2024-03-18 09:52:44 -0500 | commented answer | Setting up Ruby Environment for Measures in Win 10
is Ruby 3.x supported? @Redline The current plan is for OpenStudio 3.8 (planned release: May 17, 2024) to include ruby 3.2.2. |
2024-03-15 09:41:45 -0500 | received badge | ● Rapid Responder (source) |
2024-03-15 09:41:45 -0500 | answered a question | I get error: An unhandled exception has occurred. The gbXML appears to have a date with the year set as 1, which doesn't make sense since it should be 2024 or similar. Yo |
2024-03-14 08:33:39 -0500 | commented answer | Temperature control and CO2 control (EMS SCRIPT) not working together for Natural Ventilation Ah, right. Glad you got it working. I only used AND because you had that in your original program and I’d didn’t think t |
2024-03-13 09:45:29 -0500 | received badge | ● Rapid Responder (source) |
2024-03-13 09:45:29 -0500 | answered a question | Temperature control and CO2 control (EMS SCRIPT) not working together for Natural Ventilation You can't have an EMS line that starts with AND. The EMS program should be: EnergyManagementSystem:Program, CO2_S |
2024-03-12 08:44:51 -0500 | commented question | FindRootSimpleController Duplicate of https://unmethours.com/question/98460/findrootsimplecontroller/ |
2024-03-11 15:15:19 -0500 | received badge | ● Rapid Responder (source) |
2024-03-11 15:15:19 -0500 | answered a question | ** Severe ** vector too long It's possible you are encountering an error that occurs when a zone or space has no surfaces; see here. There are some w |
2024-03-08 14:19:25 -0500 | commented question | Unable to determine fan air flow rate Error I suggest opening an issue at https://github.com/NREL/EnergyPlus/issues. I'm not seeing any other users that have hit th |
2024-03-08 10:58:23 -0500 | edited answer | Plant Component EMS On/Off - Openstudio First of all, you should not be using commas and semicolons in the addLine methods -- OpenStudio will do that for you. |
2024-03-08 10:57:46 -0500 | answered a question | Plant Component EMS On/Off - Openstudio First of all, you should not be using commas and semicolons -- OpenStudio will do that for you. Also, I think you want |
2024-03-08 10:57:46 -0500 | received badge | ● Rapid Responder (source) |
2024-03-05 18:03:48 -0500 | commented question | Crashing Issue in OpenStudio When Accessing Thermal Zone Tab Linking to the GitHub issue you created: https://github.com/openstudiocoalition/OpenStudioApplication/issues/686 |
2024-03-04 13:16:39 -0500 | commented answer | Can we use epjson as input file to run energy simulation? The -r is an optional argument that can be used; I agree that it doesn't run the simulation. I'll remove it above since |
2024-03-04 13:16:16 -0500 | edited answer | Can we use epjson as input file to run energy simulation? If you call the EnergyPlus CLI with the -h flag, it will display all options: C:\EnergyPlusV22-1-0\energyplus.exe -h En |
2024-03-04 13:15:39 -0500 | commented answer | Can we use epjson as input file to run energy simulation? The -r is an optional argument that can be used and I agree that it doesn't run the simulation. I'll remove it above sin |
2024-02-28 10:27:57 -0500 | answered a question | OS Measures: Repository of delted ones (older Versions of OS)? That measure lives in this repository: https://github.com/NREL/openstudio-aedg-gem According to the list of releases, v |
2024-02-28 10:27:57 -0500 | received badge | ● Rapid Responder (source) |
2024-02-25 11:34:50 -0500 | edited answer | HVAC IdealLoadsAirSystem output metric DistrictHeating was renamed to DistrictHeatingWater in EnergyPlus 23.2. You can confirm this by running the simulation a |
2024-02-25 11:34:11 -0500 | edited answer | HVAC IdealLoadsAirSystem output metric DistrictHeating was renamed to DistrictHeatingWater in EnergyPlus 23.2. You can confirm this by running the simulation a |
2024-02-25 11:33:34 -0500 | answered a question | HVAC IdealLoadsAirSystem output metric DistrictHeating was renamed to DistrictHeatingWater in EnergyPlus 23.2. You can confirm this by running the simulation a |
2024-02-25 11:33:34 -0500 | received badge | ● Rapid Responder (source) |
2024-02-25 11:12:49 -0500 | commented question | HVACTemplate:Zone:IdealLoadsAirSystem vs ZoneHVAC:IdealLoadsAirSystem meter options Duplicate of https://unmethours.com/question/98303/hvac-idealloadsairsystem-output-metric/ |
2024-02-22 18:55:52 -0500 | edited question | CO2 Gas Cooler fan in EP error(s) in source code CO2 Gas Cooler fan in EP error(s) in source code Hello to anyone reading this post. I am currently building a Co2 transc |
