2024-05-17 11:40:00 -0500 edited answer Building was Built in the 70s What would I use for Design OA and Infiltration

For window AC, use PTAC. For the unit ventilators, I would use PTAC with outdoor air supply. If the unit ventilators ha

2024-05-17 11:39:20 -0500 answered a question Building was Built in the 70s What would I use for Design OA and Infiltration

For window AC, use PTAC. for the unit ventilators, I would use either PTAC with outdoor air supply. If the unit ventila

2024-05-12 15:07:02 -0500 answered a question Design Builder Heating Coil Nominal Capacity

I assume it is the output heating value. Capacity usually refers to the output heat transfer.

2024-05-05 09:56:34 -0500 received badge  Self-Learner (source)
2024-05-01 12:29:39 -0500 edited question mixed water loop flow issues

mixed water loop flow issues Hello all, We design water source heat pump systems for most of our projects. I often get

2024-05-01 12:29:39 -0500 received badge  Editor (source)
2024-04-29 07:05:36 -0500 asked a question mixed water loop flow issues

mixed water loop flow issues Hello all, We design water source heat pump systems for most of our projects. I often get

2024-03-20 08:11:47 -0500 commented answer designbuilder simulation error

Neo, you can also use the designbuilder support team to help you.

2024-03-19 20:12:10 -0500 commented answer designbuilder simulation error

Hi Neo. Confirm that the zones which have the heated floor component in detailed hvac also have the correct ground floo

2024-03-18 08:50:50 -0500 commented answer designbuilder simulation error

you need to edit the ground floor assembly "heated floor - internal" to get to the construction assembly dialog. rt cli

2024-03-18 08:11:30 -0500 commented question "Why do outcomes differ between EnergyPlus simulations and manual calculations, despite using identical inputs, including equipment wattage and fraction-based usage schedules?

This question will require some more specification. What calculations are your referring to? heating and cooling desig

2024-03-17 18:46:17 -0500 commented answer designbuilder simulation error

I'm referring to the ground floor construction layer assembly dialog. There is tab on this dialog called "internal sour

2024-03-16 13:57:30 -0500 answered a question designbuilder simulation error

hello, I'm assuming that you want to model a radiant heated floor. You need to ensure that the internal source is checke

2024-03-16 13:57:30 -0500 received badge  Rapid Responder (source)
2024-03-11 19:35:02 -0500 answered a question Anyone know how to make a split AC system on Energyplus

I use PTHP. It's a zone level piece of equipment and you won't have to deal with the air loop branches.

2024-03-04 07:05:40 -0500 answered a question carbon equivalent vs CO2e

Evangelos at DesignBuilder support provided an answer for me. He confirms that EnergyPlus provides Carbon Equivalent, a

2024-02-29 06:57:10 -0500 asked a question carbon equivalent vs CO2e

carbon equivalent vs CO2e Hello all, I have some clients who assign a social impact cost ($) based on metric tons of CO

2024-01-29 17:42:23 -0500 received badge  Rapid Responder (source)
2024-01-29 17:42:23 -0500 answered a question Reporting occupancy schedules (energyplus)

How about Zone,Average,People Occupant Count?

2024-01-23 11:01:40 -0500 commented question Outdoor swimming pool with swimmingpool:indoor object

Thanks Willy. I've already implemented the indoor pool object. Modelling the pool equipment is out of our scope, but I

2024-01-22 14:03:15 -0500 asked a question Outdoor swimming pool with swimmingpool:indoor object

Outdoor swimming pool with swimmingpool:indoor object Hello everyone, I'm trying to use the swimmingpool:indoor object

2023-12-12 09:31:49 -0500 commented answer Enthalpy Energy Recovery plus Sensible Heat Recovery for Reheat

Thanks Keigo! I'm a design builder user and I think that feature is locked out.

