2024-05-10 15:12:37 -0500 commented question How to turn off the heating component (heating load) for VRF systems in openstudio.

You could try hard sizing the rated heating capacity and airflow to a very small number close to zero. This is a hack I

2024-05-02 15:51:57 -0500 commented question Disabling default Output:Meter in OpenStudio

By timestep frequency are you referring to the zone timestep or the system (HVAC) timestep? Zone timestep can be modifie

2024-05-01 14:56:00 -0500 commented answer Performance improvement for openstudio-hpxml

"Limit requests for timeseries output (e.g., --hourly, --daily, --timestep arguments) and limit the number of output var

2024-05-01 14:49:09 -0500 commented answer Defining an Always-Open Entrance Exposed to Outdoor Conditions

I am currently doing some refrigerated warehouse modeling. Have you tried looking at the RefrigeratedWarehouse example m

2024-05-01 14:42:35 -0500 commented question How can I obtain the meter.csv file using the EnergyPlus Python API?

See if this documentation can help. https://nrel.github.io/EnergyPlus/api/python/_modules/datatransfer.html#DataExchang

2024-04-11 14:50:36 -0500 answered a question Is there away to obtain the GHG/CO2 emissions in openstudio/energyplus?

You can do this in post processing assuming you know the grid intensities and fuel emissions factors. There are also sou

2024-04-11 14:50:36 -0500 received badge  Rapid Responder (source)
2024-03-26 15:28:52 -0500 commented answer Error when simulating the "RefrigeratedWarehouse" example

Hello! I am looking to model refrigerated warehouses for an industry partner, preferrably in SoCal climate. Do you know

2024-03-26 15:28:13 -0500 commented answer Error when simulating the "RefrigeratedWarehouse" example

Hello! I am looking to model refrigerated warehouses for an industry partner, preferrably in SoCal climate. Do you know

2024-03-26 15:27:13 -0500 answered a question Error when simulating the "RefrigeratedWarehouse" example

Hello! I am looking to model refrigerated warehouses for an industry partner, preferrably in SoCal climate. Do you know

2023-12-13 15:32:20 -0500 answered a question TMYx for resstock

You can specify custom weather files through the weather_station_epw_filepath argument in options_lookup. Example: wea

2023-12-13 15:32:20 -0500 received badge  Rapid Responder (source)
2023-12-13 15:24:23 -0500 commented question TMYx for resstock

Maybe this source can provide insight. https://www.ibpsa.us/ask-a-modeler/ask-a-modeler-what-is-tmyx-and-how-does-it-di

2023-12-08 16:37:37 -0500 commented question PAT Measurer Editor not working

Atom is a good text editor for BEM stuff, I've found.

2023-12-07 16:19:02 -0500 commented question How to add ZoneHVAC:IdealLoadsAirSystem to OpenStudio Model

Have you tried finding a measure on the BCL? When I tried adding Ideal Air Loads to OpenStudio workflows in the past, t

2023-12-05 18:22:25 -0500 edited answer buildstock.csv files

I believe they are one and the same file. I can only speak to running ResStock using the buildstock_local command. Depe

2023-12-05 18:21:09 -0500 edited answer buildstock.csv files

I believe they are one and the same file. I can only speak to running ResStock using the buildstock_local command. Depe

2023-12-05 18:20:16 -0500 edited answer buildstock.csv files

I believe they are one and the same file. I can only speak to running ResStock using the buildstock_local command. Depe

2023-12-05 18:19:29 -0500 received badge  Rapid Responder (source)
2023-12-05 18:19:29 -0500 answered a question buildstock.csv files

I believe they are one and the same file. I can only speak to running ResStock using the buildstock_local command. Depe

2023-12-05 07:43:22 -0500 marked best answer ResStock Turn HVAC Off in Apply Upgrade Error

Hi,

I am using ResStock v2.2.4, OpenStudio v2.9.0, and EnergyPlus v9.2.

My housing_characteristics tsv files are edited to have the following distributions:100% Propane in Heating Fuel.tsv and 100% SEER 15 Central AC in HVAC System Cooling.tsv.

This means I am fixing the baseline HVAC equipment.

I am trying to use PAT to turn off HVAC equipment, keeping all the other building characteristics in the sample the same.

I have done this by specifying in the Apply Upgrade Measure Option 1 field;

HVAC System Heating Propane|None

and similarly in the Apply Upgrade Measure Option 2 field:

HVAC System Cooling|None

Both of these parameter|option pairs I sourced from options_lookup.tsv.

Apply Upgrade Measure

When I ran my simulation, all of my columns in results.csv in localResults were blank, and I could not find an enduse_timeseries.csv file in any of my data_point.zip folders.

Any idea why this is happening?

2023-12-04 18:59:49 -0500 commented question TimeseriesCSVExport Measure ResStock

Does that mean it’s not sampling at all?

2023-12-04 18:38:35 -0500 commented question ResStock- Running small-scale projects locally

Have you tried using buildstockbatch instead?

