2018-07-16 16:54:40 -0500 edited answer Designbuilder/EnergyPlus Relief fan

I found your question because I have the same one. In Energy Plus, I was able to add a relief fan as a component on the

2018-07-16 16:53:31 -0500 answered a question Designbuilder/EnergyPlus Relief fan

I found your question because I have the same one. In Energy Plus, I was able to add a relief fan as a component on the

2018-05-17 10:16:27 -0500 commented answer Error importing ESO file

Also check if you have used “Detailed” reporting frequency for any of the requested output variables in the INP file. I’

2018-04-24 19:28:19 -0500 asked a question How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling

How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling I have a model with so

2018-04-24 10:58:56 -0500 edited question How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling

How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling My model has electric,

2018-04-24 10:56:10 -0500 asked a question How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling

How to prevent Energy Plus Heat-Only Fan Coil Heating Coil from operating during call for cooling My model has electric,

2018-04-16 01:08:44 -0500 commented answer Water condenser low temperature, chiller heat recovery

@Aaron Boranian: Okay, I found and followed the approach illustrated in the diagram "Two Tank Solar Heating System Diagr

2018-04-16 01:06:54 -0500 commented answer Water condenser low temperature, chiller heat recovery

@Aaron Boranian: Okay, I found and followed the approach illustrated in the diagram "Two Tank Solar Heating System Diagr

2018-04-16 01:05:39 -0500 commented answer Water condenser low temperature, chiller heat recovery

@Aaron Boranian: Okay, I found and followed the approach illustrated in the diagram "Two Tank Solar Heating System Diagr

2018-04-15 13:44:44 -0500 commented answer Water condenser low temperature, chiller heat recovery

@Aaron Boranian: I don't grasp how heat can be moved from the preheat waterheater with zero heating capacity (PreH WH)

2018-04-15 13:44:01 -0500 commented answer Water condenser low temperature, chiller heat recovery

@Aaron Boranian: I don't grasp how heat can be moved from the preheat waterheater with zero heating capacity (PreH WH)

2018-04-15 13:43:00 -0500 commented answer Water condenser low temperature, chiller heat recovery

@Aaron Boranian: I don't grasp how heat can be moved from the preheat waterheater with zero heating capacity (PreH WH)

2018-04-03 16:01:55 -0500 commented question Why could the EnergyPlus Run Status reported Elapsed Time not equal the Total elapsed clock time?

@David Goldwasser, thanks for this idea. The file is located on local drive of my laptop.

2018-03-28 11:34:25 -0500 commented answer What is the best hardware setup to minimize run time?

@Neal Kruis, Specifically how would one diagnose item #3.Memory, to determine if it is an issue?

2018-03-28 11:17:36 -0500 asked a question Why could the EnergyPlus Run Status reported Elapsed Time not equal the Total elapsed clock time?

Why could the EnergyPlus Run Status reported Elapsed Time not equal the Total elapsed clock time? I have an energy plus

2018-03-16 09:17:05 -0500 edited question What does the EnergyPlus warning "Inside surface heat balance did not converge" mean?

What does the EnergyPlus warning "Inside surface heat balance did not converge" mean? I have an Energy Plus file with th

2018-03-16 09:16:32 -0500 edited question What does the EnergyPlus warning "Inside surface heat balance did not converge" mean?

What does the EnergyPlus warning "Inside surface heat balance did not converge" mean? I have an Energy Plus file with th

2018-03-15 10:51:40 -0500 commented answer What does the EnergyPlus warning "Inside surface heat balance did not converge" mean?

@Avi, thanks for pointing me to that post, which indicates that increasing the timestep may be a solution. I had not fou

2018-03-15 10:51:17 -0500 commented answer What does the EnergyPlus warning "Inside surface heat balance did not converge" mean?

@Avi, thanks for pointing me to that post, which indicates that increasing the timestep may be a solution. I had not fou

2018-03-14 23:55:18 -0500 received badge  Associate Editor (source)
2018-03-14 23:55:18 -0500 edited answer Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

I did some experimentation and found that once I split the IDF file into two halves (in a text editor) I was able to sav

2018-03-14 23:52:33 -0500 marked best answer Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

I have an IDF file that I exported from Design Builder (v.5.3.4.004). The Version listed in the IDF is "8.6.0.001". I would like to open this file in IDFEditor, and save it to get the objects formatted (grouped by class and in the IDF editor format.) When I open it with the IDFEditor v8.6.0, I got a warning that the file format is incompatible with the .IDD file being used, and with the IDFEditor version. I edited the Version to be "8.6" in my text editor, and that warning ceased. The IDF file appears to run fine using EPLaunch v8.6.0 (I am running it now: it was read with no issues....and still simulating fine so far).