2023-12-11 19:09:16 -0500 answered a question Enthalpy Energy Recovery plus Sensible Heat Recovery for Reheat

I don't think you can add dual enthalpy wheels, but you could simply use the manufacturers reported overall effectivenes

2023-12-05 18:20:51 -0500 answered a question Heat pipe system OpenStudio

A heat pipe is a refrigeration loop that does not require a compressor. As your image shows, it straddles the cooling c

2023-12-05 18:20:51 -0500 received badge  Rapid Responder (source)
2023-05-24 10:35:16 -0500 commented answer How to Model Range Hood with Make-up Air

Hi Keigo, 1. If the kitchen equipment under the hood is 10kW, then I enter 10kW (with a schedule) for the kitchen exhaus

2023-05-23 20:55:02 -0500 received badge  Rapid Responder (source)
2023-05-23 20:55:02 -0500 answered a question How to Model Range Hood with Make-up Air

Hey Keigo, I usually create a "kitchen exhaust fan" zone, with virtual partitions, inside the kitchen zone. I include a

2023-05-15 12:20:45 -0500 commented question Creating a MVHR system for residential application

Do you really have a residence with a central ERV (MVHR) system that has VAV boxes? Or do you have zone ERVs (MVHR). E

2023-05-13 17:53:54 -0500 received badge  Commentator
2023-05-13 17:53:54 -0500 commented question Modeling Ceiling fan or circulation fan in Designbuilder or EnergyPlus

Hi Selmar, After reading your post, it is not obvious to me that you have used the existing DesignBuilder help and tutor

2023-05-05 19:22:28 -0500 answered a question What is the output variable for Electricity Usage in kWh or kW?

Here you go: https://bigladdersoftware.com/epx/docs/9-4/input-output-reference/group-zone-forced-air-units.html#zone-pa

2023-05-05 19:22:28 -0500 received badge  Rapid Responder (source)
2023-05-04 14:10:18 -0500 answered a question Water to Air heat pump COP Curves

Hi JME, I use the DesignBuilder zone water-to-air heat pump which uses equation fit DX cooling and heating coils. The r

2023-05-04 14:10:18 -0500 received badge  Rapid Responder (source)
2023-05-02 11:25:36 -0500 commented question HeatPump:PlantLoop:EIR objects not operating with geo connection

Hello Abarker, I use centeral water to water heat pumps all the time, but I exclusively use the Type - equation fit. De

2023-05-02 10:46:40 -0500 commented answer How to model and size ASHP and GSHP HVAC system in DesignBuilder?

You can connect the DHW to the heat pump heating loop by adding the DHW loop and changing the water heater type to "indi

2023-05-02 10:46:11 -0500 commented answer How to model and size ASHP and GSHP HVAC system in DesignBuilder?

Hi Konstantinos, OK. In DesignBuilder, you can easily add water-to-water heat pumps right from the HVAC System level vi

2023-04-30 20:30:23 -0500 answered a question Calculating Infiltration Reliably

Here in Vermont, the commercial building code calls for a maximum infiltration of 0.3CFM/ft2@75 Pa. Since this is a cod

2023-04-30 20:10:37 -0500 answered a question How to model and size ASHP and GSHP HVAC system in DesignBuilder?

Hello Konstantinos, Please confirm that you want to model zone level terminal units and not central ASHPs and central GS

2023-04-19 12:55:32 -0500 commented answer Vertical BHE effect on heat pump system efficiency

Hi Qamar, Yes, GLD has the option to configure custom borefield layouts and then it will calculate the G-function for th

2023-04-18 11:19:47 -0500 received badge  Rapid Responder (source)
2023-04-18 11:19:47 -0500 answered a question Vertical BHE effect on heat pump system efficiency

Hi Qamar, Have you loaded a G-function .idf file from Ground Loop Design (GLD) software or Ground Loop Heat Exchanger (

2022-07-22 23:45:51 -0500 answered a question Multiple runperiods in EnergyPlus

Hi Long, I'm pretty sure that is what the "accelerate" feature does when using the JESS JEPlus EnergyPlus server. You c

2022-06-09 18:23:44 -0500 commented answer How to model a split unit air conditioner in DesignBuilder?

When using detailed HVAC, I use the PTHP object to model split systems. The DX cooling coil is still air cooled, so if

2022-06-01 09:40:31 -0500 received badge  Enthusiast
2021-11-09 10:08:04 -0500 received badge  Supporter (source)
2021-10-11 12:11:59 -0500 commented answer Cooling coil sizing difference

No. I know that this happens because it is a warning in the energyplus error file.

2021-10-07 07:56:26 -0500 commented answer Cooling coil sizing difference

I should clarify, that this comment is for terminal units (zone level VRF or WSHP) with a DOAS system ducted directly to

2021-10-05 12:09:08 -0500 answered a question Cooling coil sizing difference

Good afternoon, I'm not following this exactly, as I have been using Trane Trace 3D+, but I ran into a situation where t