2023-12-04 18:07:06 -0500 edited question ResStock Turn HVAC Off in Apply Upgrade Error

ResStock Turn HVAC Off in Apply Upgrade Error Hi, I am using ResStock v2.2.4, OpenStudio v2.9.0, and EnergyPlus v9.2.

2023-12-04 17:51:45 -0500 answered a question Heat Pump's electricity consumption in ResStock

It's probably because you set HVAC System Heating Electricity:None. That is probably why you are getting electricity_hea

2023-11-13 18:34:18 -0500 commented answer How does "Temperature Difference Between Cutout And Setpoint" affect Unmet Hours?

Ok, that definition of unmet load hours is more specific than ASHRAE 90.1, makes sense. In that case, you don't have any

2023-11-13 16:27:10 -0500 commented answer How does "Temperature Difference Between Cutout And Setpoint" affect Unmet Hours?

If you look at your plots for zone temperature vs setpoint for 0 delta C and 0.5 delta C, you can see that when the heat

2023-11-13 14:42:56 -0500 asked a question Buildstockbatch yml Heat Pump upgrade specification

Buildstockbatch yml Heat Pump upgrade specification I'm using ResStock 3.1.0 to model HVAC electrification in Maine. Sc

2023-11-02 16:59:24 -0500 commented answer Include an output variable in ResStock Parquet files

Try iterating through results_timeseries.csv and creating your own concatenated parquet file? That's probably faster tha

2023-11-01 19:05:38 -0500 edited answer Include an output variable in ResStock Parquet files

Previous versions of ResStock let you specify EnergyPlus output variables to report beyond ResStock's default variables,

2023-11-01 19:04:58 -0500 edited answer Include an output variable in ResStock Parquet files

Previous versions of ResStock let you specify EnergyPlus output variables to report beyond ResStock's default variables,

2023-11-01 19:03:20 -0500 edited answer Include an output variable in ResStock Parquet files

Previous versions of ResStock let you specify EnergyPlus output variables to report beyond ResStock's default variables,

2023-11-01 19:02:47 -0500 edited answer Include an output variable in ResStock Parquet files

Previous versions of ResStock let you specify EnergyPlus output variables to report beyond ResStock's default variables,

2023-11-01 19:00:56 -0500 commented question Include an output variable in ResStock Parquet files

Are you referring to the average of an individual building's timeseries or an average timeseries across multiple buildin

2023-11-01 19:00:03 -0500 commented question Include an output variable in ResStock Parquet files

Are you referring to the average of an individual building's timeseries or an average timeseries across multiple buildin

2023-11-01 18:59:47 -0500 commented question Include an output variable in ResStock Parquet files

Are you referring to the average of an individual building's timeseries or an average timeseries across multiple buildin

2023-11-01 18:59:23 -0500 edited question Include an output variable in ResStock Parquet files

Include an output variable in ResStock Parquet files Hi, How can we include a specific output variable in ResStock fin

2023-11-01 18:59:16 -0500 edited question Include an output variable in ResStock Parquet files

Include an output variable in ResStock Parquet files Hi, How can we include a specific output variable in ResStock fin

2023-11-01 18:56:39 -0500 edited answer Include an output variable in ResStock Parquet files

Previous versions of ResStock let you specify EnergyPlus output variables to report beyond ResStock's default variables,

2023-11-01 18:56:14 -0500 edited answer Include an output variable in ResStock Parquet files

Previous versions of ResStock let you specify EnergyPlus output variables to report beyond ResStock's default variables,

2023-11-01 18:55:23 -0500 answered a question Include an output variable in ResStock Parquet files

Previous versions of ResStock let you specify EnergyPlus output variables to report beyond ResStock's default variables,

2023-11-01 18:55:23 -0500 received badge  Rapid Responder (source)
2023-11-01 18:40:08 -0500 commented question Include an output variable in ResStock Parquet files

Are you referring to the average of a individual building's timeseries or an average timeseries across multiple building

2023-10-23 23:50:43 -0500 received badge  Rapid Responder (source)
2023-10-23 23:50:43 -0500 answered a question ResStock Water Heater Options: Condensing or Non-Condensing?

Based on internet research it seems like gas-fired instantaneous (tankless) water heaters have UEFs up to 0.82. In Res

2023-10-23 19:09:34 -0500 asked a question ResStock Water Heater Options: Condensing or Non-Condensing?

ResStock Water Heater Options: Condensing or Non-Condensing? I'm using the latest version of ResStock and buildstockbatc

2023-10-03 19:36:33 -0500 received badge  Famous Question (source)
2023-01-18 15:00:26 -0500 received badge  Popular Question (source)
2023-01-18 15:00:26 -0500 received badge  Notable Question (source)
2022-09-21 11:26:17 -0500 marked best answer Setting annual ground temp in PAT project

Hi,

I am using OpenStudio v2.9.0, EnergyPlus v9.2, and ResStock v2.2.4.

I would like to override the default E+ ground temp of 18 deg C and set the ground temp equal to the indoor setpoint of 70 deg F.

Is there a OpenStudio or EnergyPlus measure I can add to my PAT workflow to do this? I am not able to edit the IDF file directly, since it is automatically generated through OS-PAT.