2017-06-05 13:39:17 -0500 answered a question Modeling branch and loop pump in OS 2.1

Hi Matt,I modeled my loop as below: If I remembers correctly that old version does support pump at branch. Thank yo

2017-06-05 10:32:05 -0500 asked a question Modeling branch and loop pump in OS 2.1

Modeling branch and loop pump in OS 2.1 Hi guys. I am modeling a HW loop with pump in branch and loop, and the error msg

2016-12-06 11:22:38 -0500 answered a question Severe error caused by Controller Mechanical Ventilation (OpenStudio 1.5.0)

Also, in my case I found out if you forgot to assign a space type for the zone,the same error would appear as well.

2016-06-04 16:25:50 -0500 answered a question Error detected in Object=SETPOINTMANAGER:SINGLEZONE:REHEAT

The error message means your airloop is not controlling any zones. Go back the HVAC tab and go through each airloop for insanity check.

2016-06-04 15:10:45 -0500 received badge  Teacher (source)
2016-06-04 14:28:04 -0500 answered a question How to change Air Loop Name?

Go to the HVAC system tab and choose on the airloop you wanna change, click on the center line and you'll see on the top is the right hand side there is airloop default name for you the change.

2016-04-18 10:56:23 -0500 received badge  Enthusiast
2016-02-08 18:27:30 -0500 commented answer How to model high bay area with large overhead door?

Thanks Julien. That helps a lot.

2016-02-08 11:52:19 -0500 received badge  Autobiographer
2016-02-05 17:12:31 -0500 asked a question How to model high bay area with large overhead door?

Hi all,

I am modeling a building that have large overhead doors in high bay area in OpenStudio. How am I gonna define the overhead door in construction and any suggestion of modeling high bay area? The area included many high pressure water guns which powered by compressed air system.

Any suggestion helps.

Thanks

2015-07-22 12:14:56 -0500 received badge  Scholar (source)
2015-07-22 10:31:02 -0500 commented answer What's the difference between "'Facility" and "Building" in EnergyPlus?

Thanks, Eric! Great help!

2015-07-22 10:28:01 -0500 received badge  Supporter (source)
2015-07-22 10:23:28 -0500 received badge  Student (source)
2015-07-22 10:22:29 -0500 asked a question What's the difference between "'Facility" and "Building" in EnergyPlus?

In the energy meter of the standard report electricity showed the results for "facility" and "building", the gap are pretty small. I wonder that's the differences?

Thanks