2023-05-15 13:29:42 -0500 | received badge | ● Popular Question (source) |
2022-06-24 12:06:13 -0500 | asked a question | Listing of coils allowed in air loop Listing of coils allowed in air loop Is there a listing of coils allowed in a central air loop. I am trying replace the |
2022-03-30 09:56:29 -0500 | asked a question | SetpointManager:MixedAir Reference node name in Blow-through fan placement SetpointManager:MixedAir Reference node name in Blow-through fan placement I am trying to setup a blow-through vav airha |
2019-10-16 14:07:04 -0500 | asked a question | Equipment Sizing report differences Equipment Sizing report differences Could someone provide the differences between the "Equipment Summary", "HVAC Sizing |
2019-10-07 11:52:25 -0500 | commented answer | Specifiying cooling coil and baseboard heater capacity Are there any plans to address this in the near future. |
2019-05-08 10:54:00 -0500 | commented answer | Transitioning PNNL prototype IDF files to EnergyPlus 9.1.0? @mike765 you will need to install energyplus version 8.9 and use the version updater that comes with it. Then use versio |
2019-05-06 16:05:18 -0500 | received badge | ● Teacher (source) |
2019-05-03 18:47:29 -0500 | answered a question | Transitioning PNNL prototype IDF files to EnergyPlus 9.1.0? I see that version 9.1.0 has trouble transitioning some older version EnergyPlus Files. But the transition works fine wi |
2019-04-12 09:39:52 -0500 | commented answer | How to determine custom chiller performance curves with correct coefficients? What should we do for the partload ratio curve EIRFPLR. Also can the chilled water supply temperature remain constant he |
2019-04-02 09:14:37 -0500 | asked a question | Hot water loop load reset Hot water loop load reset What is the best way to simulate a Loads reset option so as to supply at the lowest temperatur |
2018-12-06 16:16:23 -0500 | asked a question | Monthly cooling coil sensible outputs. Monthly cooling coil sensible outputs. I am trying to obtain the monthly sensible cooling coil energy for the cooling co |
2018-11-08 09:32:15 -0500 | marked best answer | Pump head influence on cooling load If we have the pump "Fraction of Motor Inefficiencies to the Fluid Stream" set to 0, why would the pump head have an effect on the cooling load. In the attached, energy plus version 9, test file that uses purchased cooling the "cooling load" changed from 1,018,159 kBtu to 990,412 kBtu . The only thing I changed was to zero out the pump head. |
2018-11-07 10:54:19 -0500 | commented answer | Pump head influence on cooling load From the manual: ShaftPower = PumpPower * PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower) |
2018-11-07 08:36:53 -0500 | commented answer | Pump head influence on cooling load From the manual: ShaftPower = PumpPower * PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower) |
2018-11-07 07:33:49 -0500 | commented answer | Pump head influence on cooling load From the manual: ShaftPower = PumpPower * PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower) |
2018-11-07 07:33:35 -0500 | commented answer | Pump head influence on cooling load From the manual: ShaftPower = PumpPower PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower) |
2018-11-07 07:33:17 -0500 | commented answer | Pump head influence on cooling load From the manual: ShaftPower = PumpPower PumpMotorEfficiency PumpHeatToFluid = ShaftPower + (PumpPower - ShaftPower) * |
2018-11-06 14:41:13 -0500 | asked a question | Pump head influence on cooling load Pump head influence on cooling load If we have the pump "Fraction of Motor Inefficiencies to the Fluid Stream" set to 0, |
2018-10-15 08:54:12 -0500 | commented answer | Specifiying cooling coil and baseboard heater capacity So the only way to ensure the cooling coil capacity matches with a predetermined system size is to make sure that the lo |
2018-10-12 10:05:11 -0500 | asked a question | Specifiying cooling coil and baseboard heater capacity Specifiying cooling coil and baseboard heater capacity The Coil:Cooling:Water does not seem have a way specify the capac |
2018-08-16 08:28:31 -0500 | received badge | ● Enthusiast |
2018-08-10 11:16:46 -0500 | asked a question | AirLoopHVAC:UnitaryHeatCool application for single zone AirLoopHVAC:UnitaryHeatCool application for single zone To model a constant volume system when would I choose a cav syst |
2018-01-22 14:55:54 -0500 | received badge | ● Citizen Patrol (source) |
2017-12-15 09:40:12 -0500 | commented answer | Fan power accounting for a DOAS system with DCV Thanks for your advice. Here is what appears to be working right: Use VAV fan system for the DOAS. Specify the demand |
2017-12-15 09:39:09 -0500 | commented answer | Fan power accounting for a DOAS system with DCV Thanks for your advice. Here is what appears to be working right: 1. Use VAV fan system for the DOAS 2. Specify the de |
2017-12-15 09:33:35 -0500 | commented answer | Fan power accounting for a DOAS system with DCV Thanks for your advice. Here is what I did and appears to be working right. 1) Use VAV fan system for the DOAS 2) Speci |
