2022-04-19 23:11:48 -0500 | received badge | ● Popular Question (source) |
2015-09-01 02:15:12 -0500 | commented answer | How to control the Outdoor Air flow rate in EnergyPlus? I test my model again. I find the maximum supply flow rate can reach 5.1 only, so no matter how I set the OA controller the outdoor air flow rate reach 5.1 only. If the CAV system can realize my purpose? |
2015-08-29 02:26:31 -0500 | commented answer | How to control the Outdoor Air flow rate in EnergyPlus? @Annie Marston Thank you! I have try my best to find the solver through your answer, but I don`t reach my purpose. |
2015-08-28 09:02:54 -0500 | asked a question | How to control the Outdoor Air flow rate in EnergyPlus? I built a model with the CAV system. The outdoor air flow rate is 20m3/h-person on the cooling and heating season. The transition season is set to the full outdoor air(about 5.1m3/s), the minmum outdoor air fraction is 1, but the indoor temperature is too high yet. So I want to know how can I make the outdoor air folw rate improve to the AHU Fan maxmum flow rate(9.685m3/s). |
2015-08-11 04:55:01 -0500 | commented question | Why the count of the HeaderedPump is always one in EnergyPlus? @MJWitte Thank you very much! I will send to your e-mail. |
2015-08-07 02:35:12 -0500 | commented answer | Why the count of the HeaderedPump is always one in EnergyPlus? Ok!Thank you for your attention! |
2015-08-07 02:35:12 -0500 | received badge | ● Commentator |
2015-08-06 22:57:24 -0500 | answered a question | Why the count of the HeaderedPump is always one in EnergyPlus? The following is the idf and eso.@MJWitte |
2015-08-06 09:24:43 -0500 | asked a question | Why the count of the HeaderedPump is always one in EnergyPlus? My chilled water system contains a The following is the idf and eso @MJWitte |
2015-07-16 01:02:16 -0500 | commented answer | How to set nightventilation in EnergyPlus I will try the EMS.I hope the outdoor air flow fraction can stay 1 at night. |
2015-07-15 21:14:21 -0500 | commented answer | How to set nightventilation in EnergyPlus Thanks your answer! Your answer can solve my question perfectly. But another way can solve the question I think.If we can use the "ZoneVentilation:DesignFolwRate" object replace the "AvailabilityManager:NightVentilation" object. So your suggestion? |
2015-07-15 21:04:24 -0500 | commented answer | How to set nightventilation in EnergyPlus Ok! Thank you very much. |
2015-07-13 21:34:43 -0500 | commented answer | How to set nightventilation in EnergyPlus @Kyle Benne Thank you!I think you are right but my model is right. The both fans use the same availability and the night ventilation manager reference that schedule.Does your model has two fans in OpenStudio? if they can work correctly? |
2015-07-13 21:33:04 -0500 | answered a question | How to set nightventilation in EnergyPlus Thank you!I think you are right but my model is right. The both fans use the same availability and the night ventilation manager reference that schedule.Does your model has two fans in OpenStudio? if they can work correctly? |
2015-07-08 09:22:54 -0500 | asked a question | How to set nightventilation in EnergyPlus The system is an constant volume model.Each system have a supply and a return fan. I want to use the AvailablityManager:NightVentilation but I don`t know why the fan not work at night.When I delete the return fan the supply can work correctly. So I want know which method can make the supply fan and return fan work at night. Thank you! |
2015-07-08 02:47:04 -0500 | commented answer | How to control the temperature of hot water on the heating coil in EnergyPlus Thank you very much! The system of my model use a ConstanPump and I find the water flow rate of the bypass is too big so must heat energy loss. The coil model is Coil:Heating:Water.I put a setpoint use the SetpointManager:Schedule but the temperature of outlet still 25℃. |
2015-07-06 03:45:10 -0500 | asked a question | How to control the temperature of hot water on the heating coil in EnergyPlus I want know if we can control the temperature about the heating coil outlet . I use the DistrictHeating as the heat source .The supply heat water temperature is 60 ℃,but the heating coil outlet temperature is only about 25 ℃. So I think the outlet temperature is too low. |
2015-06-10 08:05:26 -0500 | commented answer | I find a severe error in energy plus and don't understand it! OK, thank you very much! I think I have solved the problem with your help. |
2015-06-09 08:54:49 -0500 | commented answer | I find a severe error in energy plus and don't understand it! I think the comment don`t post a text file. |
2015-06-09 02:06:00 -0500 | received badge | ● Scholar (source) |
2015-06-05 05:14:26 -0500 | commented answer | I find a severe error in energy plus and don't understand it! @Annie Marston Ok thanks! I think you are right! But I don`t know how to post the error file. |
2015-06-03 21:14:56 -0500 | commented question | I find a severe error in energy plus and don't understand it! I will. Thank you! |
2015-06-03 20:45:17 -0500 | edited question | I find a severe error in energy plus and don't understand it! I am getting the error from "Errors" button but don't know what they mean and how to solve them: 1.I have set the plantloop Availability Manager so the cooling coil don`t work On March 6. 2.The controller action=Reverse and I simulate the idf document when I change the controller action=Normal but the error did not change. Thanks a lot! |
2015-06-03 20:44:06 -0500 | received badge | ● Editor (source) |