked a question Monthly cooling coil sensible outputs.

Monthly cooling coil sensible outputs. I am trying to obtain the monthly sensible cooling coil energy for the cooling co

2018-11-08 09:32:15 -0500 marked best answer Pump head influence on cooling load

If we have the pump "Fraction of Motor Inefficiencies to the Fluid Stream" set to 0, why would the pump head have an effect on the cooling load.

In the attached, energy plus version 9, test file that uses purchased cooling the "cooling load" changed from 1,018,159 kBtu to 990,412 kBtu . The only thing I changed was to zero out the pump head.

C:\fakepath\tb.idf.bmp

2018-11-07 10:54:19 -0500 commented answer Pump head influence on cooling load

From the manual: ShaftPower = PumpPower * PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower)

2018-11-07 08:36:53 -0500 commented answer Pump head influence on cooling load

From the manual: ShaftPower = PumpPower * PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower)

2018-11-07 07:33:49 -0500 commented answer Pump head influence on cooling load

From the manual: ShaftPower = PumpPower * PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower)

2018-11-07 07:33:35 -0500 commented answer Pump head influence on cooling load

From the manual: ShaftPower = PumpPower  PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower)

2018-11-07 07:33:17 -0500 commented answer Pump head influence on cooling load

From the manual: ShaftPower = PumpPower  PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower) *

2018-11-06 14:41:13 -0500 asked a question Pump head influence on cooling load

Pump head influence on cooling load If we have the pump "Fraction of Motor Inefficiencies to the Fluid Stream" set to 0,

2018-10-15 08:54:12 -0500 commented answer Specifiying cooling coil and baseboard heater capacity

So the only way to ensure the cooling coil capacity matches with a predetermined system size is to make sure that the lo

2018-10-12 10:05:11 -0500 asked a question Specifiying cooling coil and baseboard heater capacity

Specifiying cooling coil and baseboard heater capacity The Coil:Cooling:Water does not seem have a way specify the capac

2018-08-16 08:28:31 -0500 received badge  Enthusiast
2018-08-10 11:16:46 -0500 asked a question AirLoopHVAC:UnitaryHeatCool application for single zone

AirLoopHVAC:UnitaryHeatCool application for single zone To model a constant volume system when would I choose a cav syst

2018-01-22 14:55:54 -0500 received badge  Citizen Patrol (source)
2017-12-15 09:40:12 -0500 commented answer Fan power accounting for a DOAS system with DCV

Thanks for your advice. Here is what appears to be working right: Use VAV fan system for the DOAS. Specify the demand

2017-12-15 09:39:09 -0500 commented answer Fan power accounting for a DOAS system with DCV

Thanks for your advice. Here is what appears to be working right: 1. Use VAV fan system for the DOAS 2. Specify the de

2017-12-15 09:33:35 -0500 commented answer Fan power accounting for a DOAS system with DCV

Thanks for your advice. Here is what I did and appears to be working right. 1) Use VAV fan system for the DOAS 2) Speci

2017-11-30 11:38:37 -0500 edited question Fan power accounting for a DOAS system with DCV

Fan power accounting for a DOAS system with DCV It appears that DOAS system with DCV acts as a constant volume system an

2017-11-29 10:17:56 -0500 edited question Fan power accounting for a DOAS system with DCV

Fan power accounting for a DOAS system with DCV It appears that DOAS system with DCV acts as a constant volume system an

2017-11-29 10:16:23 -0500 edited question Fan power accounting for a DOAS system with DCV

Fan power accounting for a DOAS system with DCV It appears that DOAS system with DCV acts as a constant volume system an

2017-11-29 09:25:49 -0500 asked a question Fan power accounting for a DOAS system with DCV

Fan power accounting for a DOAS system with DCV It appears that DOAS system with DCV acts as a constant volume system an

2017-11-20 14:01:20 -0500 asked a question SolarCollector performance data

SolarCollector performance data The solar Collector performance data listed in SolarCollector.idf dataset do not appear

2017-10-20 09:27:18 -0500 commented answer IDFVersionUpdater using commandline

Looking to run IDFVersionUpdater from the "commandline" and automate the process for repeated usage (whenever I export a

2017-10-20 09:26:52 -0500 commented answer IDFVersionUpdater using commandline

Looking to run IDFVersionUpdater from the "commandline" and automate the process for repeated usage (whenever I export a

2017-10-20 07:37:44 -0500 commented question IDFVersionUpdater using commandline

running python on windows.