2017-11-30 11:38:37 -0500 | edited question | Fan power accounting for a DOAS system with DCV Fan power accounting for a DOAS system with DCV It appears that DOAS system with DCV acts as a constant volume system an |
2017-11-29 10:17:56 -0500 | edited question | Fan power accounting for a DOAS system with DCV Fan power accounting for a DOAS system with DCV It appears that DOAS system with DCV acts as a constant volume system an |
2017-11-29 10:16:23 -0500 | edited question | Fan power accounting for a DOAS system with DCV Fan power accounting for a DOAS system with DCV It appears that DOAS system with DCV acts as a constant volume system an |
2017-11-29 09:25:49 -0500 | asked a question | Fan power accounting for a DOAS system with DCV Fan power accounting for a DOAS system with DCV It appears that DOAS system with DCV acts as a constant volume system an |
2017-11-20 14:01:20 -0500 | asked a question | SolarCollector performance data SolarCollector performance data The solar Collector performance data listed in SolarCollector.idf dataset do not appear |
2017-10-20 09:27:18 -0500 | commented answer | IDFVersionUpdater using commandline Looking to run IDFVersionUpdater from the "commandline" and automate the process for repeated usage (whenever I export a |
2017-10-20 09:26:52 -0500 | commented answer | IDFVersionUpdater using commandline Looking to run IDFVersionUpdater from the "commandline" and automate the process for repeated usage (whenever I export a |
2017-10-20 07:37:44 -0500 | commented question | IDFVersionUpdater using commandline running python on windows. |
2017-10-20 07:26:41 -0500 | commented answer | IDFVersionUpdater using commandline So essentially we would need to call each Transition-VA-B-C-to-D-E-F.exe sequentially for each intermediate versions if |
2017-10-19 17:20:18 -0500 | edited question | IDFVersionUpdater using commandline IDFVersionUpdater using commandline I have multiple idf files in version 8.4 that I want to update to version 8.8. Doing |
2017-10-19 17:19:52 -0500 | asked a question | IDFVersionUpdater using commandline IDFVersionUpdater using commandline I have multiple idf files in version 8.4 that I want to update to version 8.8. Doing |
2017-08-16 15:43:28 -0500 | commented answer | Designbuilder/EnergyPlus Relief fan @Raghu, question is about modeling a relief fan not about modeling economizer. The return fan on the AHU moves the retur |
2017-08-11 07:58:44 -0500 | edited question | Designbuilder/EnergyPlus Relief fan Designbuilder/EnergyPlus Relief fan How do I setup a relief fan on the AHU in designbuilder or energyplus. The fan would |
2017-08-11 07:58:01 -0500 | asked a question | Designbuilder/EnergyPlus Relief fan Designbuilder/EnergyPlus Relief fan Is it possible to setup a relief fan on the AHU in designbuilder or energyplus. The |
2017-07-11 08:46:50 -0500 | marked best answer | PackagedTerminalAirConditioner prevent Outdoor air during night cycle I am setting up a PackagedTerminalAirConditioner to run on constant fan during the day and cycle the fan at night. The system also provides outside air and looking to close the outside air dampers when the fan cycles at night. How could I achieve this? The setup I have below does cycle the fan at night but also brings in outside air during night fan cycling. |
2017-07-07 16:30:25 -0500 | edited question | PackagedTerminalAirConditioner prevent Outdoor air during night cycle PackagedTerminalAirConditioner prevent Outdoor air during night cycle I am setting up a PackagedTerminalAirConditioner t |
2017-07-07 16:28:33 -0500 | asked a question | PackagedTerminalAirConditioner prevent Outdoor air during night cycle PackagedTerminalAirConditioner prevent Outdoor air during night cycle I am setting up a PackagedTerminalAirConditioner t |
2016-11-07 17:18:02 -0500 | commented answer | Constant volume system, design temperature influence. The two models are Identical except for the change in the zone sizing temperature. There is no cooling in the model. I do not know why it would control to different temperatures in either case. Maybe there is some numerical instability and there is some impact as to what end of the deadband it is controlled to. A small change may be acceptable. But a 7% change does seem quite high, Would you agree. |
2016-11-07 09:45:29 -0500 | commented answer | Constant volume system, design temperature influence. Sorry, I don't understand what your answer intends to convey. Why is anything other than the fan power changing. To your point about improbable model, I originally had a proper LEED model with heatpump heating and cooling. Found the savings jump 10% with changes just to the zone sizing temperature. To debug the same I created a very simple electric heating only model to minimize influence of other parameters. Moreover, Why should it matter weather the model is probable or not? |
2016-10-31 08:51:22 -0500 | commented question | Constant volume system, design temperature influence. @Tian, As I indicated I zeroed out the fan energy. the outputs attached indicate no fan energy consumed. For some reason there is a 7% change in the heating subcategory. |