2024-02-22 18:55:27 -0500 | edited question | CO2 Gas Cooler fan in EP error(s) in source code CO2 Gas Cooler fan in EP error(s) in source code Hello to anyone reading this post. I am currently building a Co2 transc |
2024-02-17 06:42:04 -0500 | edited answer | How do you make your heating/cooling thermostat follow your occupancy schedule? You can set the “Availability Schedule Name” of your HVAC system to be the same as your occupancy “Number of People Sche |
2024-02-17 06:41:03 -0500 | answered a question | How do you make your heating/cooling thermostat follow your occupancy schedule? You can set the “Availability Schedule Name” of your HVAC system to be the same as your occupancy “Number of People Sche |
2024-02-05 09:32:40 -0500 | commented question | The surface has an edge that is either not an edge on another surface or is an edge on three or more surfaces See https://unmethours.com/question/33919/zone-within-a-zone/ |
2024-02-01 09:23:45 -0500 | commented question | Minimum Indoor Temperature in ZoneVentilation:WindandStackOpenArea does not work The current issue related to this can be found here. |
2024-01-31 09:34:23 -0500 | received badge | ● Rapid Responder (source) |
2024-01-31 09:34:23 -0500 | answered a question | How to set Heating Design Temperature The general answer is that those OpenStudio-HPXML inputs are not currently exposed to ResStock. In order for an OpenStud |
2024-01-31 09:26:13 -0500 | answered a question | Time of Peak is not in Timestep increments There are two timesteps in EnergyPlus, the Zone timestep (which is the user input) and a System timestep (which is not). |
2024-01-31 09:26:13 -0500 | received badge | ● Rapid Responder (source) |
2024-01-31 08:35:56 -0500 | commented question | Water source VRF curve Duplicate of https://unmethours.com/question/98111/water-source-vrf-curve/ |
2024-01-31 08:35:31 -0500 | commented question | Water source VRF curve Duplicate of https://unmethours.com/question/98111/water-source-vrf-curve/ |
2024-01-29 09:26:23 -0500 | commented question | How to fix this error? vector too long Please provide your IDF file via e.g. Dropbox or Google Drive. |
2024-01-24 14:55:26 -0500 | commented question | Detailed Performance Data heating and cooling Note that the ability to specify detailed performance data with equipment autosizing, which is nearly always what you'd |
2024-01-24 14:54:50 -0500 | commented question | Detailed Performance Data heating and cooling Note that the ability to specify detailed performance data with equipment autosizing, which is nearly always what you'd |
2024-01-23 09:56:28 -0500 | commented answer | Observing Phase Change Material (PCM) State Changes in DesignBuilder Simulation Ah, I think you're right. I was thrown off by the fact that these output variables show up in the .rdd file when you run |
2024-01-22 17:44:08 -0500 | answered a question | Observing Phase Change Material (PCM) State Changes in DesignBuilder Simulation EnergyPlus has a couple outputs (CondFD Phase Change State and CondFD Phase Change Previous State) for phase change mate |
2024-01-22 14:40:41 -0500 | commented question | pyenergyplus.api define weather Duplicate of https://unmethours.com/question/98039/pyenergyplusapi-define-weather/ |
2024-01-17 11:12:49 -0500 | answered a question | Natural ventilation - BEopt Building orientation does not affect the natural ventilation. The "Cooling months only, 7days/week" option means that wi |
2024-01-16 12:20:31 -0500 | received badge | ● Rapid Responder (source) |
2024-01-16 12:20:31 -0500 | answered a question | Internal load assumptions - BEopt BEopt calculates internal gains from plug loads, major appliances, lighting, water heater tank losses, etc., all of whic |
2024-01-11 16:56:15 -0500 | answered a question | Adding a ASHP to residential model Assuming the ducted mini-split and furnace are sharing the same distribution system and blower, you can model the mini-s |
2024-01-09 08:03:04 -0500 | commented answer | How can i use EMS to change the transmittance of a movable insulation? Sorry, I didn’t realize E+ has a separate movable insulation object. I will remove my answer. |
2024-01-08 17:35:00 -0500 | commented answer | How set infiltration rate (ACH) in AFN model? Nice idea. Agreed that the interaction between infiltration and natural ventilation is not important, but there are othe |
2024-01-08 13:09:52 -0500 | answered a question | How can i use EMS to change the transmittance of a movable insulation? See the EMS example in the EnergyPlus documentation on how to swap constructions during the simulation runtime. |
2024-01-08 13:09:52 -0500 | received badge | ● Rapid Responder (source) |