2017-10-20 07:26:41 -0500 commented answer IDFVersionUpdater using commandline

So essentially we would need to call each Transition-VA-B-C-to-D-E-F.exe sequentially for each intermediate versions if

2017-10-19 17:20:18 -0500 edited question IDFVersionUpdater using commandline

IDFVersionUpdater using commandline I have multiple idf files in version 8.4 that I want to update to version 8.8. Doing

2017-10-19 17:19:52 -0500 asked a question IDFVersionUpdater using commandline

IDFVersionUpdater using commandline I have multiple idf files in version 8.4 that I want to update to version 8.8. Doing

2017-08-16 15:43:28 -0500 commented answer Designbuilder/EnergyPlus Relief fan

@Raghu, question is about modeling a relief fan not about modeling economizer. The return fan on the AHU moves the retur

2017-08-11 07:58:44 -0500 edited question Designbuilder/EnergyPlus Relief fan

Designbuilder/EnergyPlus Relief fan How do I setup a relief fan on the AHU in designbuilder or energyplus. The fan would

2017-08-11 07:58:01 -0500 asked a question Designbuilder/EnergyPlus Relief fan

Designbuilder/EnergyPlus Relief fan Is it possible to setup a relief fan on the AHU in designbuilder or energyplus. The

2017-07-11 08:46:50 -0500 marked best answer PackagedTerminalAirConditioner prevent Outdoor air during night cycle

I am setting up a PackagedTerminalAirConditioner to run on constant fan during the day and cycle the fan at night. The system also provides outside air and looking to close the outside air dampers when the fan cycles at night. How could I achieve this?

The setup I have below does cycle the fan at night but also brings in outside air during night fan cycling.

ZoneHVAC:PackagedTerminalAirConditioner,
   zone1 PTAC,                  ! Component name
   On 24/7,                     ! Availability schedule
   zone1 PTAC Return,           ! Air inlet node to heat pump; also a zone exhaust node
   zone1 PTAC Supply Inlet,     ! Air outlet node to heat pump; also a zone inlet node
   OutdoorAir:Mixer,            ! Outdoor air mixer object type
   zone1 PTAC Outdoor Air Mixer,! Outdoor air mixer name
   autosize,                ! Supply air flow rate during cooling operation (m3/s)
   autosize,                    ! Supply air flow rate during heating operation (m3/s)
   autosize,           ! Supply air flow rate when no heating or cooling is needed (m3/s)
   autosize,                    ! Outdoor air flow rate during cooling operation (m3/s)
   autosize,             ! Outdoor air flow rate during heating operation (m3/s)
   autosize,          ! Outdoor air flow rate when no heating or cooling is needed (m3/s)
   Fan:OnOff,                   ! Type of supply fan
   zone1 PTAC Supply Fan,       ! Name of supply fan
   Coil:Heating:Gas,            ! Type of heating coil
   zone1 PTAC Heating Coil,     ! Name of heating coil
   Coil:Cooling:DX:SingleSpeed, ! Type of cooling coil
   zone1 PTAC DX Cooling Coil,  ! Name of cooling coil
   DrawThrough,                 ! Fan placement
   Fan cycle mode sch;          ! Supply air fan operating mode schedule

Schedule:Compact,Fan cycle mode sch,
   on/off,
   Through: 12/31,
   For: Weekdays SummerDesignDay,
   Until: 06:00,0.0,
   Until: 20:00,1.0,
   Until: 24:00,0.0,
   For: Saturday WinterDesignDay,
   Until: 06:00,0.0,
   Until: 18:00,1.0,
   Until: 24:00,0.0,
   For: Sunday Holidays AllOtherDays,
   Until: 24:00,0.0;
2017-07-07 16:30:25 -0500 edited question PackagedTerminalAirConditioner prevent Outdoor air during night cycle

PackagedTerminalAirConditioner prevent Outdoor air during night cycle I am setting up a PackagedTerminalAirConditioner t

2017-07-07 16:28:33 -0500 asked a question PackagedTerminalAirConditioner prevent Outdoor air during night cycle

PackagedTerminalAirConditioner prevent Outdoor air during night cycle I am setting up a PackagedTerminalAirConditioner t

2016-11-07 17:18:02 -0500 commented answer Constant volume system, design temperature influence.

The two models are Identical except for the change in the zone sizing temperature. There is no cooling in the model.

I do not know why it would control to different temperatures in either case. Maybe there is some numerical instability and there is some impact as to what end of the deadband it is controlled to. A small change may be acceptable. But a 7% change does seem quite high, Would you agree.

2016-11-07 09:45:29 -0500 commented answer Constant volume system, design temperature influence.

Sorry, I don't understand what your answer intends to convey. Why is anything other than the fan power changing.

To your point about improbable model, I originally had a proper LEED model with heatpump heating and cooling. Found the savings jump 10% with changes just to the zone sizing temperature. To debug the same I created a very simple electric heating only model to minimize influence of other parameters.

Moreover, Why should it matter weather the model is probable or not?

2016-10-31 08:51:22 -0500 commented question Constant volume system, design temperature influence.

@Tian, As I indicated I zeroed out the fan energy. the outputs attached indicate no fan energy consumed. For some reason there is a 7% change in the heating subcategory.