BUT, when I try to save the file, it aborts during the process with the error: "Run-time error '9': Subscript out of range", once I click "Okay" on that error, the IDFEditor quits. (I can open the new IDF file that I was attempting to save, and it does contain a incomplete portion of the IDF.

Any ideas how I can solve this?

2018-03-14 23:52:31 -0500 edited answer Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

I did some experimentation and found that once I split the IDF file into two halves (in a text editor) I was able to sav

2018-03-14 16:18:01 -0500 edited question What does the EnergyPlus warning "Inside surface heat balance did not converge" mean?

What does the EnergyPlus warning "Inside surface heat balance did not converge" mean? I have an Energy Plus file with th

2018-03-14 16:17:11 -0500 commented answer Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

Thanks for the help @JasonGlazer!

2018-03-14 16:16:27 -0500 asked a question What does the EnergyPlus warning "Inside surface heat balance did not converge" mean?

What does the EnergyPlus warning "Inside surface heat balance did not converge" mean? I have an Energy Plus file with th

2018-03-13 13:49:32 -0500 commented answer PG&E Cool Tools Chiller tool- Generating Performance Curve E+

@Anna Osborne Brannon, I just noticed that there is a tool in the PreProcess folder of the Energy Plus installation that

2018-03-10 17:30:27 -0500 edited answer Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

I did some experimentation and found that once I split the IDF file into two halves (in a text editor) I was able to sav

2018-03-10 10:16:42 -0500 answered a question Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

I did some experimentation and found that once I split the IDF file into two halves (in a text editor) I was able to sav

2018-03-10 01:36:26 -0500 edited question Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

Why does IDF Editor issue error "Run-time error '9': Subscript out of range" aborting on Save-as? I have an IDF file tha

2018-03-10 01:28:47 -0500 edited question Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

Why does IDF Editor issue error "Run-time error '9': Subscript out of range" on Save-as? I have an IDF file that I expor

2018-03-10 01:23:24 -0500 edited question Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

Why does IDF Editor issue error "Run-time error '9': Subscript out of range" on Save-as? I have an IDF file that I expor

2018-03-10 01:23:04 -0500 edited question Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

Why does IDF Editor issue error "Run-time error '9': Subscript out of range" on Save-as? I have an IDF file that I expor

2018-03-10 01:22:31 -0500 edited question Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

Why does IDF Editor issue error "Run-time error '9': Subscript out of range"? I have an IDF file that I exported from De

2018-03-10 01:21:53 -0500 asked a question Why does IDF Editor issue error "Run-time error '9': Subscript out of range," aborting on Save-as?

Why does IDF Editor issue error "Run-time error '9': Subscript out of range"? I have an IDF file that I exported from De

2018-03-01 15:03:43 -0500 marked best answer What air terminal unit types are allowed on a AirLoopHVAC:Unitary system?

I see that the diagrams in the section of the I/O reference on AirLoopHVAC:UnitarySystemshow only AirTerminal:SingleDuct:Uncontrolled. I have a file built by a colleague (which runs) that uses AirTerminal:SingleDuct:VAV:NoReheat for a zone served by an AirLoopHVAC:UnitarySystem. I am wondering if this is problematic.

2018-03-01 12:40:07 -0500 asked a question What air terminal unit types are allowed on a AirLoopHVAC:Unitary system?

What air terminal unit types are allowed on a AirLoopHVAC:Unitary system? I see that the diagrams in the section of the

2018-03-01 12:13:47 -0500 commented answer Single Zone VAV serving multiple zones

@dradair, did you have any luck finding a solution? I'm looking at the same problem. Did you consider using an AirLoopHV

2018-02-17 15:34:00 -0500 commented question Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating?

...The reheat coil in one of the two zones, for example, is at an autosized cap. of ~109kW, whereas the zone predicted s

2018-02-17 14:22:38 -0500 commented question Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating?

@rraustad: I looked at the variables you suggested above and there is a large spike in the Zone Predicted Sensible Load

2018-02-17 14:12:13 -0500 commented question Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating?

@TomB: Thanks for the suggestion. Good idea to check that. Oddly, the pattern of high mixed air flows during morning war

2018-02-16 01:59:33 -0500 commented question Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating?

Thanks for the help, @rraustad. I found the reason Economizer is not working: "MinimumFlowWithBypass" is input for the f

2018-02-16 01:58:26 -0500 commented question Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating?

Thanks for the help, @rraustad. I found the reason Economizer is not working: "MinimumFlowWithBypass" is input for the f

2018-02-15 12:35:47 -0500 edited question Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating?

Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating? I've been tryi

2018-02-15 12:27:39 -0500 edited question Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating?

Why is this Energy Plus VAV system operating at maximum airflow when all connected zones require heating? I've been tryi